MASTER YOUR CASTLE with your new build or reno project
Enter competition
LC2D65AKUE

LC2D65AKUE

TeSys D Reversing Contactor-3 Pole AC3 <= 440V 65A, 100 - 250V ACDC Coil

LC2D65AKUE
Colour:
Colour: Per UOM Std.
  • 1 PCE
Added to cart
Successfully added, you can view your cart here

Key Features & Specifications

hide show
  • Up to 80% less energy consumption compared to traditional electro mechanical contactor
  • Noise free design
  • Green Premium ecoLabel
  • Direct PLC control for contactors from 40 to 65A
  • High uptime thanks to wide band coil with high resistance to voltage fluctuation
Range of product
TeSys D
Range
TeSys
Product name
TeSys D Green
Product or component type
reversing contactor
Device short name
LC2D
Contactor application
  • motor control
  • resistive load
    • Utilisation category
    • AC-3
    • AC-1
      • Device presentation
        preassembled with reversing power busbar
        Poles description
        3P
        Pole contact composition
        3 NO
        [Ue] rated operational voltage
        power circuit: 690 V AC 25...400 Hz
        [Ie] rated operational current
      • 80 A (at <60 °C) at <= 440 V AC-1 for power circuit
      • 65 A (at <60 °C) at <= 440 V AC-3 for power circuit
        • Motor power kW
        • 18.5 kW at 220...230 V AC 50 Hz
        • 30 kW at 380...400 V AC 50 Hz
        • 37 kW at 415 V AC 50 Hz
        • 37 kW at 440 V AC 50 Hz
        • 37 kW at 500 V AC 50 Hz
        • 37 kW at 660...690 V AC 50 Hz
          • Motor power hp
          • 5 hp at 115 V AC 60 Hz for 1 phase motors
          • 10 hp at 230/240 V AC 60 Hz for 1 phase motors
          • 20 hp at 200/208 V AC 60 Hz for 3 phases motors
          • 20 hp at 230/240 V AC 60 Hz for 3 phases motors
          • 40 hp at 460/480 V AC 60 Hz for 3 phases motors
          • 50 hp at 575/600 V AC 60 Hz for 3 phases motors
            • Control circuit type
            • AC at 50/60 Hz AC/DC electronic
            • DC AC/DC electronic
              • [Uc] control circuit voltage
              • 100...250 V AC 50/60 Hz
              • 100...250 V DC
                • Auxiliary contact composition
                  1 NO + 1 NC
                  [Uimp] rated impulse withstand voltage
                  6 kV conforming to IEC 60947
                  Overvoltage category
                  III
                  [Ith] conventional free air thermal current
                • 10 A (at 60 °C) for signalling circuit
                • 80 A (at 60 °C) for power circuit
                  • Irms rated making capacity
                  • 140 A AC for signalling circuit conforming to IEC 60947-5-1
                  • 250 A DC for signalling circuit conforming to IEC 60947-5-1
                  • 1000 A at 440 V for power circuit conforming to IEC 60947
                    • Rated breaking capacity
                      1000 A at 440 V for power circuit conforming to IEC 60947
                      [Icw] rated short-time withstand current
                    • 100 A - 1 s for signalling circuit
                    • 120 A - 500 ms for signalling circuit
                    • 140 A - 100 ms for signalling circuit
                    • 520 A 40 °C - 10 s for power circuit
                    • 900 A 40 °C - 1 s for power circuit
                    • 110 A 40 °C - 10 min for power circuit
                    • 260 A 40 °C - 1 min for power circuit
                      • Associated fuse rating
                      • 10 A gG for signalling circuit conforming to IEC 60947-5-1
                      • 125 A gG at <= 690 V coordination type 1 for power circuit
                      • 125 A gG at <= 690 V coordination type 2 for power circuit
                        • Average impedance
                          1.5 mOhm - Ith 80 A 50 Hz for power circuit
                          [Ui] rated insulation voltage
                        • power circuit: 690 V conforming to IEC 60947-4-1
                        • signalling circuit: 690 V conforming to IEC 60947-1
                          • Electrical durability
                          • 1.8 Mcycles 57 A AC-3 at Ue <= 440 V
                          • 0.5 Mcycles 80 A AC-1 at Ue <= 440 V
                            • Power dissipation per pole
                            • 9.6 W AC-1
                            • 6.3 W AC-3
                              • Protective cover
                                with
                                Interlocking type
                                mechanical
                                Mounting support
                              • rail
                              • plate
                                • Standards
                                • EN/IEC 60947-4-1
                                • EN/IEC 60947-5-1
                                • UL 60947-4-1
                                • CSA C22.2 No 60947-4-1
                                  • Product certifications
                                  • CCC
                                  • CSA
                                  • EAC
                                  • UL
                                  • KC
                                  • DNV-GL
                                  • LROS (Lloyds register of shipping)
                                    • Connections - terminals
                                    • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end
                                    • control circuit: screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end
                                    • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible with cable end
                                    • control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end
                                    • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²solid
                                    • control circuit: screw clamp terminals 2 cable(s) 1-4 mm²solid
                                    • power circuit: EverLink BTR screw connectors 1 cable(s) 1-35 mm²flexible without cable end
                                    • power circuit: EverLink BTR screw connectors 2 cable(s) 1-25 mm²flexible without cable end
                                    • power circuit: EverLink BTR screw connectors 1 cable(s) 1-35 mm²flexible with cable end
                                    • power circuit: EverLink BTR screw connectors 2 cable(s) 1-25 mm²flexible with cable end
                                    • power circuit: EverLink BTR screw connectors 1 cable(s) 1-35 mm²solid
                                    • power circuit: EverLink BTR screw connectors 2 cable(s) 1-25 mm²solid
                                      • Tightening torque
                                      • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
                                      • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
                                      • power circuit: 8 N.m - on EverLink BTR screw connectors - cable 25-35 mm² hexagonal screw head 4 mm
                                      • power circuit: 5 N.m - on EverLink BTR screw connectors - cable 1-25 mm² hexagonal screw head 4 mm
                                        • Operating time
                                        • 55...65 ms closing
                                        • 20...120 ms opening (date code >= 17221)
                                        • 20...80 ms opening (date code >= 18011)
                                          • Safety reliability level
                                          • B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
                                          • B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
                                            • Mechanical durability
                                              6 Mcycles
                                              Maximum operating rate
                                              3600 cyc/h 60 °C
