TeSys D Reversing Contactor-3 Pole AC3 <= 440V 12A, 48 - 130V ACDC Coil

TeSys D Reversing Contactor-3 Pole AC3 <= 440V 12A, 48 - 130V ACDC Coil

TeSys D Reversing Contactor-3 Pole AC3 <= 440V 12A, 48 - 130V ACDC Coil

Item Number: LC2D12EHE

Retail
$1,087.28
RRP (Inc. GST)

Product Dimensions

Width icon

Width90 mm

Height icon

Height77 mm

Depth icon

Depth86 mm

See full specifications

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

TeSys D

Range

TeSys

Product or component type

reversing contactor

Sustainable offer status

Green Premium product

Warranty

18 months

Physical

Device presentation

preassembled with reversing power busbar

[Ue] rated operational voltage

power circuit: <= 690 V AC 25...400 Hz

[Ie] rated operational current

  • 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
  • 12 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
    • Electrical durability

    • 2.3 Mcycles 11 A AC-3 at Ue <= 440 V
    • 0.8 Mcycles 25 A AC-1 at Ue <= 440 V
      • Mounting support

      • plate
      • rail
        • Standards

        • EN/IEC 60947-4-1
        • EN/IEC 60947-5-1
        • UL 60947-4-1
        • CSA C22.2 No 60947-4-1
          • Product certifications

          • CCC
          • CSA
          • EAC
          • UL
          • KC
          • DNV-GL
          • LROS (Lloyds register of shipping)
            • Connections - terminals

            • power circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end
            • power circuit: screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end
            • power circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible with cable end
            • power circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end
            • power circuit: screw clamp terminals 1 cable(s) 1-4 mm²solid
            • power circuit: screw clamp terminals 2 cable(s) 1-4 mm²solid
            • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end
            • control circuit: screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end
            • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible with cable end
            • control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end
            • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²solid
            • control circuit: screw clamp terminals 2 cable(s) 1-4 mm²solid
              • Mechanical durability

                15 Mcycles

                Insulation resistance

                > 10 MOhm for signalling circuit

                IP degree of protection

                IP20 front face conforming to IEC 60529

                Ambient air temperature for storage

                -60-80 °C

                Height

                77 mm

                Width

                90 mm

                Depth

                86 mm

                Net weight

                0.793 kg

                EU RoHS Directive

                Compliant

                Mercury free

                Yes

                RoHS exemption information

                Yes

                China RoHS Regulation

                Product out of China RoHS scope. Substance declaration for your information

                Environmental Disclosure

                ENVPEP1609001EN

                Circularity Profile

                ENVEOLI1609001EN

                Others

                Product name

                TeSys D Green

                Device short name

                LC2D

                Contactor application

              • resistive load
              • motor control
                • Utilisation category

                • AC-3
                • AC-1
                  • Poles description

                    3P

                    Pole contact composition

                    3 NO

                    Motor power kW

                  • 3 kW at 220...230 V AC 50 Hz
                  • 5.5 kW at 380...400 V AC 50 Hz
                  • 5.5 kW at 415 V AC 50 Hz
                  • 5.5 kW at 440 V AC 50 Hz
                  • 7.5 kW at 500 V AC 50 Hz
                  • 7.5 kW at 660...690 V AC 50 Hz
                    • Motor power hp

                    • 0.5 hp at 115 V AC 60 Hz for 1 phase motors
                    • 2 hp at 230/240 V AC 60 Hz for 1 phase motors
                    • 3 hp at 200/208 V AC 60 Hz for 3 phases motors
                    • 3 hp at 230/240 V AC 60 Hz for 3 phases motors
                    • 7.5 hp at 460/480 V AC 60 Hz for 3 phases motors
                    • 10 hp at 575/600 V AC 60 Hz for 3 phases motors
                      • Control circuit type

                      • AC at 50/60 Hz AC/DC electronic
                      • DC AC/DC electronic
                        • [Uc] control circuit voltage

                        • 48...130 V AC 50/60 Hz
                        • 48...130 V DC
                          • Auxiliary contact composition

                            1 NO + 1 NC

                            [Uimp] rated impulse withstand voltage

                            6 kV conforming to IEC 60947

                            Overvoltage category

                            III

                            [Ith] conventional free air thermal current

                          • 10 A (at 60 °C) for signalling circuit
                          • 25 A (at 60 °C) for power circuit
                            • Irms rated making capacity

