TeSys D reversing contactor-3P-AC3 440V 12A 100-250V  ACDC coil

TeSys D Reversing Contactor-3 Pole AC3 <= 440V 12A, 100 - 250V ACDC Coil

Catalogue Number: LC2D12KUE
TeSys D reversing contactor-3P-AC3 440V 12A 100-250V  ACDC coil
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Range of product
TeSys D
Range
TeSys
Product name
TeSys D Green
Product or component type
reversing contactor
Device short name
LC2D
Contactor application
  • resistive load
  • motor control
    • Utilisation category
    • AC-1
    • AC-3
      • Device presentation
        preassembled with reversing power busbar
        Poles description
        3P
        Pole contact composition
        3 NO
        [Ue] rated operational voltage
        power circuit: <= 690 V AC 25...400 Hz
        [Ie] rated operational current
      • 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
      • 12 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
        • Motor power kW
        • 3 kW at 220...230 V AC 50 Hz
        • 5.5 kW at 380...400 V AC 50 Hz
        • 5.5 kW at 415 V AC 50 Hz
        • 5.5 kW at 440 V AC 50 Hz
        • 7.5 kW at 500 V AC 50 Hz
        • 7.5 kW at 660...690 V AC 50 Hz
          • Motor power hp
          • 0.5 hp at 115 V AC 60 Hz for 1 phase motors
          • 2 hp at 230/240 V AC 60 Hz for 1 phase motors
          • 3 hp at 200/208 V AC 60 Hz for 3 phases motors
          • 3 hp at 230/240 V AC 60 Hz for 3 phases motors
          • 7.5 hp at 460/480 V AC 60 Hz for 3 phases motors
          • 10 hp at 575/600 V AC 60 Hz for 3 phases motors
            • Control circuit type
            • AC at 50/60 Hz AC/DC electronic
            • DC AC/DC electronic
              • [Uc] control circuit voltage
              • 100...250 V AC 50/60 Hz
              • 100...250 V DC
                • Auxiliary contact composition
                  1 NO + 1 NC
                  [Uimp] rated impulse withstand voltage
                  6 kV conforming to IEC 60947
                  Overvoltage category
                  III
                  [Ith] conventional free air thermal current
                • 10 A (at 60 °C) for signalling circuit
                • 25 A (at 60 °C) for power circuit
                  • Irms rated making capacity
                  • 250 A at 440 V for power circuit conforming to IEC 60947
                  • 140 A AC for signalling circuit conforming to IEC 60947-5-1
                  • 250 A DC for signalling circuit conforming to IEC 60947-5-1
                    • Rated breaking capacity
                      250 A at 440 V for power circuit conforming to IEC 60947
                      [Icw] rated short-time withstand current
                    • 105 A 40 °C - 10 s for power circuit
                    • 210 A 40 °C - 1 s for power circuit
                    • 30 A 40 °C - 10 min for power circuit
                    • 61 A 40 °C - 1 min for power circuit
                    • 100 A - 1 s for signalling circuit
                    • 120 A - 500 ms for signalling circuit
                    • 140 A - 100 ms for signalling circuit
                      • Associated fuse rating
                      • 10 A gG for signalling circuit conforming to IEC 60947-5-1
                      • 40 A gG at <= 690 V coordination type 1 for power circuit
                      • 25 A gG at <= 690 V coordination type 2 for power circuit
                        • Average impedance
                          2.5 mOhm - Ith 25 A 50 Hz for power circuit
                          [Ui] rated insulation voltage
                        • power circuit: 690 V conforming to IEC 60947-4-1
                        • signalling circuit: 690 V conforming to IEC 60947-1
                          • Electrical durability
                          • 2.3 Mcycles 11 A AC-3 at Ue <= 440 V
                          • 0.8 Mcycles 25 A AC-1 at Ue <= 440 V
                            • Power dissipation per pole
                            • 1.56 W AC-1
                            • 0.36 W AC-3
                              • Protective cover
                                with
                                Interlocking type
                                mechanical
                                Mounting support
                              • rail
                              • plate
                                • Standards
                                • EN/IEC 60947-4-1
                                • EN/IEC 60947-5-1
                                • UL 60947-4-1
                                • CSA C22.2 No 60947-4-1
                                  • Product certifications
                                  • CCC
                                  • CSA
                                  • EAC
                                  • UL
                                  • KC
                                  • DNV-GL
                                  • LROS (Lloyds register of shipping)
                                    • Connections - terminals
                                    • power circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end
                                    • power circuit: screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end
                                    • power circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible with cable end
                                    • power circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end
                                    • power circuit: screw clamp terminals 1 cable(s) 1-4 mm²solid
                                    • power circuit: screw clamp terminals 2 cable(s) 1-4 mm²solid
                                    • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end
                                    • control circuit: screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end
                                    • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible with cable end
                                    • control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end
                                    • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²solid
                                    • control circuit: screw clamp terminals 2 cable(s) 1-4 mm²solid
                                      • Tightening torque
                                      • power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
                                      • power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
                                      • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
                                      • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
                                        • Operating time
                                        • 45...55 ms closing
                                        • 20...90 ms opening
                                          • Safety reliability level
                                          • B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
                                          • B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
                                            • Mechanical durability
                                              15 Mcycles
                                              Maximum operating rate
                                              3600 cyc/h 60 °C
                                              Coil technology
                                              built-in bidirectional peak limiting
                                              Control circuit voltage limits
                                            • drop-out: <= 0.1 Uc (at 60 °C)
                                            • operational: 0.85...1.1 Uc (at 60 °C)
                                              • Inrush power in VA
                                                25-25 VA 50/60 Hz (at 20 °C)
                                                Inrush power in W
                                                18-18 W at 20 °C
                                                Hold-in power consumption in VA
                                                1.6-1.6 VA (at 20 °C) 50/60 Hz
                                                Hold-in power consumption in W
                                                1.1-1.1 W at 20 °C
                                                Heat dissipation
                                                1.1-1.1 W at 50/60 Hz
                                                Auxiliary contacts type
                                              • type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
                                              • type mirror contact 1 NC conforming to IEC 60947-4-1
                                                • Signalling circuit frequency
                                                  25...400 Hz
                                                  Minimum switching current
                                                  5 mA for signalling circuit
                                                  Minimum switching voltage
                                                  17 V for signalling circuit
                                                  Non-overlap time
                                                • 1.5 ms on de-energisation between NC and NO contact
                                                • 1.5 ms on energisation between NC and NO contact
                                                  • Insulation resistance
                                                    > 10 MOhm for signalling circuit
                                                    Compatibility code
                                                    LC2D
                                                    IP degree of protection
                                                    IP20 front face conforming to IEC 60529
                                                    Protective treatment
                                                    TH conforming to IEC 60068-2-30
                                                    Pollution degree
                                                    3
                                                    Ambient air temperature for operation
                                                    -25-60 °C
                                                    Ambient air temperature for storage
                                                    -60-80 °C
                                                    Permissible ambient air temperature around the device
                                                    -40-70 °C at Uc
                                                    Operating altitude
                                                    3000 m without
                                                    Fire resistance
                                                    850 °C conforming to IEC 60695-2-1
                                                    Flame retardance
                                                    V1 conforming to UL 94
                                                    Mechanical robustness
                                                  • vibrations contactor open: 2 Gn, 5...300 Hz
                                                  • vibrations contactor closed: 4 Gn, 5...300 Hz
                                                  • shocks contactor open: 10 Gn for 11 ms
                                                  • shocks contactor closed: 15 Gn for 11 ms
                                                    • Height
                                                      77 mm
                                                      Width
                                                      90 mm
                                                      Depth
                                                      86 mm
                                                      Net weight
                                                      0.793 kg
                                                      Sustainable offer status
                                                      Green Premium product
                                                      EU RoHS Directive
                                                      Compliant
                                                      Mercury free
                                                      Yes
                                                      RoHS exemption information
                                                      Yes
                                                      China RoHS Regulation
                                                      Product out of China RoHS scope. Substance declaration for your information
                                                      Environmental Disclosure
                                                      ENVPEP1609001EN
                                                      Circularity Profile
                                                      ENVEOLI1609001EN
                                                      WEEE
                                                      The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                                                      Halogen content performance
                                                      Halogen free plastic parts & cables product
                                                      Warranty
                                                      18 months

