TeSys D Reversing Contactor-3 Pole AC3 <= 440V 40A, 24V DC Coil

TeSys D Reversing Contactor-3 Pole AC3 <= 440V 40A, 24V DC Coil

TeSys D Reversing Contactor-3 Pole AC3 <= 440V 40A, 24V DC Coil

Item Number: LC2D40ABBE

Retail
$4,157.00
RRP (Inc. GST)

Product Dimensions

Width icon

Width119 mm

Height icon

Height122 mm

Depth icon

Depth120 mm

See full specifications

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

TeSys D

Range

TeSys

Product or component type

reversing contactor

Sustainable offer status

Green Premium product

Warranty

18 months

Physical

Device presentation

preassembled with reversing power busbar

[Ue] rated operational voltage

power circuit: 690 V AC 25...400 Hz

[Ie] rated operational current

  • 60 A (at <60 °C) at <= 440 V AC-1 for power circuit
  • 40 A (at <60 °C) at <= 440 V AC-3 for power circuit
    • Electrical durability

    • 2 Mcycles 35 A AC-3 at Ue <= 440 V
    • 0.7 Mcycles 60 A AC-1 at Ue <= 440 V
      • Mounting support

      • rail
      • plate
        • Standards

        • EN/IEC 60947-4-1
        • EN/IEC 60947-5-1
        • UL 60947-4-1
        • CSA C22.2 No 60947-4-1
          • Product certifications

          • CCC
          • CSA
          • EAC
          • UL
          • KC
          • DNV-GL
          • LROS (Lloyds register of shipping)
            • Connections - terminals

            • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end
            • control circuit: screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end
            • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible with cable end
            • control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end
            • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²solid
            • control circuit: screw clamp terminals 2 cable(s) 1-4 mm²solid
            • power circuit: EverLink BTR screw connectors 1 cable(s) 1-35 mm²flexible without cable end
            • power circuit: EverLink BTR screw connectors 2 cable(s) 1-25 mm²flexible without cable end
            • power circuit: EverLink BTR screw connectors 1 cable(s) 1-35 mm²flexible with cable end
            • power circuit: EverLink BTR screw connectors 2 cable(s) 1-25 mm²flexible with cable end
            • power circuit: EverLink BTR screw connectors 1 cable(s) 1-35 mm²solid
            • power circuit: EverLink BTR screw connectors 2 cable(s) 1-25 mm²solid
              • Mechanical durability

                6 Mcycles

                Insulation resistance

                > 10 MOhm for signalling circuit

                IP degree of protection

                IP20 front face conforming to IEC 60529

                Ambient air temperature for storage

                -60-80 °C

                Height

                122 mm

                Width

                119 mm

                Depth

                120 mm

                Net weight

                2.154 kg

                EU RoHS Directive

                Compliant

                Mercury free

                Yes

                RoHS exemption information

                Yes

                China RoHS Regulation

                Product out of China RoHS scope. Substance declaration for your information

                Environmental Disclosure

                ENVPEP1607010EN

                Circularity Profile

                ENVEOLI1607010EN

                Others

                Product name

                TeSys D Green

                Device short name

                LC2D

                Contactor application

              • motor control
              • resistive load
                • Utilisation category

                • AC-3
                • AC-1
                  • Poles description

                    3P

                    Pole contact composition

                    3 NO

                    Motor power kW

                  • 11 kW at 220...230 V AC 50 Hz
                  • 18.5 kW at 380...400 V AC 50 Hz
                  • 22 kW at 415 V AC 50 Hz
                  • 22 kW at 440 V AC 50 Hz
                  • 22 kW at 500 V AC 50 Hz
                  • 30 kW at 660...690 V AC 50 Hz
                    • Motor power hp

                    • 3 hp at 115 V AC 60 Hz for 1 phase motors
                    • 5 hp at 230/240 V AC 60 Hz for 1 phase motors
                    • 10 hp at 200/208 V AC 60 Hz for 3 phases motors
                    • 10 hp at 230/240 V AC 60 Hz for 3 phases motors
                    • 30 hp at 460/480 V AC 60 Hz for 3 phases motors
                    • 30 hp at 575/600 V AC 60 Hz for 3 phases motors
                      • Control circuit type