                            • 250 A at 440 V for power circuit conforming to IEC 60947
                            • 140 A AC for signalling circuit conforming to IEC 60947-5-1
                            • 250 A DC for signalling circuit conforming to IEC 60947-5-1
                              • Rated breaking capacity

                                250 A at 440 V for power circuit conforming to IEC 60947

                                [Icw] rated short-time withstand current

                              • 105 A 40 °C - 10 s for power circuit
                              • 210 A 40 °C - 1 s for power circuit
                              • 30 A 40 °C - 10 min for power circuit
                              • 61 A 40 °C - 1 min for power circuit
                              • 100 A - 1 s for signalling circuit
                              • 120 A - 500 ms for signalling circuit
                              • 140 A - 100 ms for signalling circuit
                                • Associated fuse rating

                                • 10 A gG for signalling circuit conforming to IEC 60947-5-1
                                • 40 A gG at <= 690 V coordination type 1 for power circuit
                                • 25 A gG at <= 690 V coordination type 2 for power circuit
                                  • Average impedance

                                    2.5 mOhm - Ith 25 A 50 Hz for power circuit

                                    [Ui] rated insulation voltage

                                  • power circuit: 690 V conforming to IEC 60947-4-1
                                  • signalling circuit: 690 V conforming to IEC 60947-1
                                    • Power dissipation per pole

                                    • 1.56 W AC-1
                                    • 0.36 W AC-3
                                      • Protective cover

                                        with

                                        Interlocking type

                                        mechanical

                                        Tightening torque

                                      • power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
                                      • power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
                                      • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
                                      • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
                                        • Operating time

                                        • 45...55 ms closing
                                        • 20...90 ms opening
                                          • Safety reliability level

                                          • B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
                                          • B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
                                            • Maximum operating rate

                                              3600 cyc/h 60 °C

                                              Coil technology

                                              built-in bidirectional peak limiting

                                              Inrush power in VA

                                              25-25 VA 50/60 Hz (at 20 °C)

                                              Inrush power in W

                                              24-24 W at 20 °C

                                              Hold-in power consumption in VA

                                              1.3-1.3 VA (at 20 °C) 50/60 Hz

                                              Hold-in power consumption in W

                                              0.8-0.8 W at 20 °C

                                              Heat dissipation

                                              0.8-0.8 W at 50/60 Hz

                                              Auxiliary contacts type

                                            • type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
                                            • type mirror contact 1 NC conforming to IEC 60947-4-1
                                              • Signalling circuit frequency

                                                25...400 Hz

                                                Minimum switching current

                                                5 mA for signalling circuit

                                                Minimum switching voltage

                                                17 V for signalling circuit

                                                Non-overlap time

                                              • 1.5 ms on de-energisation between NC and NO contact
                                              • 1.5 ms on energisation between NC and NO contact
                                                • Compatibility code

                                                  LC2D

                                                  Protective treatment

                                                  TH conforming to IEC 60068-2-30

                                                  Pollution degree

                                                  3

                                                  Operating altitude

                                                  3000 m without derating

                                                  Fire resistance

                                                  850 °C conforming to IEC 60695-2-1

                                                  Flame retardance

                                                  V1 conforming to UL 94

                                                  Mechanical robustness

                                                • vibrations contactor open: 2 Gn, 5...300 Hz
                                                • vibrations contactor closed: 4 Gn, 5...300 Hz
                                                • shocks contactor open: 10 Gn for 11 ms
                                                • shocks contactor closed: 15 Gn for 11 ms
                                                  • Package 1 Weight

                                                    0.793 kg

                                                    Package 1 Height

                                                    0.92 dm

                                                    Package 1 width

                                                    1.35 dm

                                                    Package 1 Length

                                                    1.12 dm

                                                    WEEE

                                                    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

                                                    Halogen content performance

                                                    Halogen free plastic parts & cables product
                                                    Show all specifications

                                                    Documents & downloads

                                                    hide show
                                                    Filter items
                                                    • All

                                                    • Product Brochures

                                                    • CAD Files and Packs

                                                    • Technical Data Catalogues

                                                    • Product Environmental

                                                    • End of Life Manual

                                                    • Installation Instruction

                                                    • Declaration of Conformity

                                                    Frequently Asked Questions

                                                    hide show

                                                    Where are the control coil terminals for TeSys LC1D09 to LC1D38 contactor?