                                                      Documents & downloads

                                                      hide show
                                                      Filter items
                                                      • All

                                                      • Product Brochures

                                                      • CAD Files and Packs

                                                      • Technical Data Catalogues

                                                      • Product Environmental

                                                      • End of Life Manual

                                                      • Installation Instruction

                                                      • Declaration of Conformity

                                                      Frequently Asked Questions

                                                      hide show

                                                      Where are the control coil terminals for TeSys LC1D09 to LC1D38 contactor?

                                                      Issue:
                                                      Determine the control coil terminal marking and location on LC1D09 to LC1D38 contactor

                                                      Product Line: 
                                                      Tesys D Contactors

                                                      Environment:
                                                      IEC contactors

                                                      Resolution:
                                                      The coil terminals are marked A1 and A2, you can see them on the front of the contactor on the white part (control section).  They are next to the auxiliary contact (13/14, 21/22) terminals.
                                                       

                                                      Are 600 volt replacement control coils available for LC2D1211?

                                                      Issue:
                                                      Looking for an LC2D1211 replacement control coils.

                                                      Product Line:
                                                      Tesys D Contactors

                                                      Environment:
                                                      LC2D1211

                                                      Resolution:
                                                      This coil is obsolete. Replace the contactor with the new TeSys product, LC2D12X7. Note this is a functional equal only. Accessories for the old product may or may not fit the new design. Confirm dimensions.
                                                       

                                                      What is the maximum UL/CSA AC voltage rating of the LC1D power contacts ?