                        DC DC low consumption

                        [Uc] control circuit voltage

                        24 V DC

                        Auxiliary contact composition

                        1 NO + 1 NC

                        [Uimp] rated impulse withstand voltage

                        6 kV conforming to IEC 60947

                        Overvoltage category

                        III

                        [Ith] conventional free air thermal current

                      • 10 A (at 60 °C) for signalling circuit
                      • 60 A (at 60 °C) for power circuit
                        • Irms rated making capacity

                        • 140 A AC for signalling circuit conforming to IEC 60947-5-1
                        • 250 A DC for signalling circuit conforming to IEC 60947-5-1
                        • 800 A at 440 V for power circuit conforming to IEC 60947
                          • Rated breaking capacity

                            800 A at 440 V for power circuit conforming to IEC 60947

                            [Icw] rated short-time withstand current

                          • 100 A - 1 s for signalling circuit
                          • 120 A - 500 ms for signalling circuit
                          • 140 A - 100 ms for signalling circuit
                          • 320 A 40 °C - 10 s for power circuit
                          • 720 A 40 °C - 1 s for power circuit
                          • 72 A 40 °C - 10 min for power circuit
                          • 165 A 40 °C - 1 min for power circuit
                            • Associated fuse rating

                            • 10 A gG for signalling circuit conforming to IEC 60947-5-1
                            • 80 A gG at <= 690 V coordination type 1 for power circuit
                            • 80 A gG at <= 690 V coordination type 2 for power circuit
                              • Average impedance

                                1.5 mOhm - Ith 60 A 50 Hz for power circuit

                                [Ui] rated insulation voltage

                              • power circuit: 690 V conforming to IEC 60947-4-1
                              • signalling circuit: 690 V conforming to IEC 60947-1
                                • Power dissipation per pole

                                • 2.4 W AC-3
                                • 5.4 W AC-1
                                  • Protective cover

                                    with

                                    Interlocking type

                                    mechanical

                                    Tightening torque

                                  • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
                                  • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
                                  • power circuit: 8 N.m - on EverLink BTR screw connectors - cable 25-35 mm² hexagonal screw head 4 mm
                                  • power circuit: 5 N.m - on EverLink BTR screw connectors - cable 1-25 mm² hexagonal screw head 4 mm
                                    • Operating time

                                    • 55...65 ms closing
                                    • 20...120 ms opening (date code >= 17221)
                                    • 20...80 ms opening (date code >= 18011)
                                      • Safety reliability level

                                      • B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
                                      • B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
                                        • Maximum operating rate

                                          3600 cyc/h 60 °C

                                          Coil technology

                                          built-in bidirectional peak limiting

                                          Inrush power in W

                                          11-11 W at 20 °C

                                          Hold-in power consumption in W

                                          0.5-0.5 W at 20 °C

                                          Heat dissipation

                                          0.5-0.5 W

                                          Auxiliary contacts type

                                        • type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
                                        • type mirror contact 1 NC conforming to IEC 60947-4-1
                                          • Signalling circuit frequency

                                            25...400 Hz

                                            Minimum switching current

                                            5 mA for signalling circuit

                                            Minimum switching voltage

                                            17 V for signalling circuit

                                            Non-overlap time

                                          • 1.5 ms on de-energisation between NC and NO contact
                                          • 1.5 ms on energisation between NC and NO contact
                                            • Compatibility code

                                              LC2D

                                              Protective treatment

                                              TH conforming to IEC 60068-2-30

                                              Pollution degree

                                              3

                                              Operating altitude

                                              3000 m without derating

                                              Fire resistance

                                              850 °C conforming to IEC 60695-2-1

                                              Flame retardance

                                              V1 conforming to UL 94

                                              Mechanical robustness

                                            • vibrations contactor open: 2 Gn, 5...300 Hz
                                            • vibrations contactor closed: 4 Gn, 5...300 Hz
                                            • shocks contactor open: 10 Gn for 11 ms
                                            • shocks contactor closed: 15 Gn for 11 ms
                                              • Unit Type of Package 1

