Enclosed Starter

Product Dimensions

Width icon

Width78 mm

Height icon

Height160 mm

Depth icon

Depth108 mm

See full specifications

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range

TeSys

Product or component type

enclosed DOL starter

Device application

standard

Warranty

18 months

Physical

Control type

  • push-button start green I
  • push-button stop/reset red O
    • Local signalling

      operating: LED (yellow)

      Width

      78 mm

      Height

      160 mm

      Depth

      108 mm

      Net weight

      0.6 kg

      IP degree of protection

      IP65 conforming to IEC 60529

      Standards

      IEC 60947-4-1

      Ambient air temperature for operation

      -5-40 °C

      Environmental characteristic

      standard environment

      REACh free of SVHC

      Yes

      EU RoHS Directive

      Compliant

      Toxic heavy metal free

      Yes

      Mercury free

      Yes

      RoHS exemption information

      Yes

      China RoHS Regulation

      X

      Material

      Device composition

    • contactor
    • earth terminal
    • neutral terminal
    • thermal overload relay
      • Material

        ABS (acrylonitrile butadiene-styrene)

        Others

        Product name

        TeSys LE

        Device short name

        LE1M

        Utilisation category

        AC-3

        Thermal protection adjustment range

        1.2-1.8 A

        Motor power kW

      • 0.25 kW at 240 V AC 50/60 Hz
      • 0.55 kW at 415 V AC 50/60 Hz
      • 0.25 kW at 220/230 V AC 50/60 Hz
      • 0.55 kW at 380/400 V AC 50/60 Hz
        • [Uc] control circuit voltage

          415 V AC 50/60 Hz

          Cable entry number

        • 2 ISO20 top
        • 2 Pg 16 bottom
        • 2 ISO25 top
        • 2 Pg 13 top
        • 2 Pg 21 top
        • 2 ISO20 bottom
        • 2 ISO25 bottom
        • 2 Pg 13 bottom
        • 2 Pg 21 bottom
        • 2 Pg 16 top
          • Compatibility code

            LE1M

            Unit Type of Package 1

            PCE

            Number of Units in Package 1

            1

            Package 1 Weight

            575 g

            Package 1 Height

            8 cm

            Package 1 width

            11.7 cm

            Package 1 Length

            16.5 cm

            Unit Type of Package 2

            S02

            Number of Units in Package 2

            6

            Package 2 Weight

            3.754 kg

            Package 2 Height

            15 cm

            Package 2 width

            30 cm

            Package 2 Length

            40 cm

            WEEE

            The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
            Show all specifications

            Documents & downloads

            hide show
            Filter items
            • All

            • CAD Files and Packs

            • Product Brochures

            • Technical Data Catalogues

            • Installation Instruction

            • Declaration of Conformity

            Frequently Asked Questions

            hide show

            Is there a LE1M35N705 alternative or can coil be swapped out

             The part codes you need is LE1D12N7 + LRD06

            What is the part number for an replacement overload , 3.7-5.5amp , for the LE1M35N712?

            The part number for an replacement overload , 3.7-5.5amp , for the LE1M35N712 is - LR2K0312
            For further information visit link below:-
            https://www.schneider-electric.com.au/en/search/LR2K0312
             

            What is the weight of a LE1M35U705

             0.6 kg

            What is the LE1M35U705 made of

            self extinguishing ABS

            What is the IP rating of a LE1M35U705

            The rating is  IP 65

            What is the DOL to suit the thermal overload LR2K0321?

            The DOL To suit the thermal overloadLR2K0321 is:
            LE1M35U721 for a 240V application or LE1M35N721 for a 440V application.

            What is the operational Temperature for a LE1M35U705

             The operational temperature is  -5 to 40° Degrees celsius

            What are the dimensions of a LE1M35U705

             160 x 78 x 108mm (H x W x D)

            What is the part code for a DOL Starter 1P 2.2kW 12-16A Overload

             Use a LE1M35U722 starter

            What are the dimensions for a Model K DOL non reversing starter - LE1M35U7?

            The dimensions for a Model K DOL non reversing starter - LE1M35U7 are - W78mm x H160mm x D108mm

            For further information , visit link below:-
            https://www.schneider-electric.com.au/en/search/LE1M35U5
            User-added image

             

            What is the cable entry for a LE1M35U705

            2 x 13mm PG at bottom and top
            2 x 20mm ISO at bottom and top
            2 x 21mm PG at bottom and top
            2 x 25mm ISO at bottom and top

            Motor power in kW of a LE1M35U705

            0.25 kW at 415 V AC 50/60 Hz
            0.25 kW at 380...400 V AC 50/60 Hz
            0.12 kW at 240 V AC 50/60 Hz
            0.12 kW at 220...230 V AC 50/60 Hz
             
            Show More