                                                      Issue:
                                                      Identifying maximum voltage of an LC1D contactor

                                                      Product Line:
                                                      TeSys D Contactors

                                                      Environment:
                                                      IEC contactors and starters used in North America

                                                      Cause:
                                                      n/a

                                                      Resolution:
                                                      IThe maximum voltage per UL and CSA is 600VAC. 
                                                       

                                                      Need a LC2D323U7 reversing contactor

                                                      Use 2 x LC1D32U7 with a LAD9R1V reversing wiring kit

                                                      What is the replacement coil part number for the LC*D09 through LC*D32 and LC*DT20 through LC*DT40 TeSys contactors?

                                                      Issue:
                                                      Identifying replacement coils for tesys D non-reversing and reversing conactors

                                                      Product Line:
                                                      IEC Contactors and Starters

                                                      Environment:
                                                      Products sold and used in the United States

                                                      Cause:
                                                      Replacement coil is needed

                                                      Resolution:
                                                      DC replacement coils are not available.
                                                      AC Coils are 50/60 hertz for voltages as listed below:

                                                      Volts - Part Number
                                                      12 ____ LXD1J7
                                                      21 ____ LXD1Z7
                                                      24 ____ LXD1B7
                                                      32 ____ LXD1C7
                                                      36 ____ LXD1CC7
                                                      42 ____ LXD1D7
                                                      48 ____ LXD1E7
                                                      60 ____ LXD1EE7
                                                      100 ___ LXD1K7 ( never brought to North America )
                                                      110 ___ LXD1F7
                                                      115 ___ LXD1FE7
                                                      120 ___ LXD1G7
                                                      127 ___ LXD1FC7
                                                      200 ___ LXD1L7
                                                      208 ___ LXD1LE7
                                                      220 ___ LXD1M7
                                                      230 ___ LXD1P7
                                                      240 ___ LXD1U7
                                                      277 ___ LXD1W7
                                                      380 ___ LXD1Q7
                                                      400 ___ LXD1V7
                                                      415 ___ LXD1N7
                                                      440 ___ LXD1R7
                                                      480 ___ LXD1T7
                                                      575 ___ LXD1SC7
                                                      600 ___ LXD1X7
                                                      690 ___ LXD1Y7


                                                      Note: A contactor with an AC coil can be changed to a different AC voltage coil, IE you can take an LC1D09 with a 120VAC coil and put a 24VAC coil in it instead. An AC device cannot be switched to a DC coil, and a DC device cannot be switches to an AC coil. 

                                                      Will the LC1D12U7 contactor go with the LADR2 timer?

                                                      Yes it will. the LADR2 timer slides on the top of the LC1D12U7 contactor.

                                                      What is the mechanical durability of a LC1D12U7 contactor

                                                       It is 15 Million cycles

                                                      Are 48 volt AC replacement control coils available for LC2D1801?

                                                      Issue:
                                                      Checking if a 48 volt AC replacement coil is available for an LC2D1801.

                                                      Product Line:
                                                      Tesys D Contactors

                                                      Environment:
                                                      LC1D1810

                                                      Resolution:
                                                      This coil is obsolete. Replace the contactor with the new TeSys product, LC2D18E7. Note this is a functional equal only. Accessories for the old product may or may not fit the new design. Confirm dimensions.
                                                       

                                                      Can the LE1D and LE2D enclosed Tesys D-Line contactors be obtained with DC control coils?

                                                      Issue:  
                                                      Tesys D enclosed starter with a DC control 

                                                      Product Line:
                                                       Enclosed Tesys D line starters

                                                      Environment:
                                                      North American Products
                                                       
                                                      Cause:
                                                      DC control circuit 
                                                       
                                                      Resolution:
                                                      Yes but limited to 24 VDC.

                                                      What is the rating of auxiliaries on standard LC1D12U7 contactor

                                                       Rated at 10A thermal.

                                                      What is the power terminal lug data for the LC1D09, LC1DT20, LC1D12, and LC1DT25 contactor?

                                                      Issue:
                                                      Power terminal lug data required for the 9 and 12 amp rated Tesys D contactors

                                                      Product Line:
                                                      NEMA combination starters

                                                      Environment:
                                                      Products sold and used in the United States

                                                      Resolution:
                                                      For contactors with screw clamp terminals:
                                                      stranded cable w/o cable end : One or Two #18-10 AWG per terminal.
                                                      stranded cable w/cable end: One or Two #18-10 AWG per terminal.
                                                      solid cable: One or Two #18-8 AWG per terminal.

                                                      What is the coil consumption or burden for the Tesys LC*D** contactors?

                                                      * 1 or 2
                                                      ** 09 through 38

                                                      Issue:
                                                      Coil consumption or burden for the Tesys LC1D/2D contactors from 9A - 38A

                                                      Product Line: 
                                                      Contactors and Starters - IEC

                                                      Environment:
                                                      North American Products

                                                      Resolution:
                                                      All AC coils for the LC1D09 through LC1D38 3-pole contactors ( including ring tongue, quick connect and spring terminal versions ) have an inrush of 70 volt-amps for either 50 or 60 Hertz applications, and a sealed value of 7 volt-amps for 50Hertz applications or 7.5 volt-amps for 60 Hertz applications.