                                                PCE

                                                Number of Units in Package 1

                                                1

                                                Package 1 Weight

                                                2.35 kg

                                                Package 1 Height

                                                13.8 cm

                                                Package 1 width

                                                16.2 cm

                                                Package 1 Length

                                                19.4 cm

                                                Unit Type of Package 2

                                                S03

                                                Number of Units in Package 2

                                                4

                                                Package 2 Weight

                                                9.898 kg

                                                Package 2 Height

                                                30 cm

                                                Package 2 width

                                                30 cm

                                                Package 2 Length

                                                40 cm

                                                WEEE

                                                The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

                                                Halogen content performance

                                                Halogen free plastic parts & cables product
                                                Show all specifications

                                                Documents & downloads

                                                hide show
                                                Filter items
                                                • All

                                                • Product Brochures

                                                • CAD Files and Packs

                                                • Technical Data Catalogues

                                                • Product Environmental

                                                • End of Life Manual

                                                • Installation Instruction

                                                • Declaration of Conformity

                                                Frequently Asked Questions

                                                hide show

                                                Do the Everlink reversing contactors come with electrical interlocking?

                                                Issue:
                                                Looking for electrical interlock kit for the LC1D65A Everlnk contactors

                                                Product line:
                                                Tesys D LC1D40A, LC1D50A, LC1D65A

                                                Environment:
                                                Everlink, all voltage codes

                                                Cause:
                                                Old D2 version offered an electrical interlock kit

                                                Resolution:
                                                The current Everlink version does not offer an electrical interlock kit.  The customer can wire electrical interlocking using the normally closed contacts provided on the contactor.

                                                What are the dimensions of LC1D40AB7 ?

                                                Height 122 mm
                                                Width 55 mm
                                                Depth 120 mm
                                                Product weight 1.4 kg

                                                What is the part number for a 3 POLE, 40A, 24V AC coil contactor?

                                                The Part number for a 3 pole, 40A, 24V AC coil contactor is LC1D40AB7

                                                Are 21 volt replacement control coils available for LC2D4011?

                                                Issue:
                                                LC2D4011 replacement coil

                                                Prodcut Line:
                                                Contactors and Overload Relays

                                                Product Line:
                                                TeSys™ D Contactors and Overload Relays

                                                Resolution:
                                                21VAC coils are not an option on these reversing change over contactors.
                                                We do offer the B6 or B7 which is 24VAC.  The tolerance on the 24V coil is 85 to 110%.  So the 24VAC coil will work down to 20.4VAC. 

                                                Note the LC2D4011 series is obsolete.

                                                What replaces LC1D50BD

                                                Replacement LC1D50ABD

                                                What is the code for a 40A 110VAC contactor ?

                                                LC1D40AF7

                                                Can I use a LA9D6569 reversing kit with LC1D40AU7 contactors

                                                No, correct kit is a LAD9R3.

                                                What is the code for the newer version of the LC1D40U7

                                                That has been replaced with the Everlink LC1D40AU7

                                                What is the color scheme of the Tesys D-Line contactors?

                                                Issue:
                                                Looking for different color scheme of the Tesys D-Line contactors.

                                                Product Line:
                                                Tesys D Contactors

                                                Environment:
                                                LC1D contactors

                                                Resolution:
                                                Beige and dark gray.
                                                 

                                                Video: What auxiliary contact modules are available for the LC1D and LC2D contactors?