                                              Coil technology
                                              built-in bidirectional peak limiting
                                              Control circuit voltage limits
                                            • drop-out: <= 0.1 Uc (at 60 °C)
                                            • operational: 0.85...1.1 Uc (at 60 °C)
                                              • Inrush power in VA
                                                18-18 VA 50/60 Hz (at 20 °C)
                                                Inrush power in W
                                                14-14 W at 20 °C
                                                Hold-in power consumption in VA
                                                1.8-1.8 VA (at 20 °C) 50/60 Hz
                                                Hold-in power consumption in W
                                                1.2-1.2 W at 20 °C
                                                Heat dissipation
                                                1.2-1.2 W at 50/60 Hz
                                                Auxiliary contacts type
                                              • type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
                                              • type mirror contact 1 NC conforming to IEC 60947-4-1
                                                • Signalling circuit frequency
                                                  25...400 Hz
                                                  Minimum switching current
                                                  5 mA for signalling circuit
                                                  Minimum switching voltage
                                                  17 V for signalling circuit
                                                  Non-overlap time
                                                • 1.5 ms on de-energisation between NC and NO contact
                                                • 1.5 ms on energisation between NC and NO contact
                                                  • Insulation resistance
                                                    > 10 MOhm for signalling circuit
                                                    Compatibility code
                                                    LC2D
                                                    IP degree of protection
                                                    IP20 front face conforming to IEC 60529
                                                    Protective treatment
                                                    TH conforming to IEC 60068-2-30
                                                    Pollution degree
                                                    3
                                                    Ambient air temperature for operation
                                                    -25-60 °C
                                                    Ambient air temperature for storage
                                                    -60-80 °C
                                                    Permissible ambient air temperature around the device
                                                    -40-70 °C at Uc
                                                    Operating altitude
                                                    3000 m without
                                                    Fire resistance
                                                    850 °C conforming to IEC 60695-2-1
                                                    Flame retardance
                                                    V1 conforming to UL 94
                                                    Mechanical robustness
                                                  • vibrations contactor open: 2 Gn, 5...300 Hz
                                                  • vibrations contactor closed: 4 Gn, 5...300 Hz
                                                  • shocks contactor open: 10 Gn for 11 ms
                                                  • shocks contactor closed: 15 Gn for 11 ms
                                                    • Height
                                                      122 mm
                                                      Width
                                                      119 mm
                                                      Depth
                                                      120 mm
                                                      Net weight
                                                      2.174 kg
                                                      Sustainable offer status
                                                      Green Premium product
                                                      REACh Regulation
                                                      Reference contains Substances of Very High Concern above the threshold
                                                      EU RoHS Directive
                                                      Pro-active compliance (Product out of EU RoHS legal scope)
                                                      Mercury free
                                                      Yes
                                                      RoHS exemption information
                                                      Yes
                                                      China RoHS Regulation
                                                      Product out of China RoHS scope. Substance declaration for your information
                                                      Environmental Disclosure
                                                      ENVPEP1607010EN
                                                      Circularity Profile
                                                      ENVEOLI1607010EN
                                                      WEEE
                                                      The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                                                      Warranty
                                                      18 months

                                                      Documents & downloads

                                                      hide show
                                                      Filter items
                                                      • All

                                                      • CAD Files and Packs

                                                      • Product Brochures

                                                      • Movies

                                                      • Technical Data Catalogues

                                                      • Catalog Page

                                                      • Technical Leaflet

                                                      • End of Life Manual

                                                      • Handout

                                                      • Installation Instruction

                                                      • Product Environmental

                                                      • Data Bulletin

                                                      • Operating Manuals

                                                      • Application Solutions

                                                      • Declaration of Conformity

                                                      • Certificates (MSDS)

                                                      • White Paper

                                                      • eTechPub

                                                      • Marine Certificate

                                                      • Software - Released