Product or component type
star delta starter
Contactor application
motor control
Utilisation category
AC-3
Device presentation
pre-wired
Pole contact composition
3 x 3 NO
[Ue] rated operational voltage
power circuit: <= 690 V AC 25...400 Hz
[Ie] rated operational current
12 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
Motor power kW
11 kW at 380/400 V AC 50/60 Hz11 kW at 415 V AC 50/60 Hz11 kW at 440 V AC 50/60 Hz5.5 kW at 220/230 V AC 50/60 Hz
Control circuit type
AC at 50/60 Hz
[Uc] control circuit voltage
110 V AC 50/60 Hz
Auxiliary contact composition
1 NC for KM1 star contactor
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947
[Ui] rated insulation voltage
power circuit: 690 V conforming to IEC 60947-4-1power circuit: 600 V CSA certifiedpower circuit: 600 V UL certifiedsignalling circuit: 690 V conforming to IEC 60947-1signalling circuit: 600 V CSA certifiedsignalling circuit: 600 V UL certified
Electrical durability
2 Mcycles 12 A AC-3 at Ue <= 440 V
Provided equipment
protective cover
Interlocking type
mechanical
Standards
EN 60947-5-1IEC 60947-4-1EN 60947-4-1UL 508CSA C22.2 No 14IEC 60947-5-1
Product certifications
CCCRINAGLLROS (Lloyds register of shipping)DNVBVULGOSTCSA
Connections - terminals
power circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable endcontrol circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable endcontrol circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable endcontrol circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable endpower circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable endpower circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable endpower circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable endpower circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable endpower circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable endcontrol circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable endcontrol circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable endcontrol circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end
Tightening torque
power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mmpower circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mmcontrol circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
Mechanical durability
15 Mcycles
Maximum operating rate
30 cyc/h 60 °C
Coil technology
without built-in suppressor module
Control circuit voltage limits
drop-out: 0.3...0.6 Uc at 50/60 Hz (at <60 °C)operational: 0.8...1.1 Uc at 50 Hz (at <60 °C)operational: 0.85...1.1 Uc at 60 Hz (at <60 °C)
Inrush power in VA
70-70 VA 60 Hz cos phi 0.75 (at 20 °C)70-70 VA 50 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA
7.5-7.5 VA 60 Hz cos phi 0.3 (at 20 °C)7-7 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation
2-3 W at 50/60 Hz
Auxiliary contacts type
mechanically linked conforming to IEC 60947-5-1 3 x 1 NO + 1 NCmirror contact conforming to IEC 60947-4-1 3 x 1 NC
Signalling circuit frequency
25...400 Hz
Minimum switching current
5 mA for signalling circuit
Switching voltage
17 V for signalling circuit
Non-overlap time
1.5 ms on de-energisation between NC and NO contact1.5 ms on energisation between NC and NO contact
Power range
4-6 kW at 200-240 V 3 phases7-11 kW at 380-440 V 3 phases
Motor starter type
star delta starter
Contactor coil voltage
110 V AC standard
Insulation resistance
> 10 MOhm for signalling circuit
IP degree of protection
IP20 front face conforming to IEC 60529
Protective treatment
TH conforming to IEC 60068-2-30
Ambient air temperature for storage
-60-80 °C
Ambient air temperature for operation
-40-70 °C at Uc
Operating altitude
3000 m without
Fire resistance
850 °C conforming to IEC 60695-2-1
Flame retardance
V1 conforming to UL 94
Mechanical robustness
vibrations contactor open: 2 Gn, 5...300 Hzvibrations contactor closed: 4 Gn, 5...300 Hzshocks contactor open: 10 Gn for 11 msshocks contactor closed: 15 Gn for 11 ms
Sustainable offer status
Green Premium product
REACh Regulation
Free of Substances of Very High Concern above the threshold
EU RoHS Directive
Compliant
Toxic heavy metal free
Yes
RoHS exemption information
Yes
Environmental Disclosure
ENVPEP080208EN
Circularity Profile
ENVEOLI100418
WEEE
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
California proposition 65
WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.gov