                                                Issue:
                                                Auxiliary contact modules for the LC1D and LC2D contactors

                                                Product Line: 
                                                Contactor and Starters - IEC

                                                Environment:
                                                North American Products

                                                Resolution:
                                                Select based on application requirements. Please note that the TeSys and Pre-TeSys auxiliary blocks are backward/forward compatible.
                                                Front Mounting; maximum of 1 block per contactor:

                                                N.O.-------N.C.-----TeSys P/N--------Pre-TeSys P/N
                                                --1-----------1---------LADN11-----------LA1DN11
                                                --1-----------1---------LADN11G---------LA1DN11G (See Footnote 1)
                                                --1-----------1---------LADN11P---------LA1DN11P (See Footnote 1)
                                                --2-----------0---------LADN20-----------LA1DN20
                                                --2-----------0---------LA1DX20---------LA1DX20 (See Footnote 2)
                                                --2-----------0---------LA1DY20---------LA1DY20 (See Footnote 3)
                                                --0-----------2---------LADN02-----------LA1DN02
                                                --2-----------2---------LADN22-----------LA1DN22
                                                --2-----------2---------LADN22G---------LA1DN22G (See Footnote 1)
                                                --2-----------2---------LADN22P---------LA1DN22P (See Footnote 1)
                                                --2-----------2---------LADC22------------LA1DC22 (See Footnote 4)
                                                --3-----------1---------LADN31------------LA1DN31
                                                --3-----------1---------LA1DZ31----------LA1DZ31 (See Footnote 5)
                                                --1-----------3---------LADN13------------LA1DN13
                                                --4-----------0---------LADN40------------LA1DN40
                                                --4-----------0---------LA1DZ40-----------LA1DZ40 (See Footnote 6)
                                                --0-----------4---------LADN04------------LA1DN04




                                                Front Mounting; maximum of 1 block per contactor: For use with D2 Series 25 amp through 80 amp contactors and TeSys Series 40 amp through 80 amp only.

                                                N.O.-------N.C.-----TeSys P/N--------Pre-TeSys P/N
                                                --1-----------0--------LADN10----------LA1DN10
                                                --0-----------1--------LADN01----------LA1DN01

                                                Side Mounting; maximum of 1 block on each side for D2 Series and Tesys Series 40 through 80 amp contactors. Tesys 9 through 32, 115, and 150 amps contactors will accept 1 block and is limited to left side only. (*) DC control devices will not accept side mount auxiliaries.
                                                (*) DC control exceptions that will accept one left side mounted auxiliary: LC1D115 & LC1D150.

                                                N.O.-------N.C.-----TeSys P/N--------Pre-TeSys P/N
                                                --1-----------1--------LAD8N11----------LA8DN11
                                                --2-----------0--------LAD8N20----------LA8DN20
                                                --0-----------2--------LAD8N02----------N/A

                                                Footnotes:
                                                {1} EN50 012 Machine Tool Terminal Markings
                                                {2} (2) NO Sealed Dust Tight Contacts
                                                {3} Gold Flash Contacts
                                                {4} (1) NO & (1) NC Standard and (1) NO & (1) NC Make Before Break
                                                {5} (2) NO Dust Tight Contacts & (1) NO & (1) NC Standard Contacts
                                                {6} (2) NO Dust Tight Contacts & (2) NO Standard Contacts

                                                Are contactors LC1D38.. and LC1D40A.. the same size?

                                                No the two contactor are not the same size, LC1D40A.. is bigger.

                                                LC1D38N7
                                                TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 38 A - 415 V AC 50/60 Hz coil     LC1D40AN7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 40 A - 415 V AC 50/60 Hz coil

                                                For more information see:
                                                https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=LC1D38N7;
                                                https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=LC1D40AN7




                                                 

                                                Are the D-Line contactors rated to break DC voltages?

                                                Issue: 
                                                Can the TeSys D line be used to control DC loads? 

                                                Product Line:
                                                Tesys D contactors

                                                Environment:
                                                Products sold and used in the United States
                                                 
                                                Cause:
                                                 DC power circuit
                                                 
                                                Resolution:
                                                 
                                                Yes, 75 VDC (125 VDC for D115 & D150) per pole which means that through a four pole device breaking 300 VDC is possible by wiring all four power poles in series. However, be aware that the device current ratings will differ according to the number of poles in series and the type of application.

                                                Devices are suitable but not UL Listed for DC applications.

                                                More information on their DC ratings can be found in the current TeSys Motor Control and Protection Compentns catalog: https://www.schneider-electric.us/en/download/document/MKTED210011EN/


                                                 
                                                Show More