Quantcast

TeSys D Star Delta Starter, 3 x 3P (3 NO), 32A, 24VAC Coil

TeSys D Star Delta Starter, 3 x 3P (3 NO), 32A, 24VAC Coil

TeSys D Star Delta Starter, 3 x 3P (3 NO), 32A, 24VAC Coil

Item Number: LC3D32AB7

Retail
$3,251.23
RRP (Inc. GST)

Product Dimensions

Width icon

Width166 mm

Height icon

Height124 mm

Depth icon

Depth149 mm

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

TeSys D

Range

TeSys

Product or component type

star delta starter

Sustainable offer status

Green Premium product

Warranty

18 months

Physical

Device presentation

pre-wired

[Ue] rated operational voltage

power circuit: <= 690 V AC 25...400 Hz

[Ie] rated operational current

32 A (at <60 °C) at <= 440 V AC AC-3 for power circuit

Electrical durability

1.65 Mcycles 32 A AC-3 at Ue <= 440 V

Provided equipment

protective cover

Mounting support

plate

Standards

  • UL 508
  • EN 60947-5-1
  • IEC 60947-4-1
  • CSA C22.2 No 14
  • IEC 60947-5-1
  • EN 60947-4-1
    • Product certifications

    • DNV
    • RINA
    • GOST
    • CCC
    • CSA
    • UL
    • LROS (Lloyds register of shipping)
    • BV
    • GL
      • Connections - terminals

      • control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end
      • power circuit: screw clamp terminals 2 1.5-6 mm² - cable stiffness: flexible with cable end
      • power circuit: screw clamp terminals 1 1.5-10 mm² - cable stiffness: solid without cable end
      • power circuit: screw clamp terminals 2 2.5-10 mm² - cable stiffness: solid without cable end
      • control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end
      • control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end
      • control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end
      • control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end
      • control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end
      • power circuit: screw clamp terminals 1 2.5-10 mm² - cable stiffness: flexible without cable end
      • power circuit: screw clamp terminals 2 2.5-10 mm² - cable stiffness: flexible without cable end
      • power circuit: screw clamp terminals 1 1-10 mm² - cable stiffness: flexible with cable end
        • Mechanical durability

          15 Mcycles

          Width

          166 mm

          Height

          124 mm

          Depth

          149 mm

          Net weight

          2.03 kg

          Insulation resistance

          > 10 MOhm for signalling circuit

          IP degree of protection

          IP20 front face conforming to IEC 60529

          Ambient air temperature for storage

          -60-80 °C

          Ambient air temperature for operation

          -40-70 °C at Uc

          REACh Regulation

          Free of Substances of Very High Concern above the threshold

          REACh free of SVHC

          Yes

          EU RoHS Directive

          Compliant

          Toxic heavy metal free

          Yes

          Mercury free

          Yes

          RoHS exemption information

          Yes

          China RoHS Regulation

           Pro-active China RoHS declaration (out of China RoHS legal scope)

          Environmental Disclosure

          ENVPEP1501004EN

          Circularity Profile

          ENVEOLI1501004EN

          Others

          Product name

          TeSys D

          Device short name

          LC3D

          Contactor application

          motor control

          Utilisation category

          AC-3

          Poles description

          3 x 3P

          Pole contact composition

          3 x 3 NO

          Motor power kW

        • 15 kW at 220/230 V AC 50/60 Hz
        • 25 kW at 380/400 V AC 50/60 Hz
        • 30 kW at 415 V AC 50/60 Hz
        • 30 kW at 440 V AC 50/60 Hz
          • Control circuit type

            AC at 50/60 Hz

            [Uc] control circuit voltage

            24 V AC 50/60 Hz

            Auxiliary contact composition

            1 NC for KM1 star contactor

            [Uimp] rated impulse withstand voltage

            6 kV conforming to IEC 60947

            Overvoltage category

            III

            Interlocking type

            mechanical

            Tightening torque

          • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
          • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
          • power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
          • power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver Philips No 2
            • Maximum operating rate

              30 cyc/h 60 °C

              Starting time

              30 s

              Coil technology

              without built-in suppressor module

              Control circuit voltage limits

            • drop-out: 0.3...0.6 Uc at 50/60 Hz (at <60 °C)
            • operational: 0.8...1.1 Uc at 50 Hz (at <60 °C)
            • operational: 0.85...1.1 Uc at 60 Hz (at <60 °C)
              • Inrush power in VA

              • 70-70 VA 60 Hz cos phi 0.75 (at 20 °C)
              • 70-70 VA 50 Hz cos phi 0.75 (at 20 °C)
                • Hold-in power consumption in VA

                • 7.5-7.5 VA 60 Hz cos phi 0.3 (at 20 °C)
                • 7-7 VA 50 Hz cos phi 0.3 (at 20 °C)
                  • Heat dissipation

                    2-3 W at 50/60 Hz

                    Auxiliary contacts type

                  • mechanically linked conforming to IEC 60947-5-1 3 x 1 NO + 1 NC
                  • mirror contact conforming to IEC 60947-4-1 3 x 1 NC
                    • Signalling circuit frequency

                      25...400 Hz

                      Minimum switching current

                      5 mA for signalling circuit

                      Switching voltage

                      17 V for signalling circuit

                      Non-overlap time

                    • 1.5 ms on de-energisation between NC and NO contact
                    • 1.5 ms on energisation between NC and NO contact
                      • Power range

                      • 15-25 kW at 380-440 V 3 phases
                      • 15-25 kW at 200-240 V 3 phases
                      • 30-50 kW at 380-440 V 3 phases
                        • Motor starter type

                          star delta starter

                          Contactor coil voltage

                          24 V AC standard

                          Protective treatment

                          TH conforming to IEC 60068-2-30

                          Pollution degree

                          3

                          Operating altitude

                          3000 m without derating

                          Fire resistance

                          850 °C conforming to IEC 60695-2-1

                          Flame retardance

                          V1 conforming to UL 94

                          Mechanical robustness

                        • vibrations contactor open: 2 Gn, 5...300 Hz
                        • vibrations contactor closed: 4 Gn, 5...300 Hz
                        • shocks contactor closed: 15 Gn for 11 ms
                        • shocks contactor open: 8 Gn for 11 ms
                          • Unit Type of Package 1

                            PCE

                            Number of Units in Package 1

                            1

                            Package 1 Weight

                            1.725 kg

                            Package 1 Height

                            16 cm

                            Package 1 width

                            17.5 cm

                            Package 1 Length

                            23 cm

                            Unit Type of Package 2

                            S04

                            Number of Units in Package 2

                            6

                            Package 2 Weight

                            11.181 kg

                            Package 2 Height

                            30 cm

                            Package 2 width

                            40 cm

                            Package 2 Length

                            60 cm

                            WEEE

                            The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

                            PVC free

                            Yes
                            Show all specifications

                            Documents & downloads

                            hide show
                            Filter items
                            • All

                            • Product Brochures

                            • End of Life Manual

                            • eTechPub