                                                    Issue:
                                                    Determine the control coil terminal marking and location on LC1D09 to LC1D38 contactor

                                                    Product Line: 
                                                    Tesys D Contactors

                                                    Environment:
                                                    IEC contactors

                                                    Resolution:
                                                    The coil terminals are marked A1 and A2, you can see them on the front of the contactor on the white part (control section).  They are next to the auxiliary contact (13/14, 21/22) terminals.
                                                     

                                                    Are 600 volt replacement control coils available for LC2D1211?

                                                    Issue:
                                                    Looking for an LC2D1211 replacement control coils.

                                                    Product Line:
                                                    Tesys D Contactors

                                                    Environment:
                                                    LC2D1211

                                                    Resolution:
                                                    This coil is obsolete. Replace the contactor with the new TeSys product, LC2D12X7. Note this is a functional equal only. Accessories for the old product may or may not fit the new design. Confirm dimensions.
                                                     

                                                    Are 48 volt AC replacement control coils available for LC2D1801?

                                                    Issue:
                                                    Checking if a 48 volt AC replacement coil is available for an LC2D1801.

                                                    Product Line:
                                                    Tesys D Contactors

                                                    Environment:
                                                    LC1D1810

                                                    Resolution:
                                                    This coil is obsolete. Replace the contactor with the new TeSys product, LC2D18E7. Note this is a functional equal only. Accessories for the old product may or may not fit the new design. Confirm dimensions.
                                                     

                                                    What is the replacement coil part number for the LC*D09 through LC*D32 and LC*DT20 through LC*DT40 TeSys contactors?

                                                    Issue:
                                                    Identifying replacement coils for tesys D non-reversing and reversing conactors

                                                    Product Line:
                                                    IEC Contactors and Starters

                                                    Environment:
                                                    Products sold and used in the United States

                                                    Cause:
                                                    Replacement coil is needed

                                                    Resolution:
                                                    DC replacement coils are not available.
                                                    AC Coils are 50/60 hertz for voltages as listed below:

                                                    Volts - Part Number
                                                    12 ____ LXD1J7
                                                    21 ____ LXD1Z7
                                                    24 ____ LXD1B7
                                                    32 ____ LXD1C7
                                                    36 ____ LXD1CC7
                                                    42 ____ LXD1D7
                                                    48 ____ LXD1E7
                                                    60 ____ LXD1EE7
                                                    100 ___ LXD1K7 ( never brought to North America )
                                                    110 ___ LXD1F7
                                                    115 ___ LXD1FE7
                                                    120 ___ LXD1G7
                                                    127 ___ LXD1FC7
                                                    200 ___ LXD1L7
                                                    208 ___ LXD1LE7
                                                    220 ___ LXD1M7
                                                    230 ___ LXD1P7
                                                    240 ___ LXD1U7
                                                    277 ___ LXD1W7
                                                    380 ___ LXD1Q7
                                                    400 ___ LXD1V7
                                                    415 ___ LXD1N7
                                                    440 ___ LXD1R7
                                                    480 ___ LXD1T7
                                                    575 ___ LXD1SC7
                                                    600 ___ LXD1X7
                                                    690 ___ LXD1Y7


                                                    Note: A contactor with an AC coil can be changed to a different AC voltage coil, IE you can take an LC1D09 with a 120VAC coil and put a 24VAC coil in it instead. An AC device cannot be switched to a DC coil, and a DC device cannot be switches to an AC coil. 

                                                    Can the LE1D and LE2D enclosed Tesys D-Line contactors be obtained with DC control coils?

                                                    Issue:  
                                                    Tesys D enclosed starter with a DC control 

                                                    Product Line:
                                                     Enclosed Tesys D line starters

                                                    Environment:
                                                    North American Products
                                                     
                                                    Cause:
                                                    DC control circuit 
                                                     
                                                    Resolution:
                                                    Yes but limited to 24 VDC.

                                                    What is the altitude derating for a TeSys D-Line contactor?

                                                    Issue:​
                                                    What is the altitude derating for a TeSys D-Line contactor?

                                                    Product Line:
                                                    Digest 177 Section 18 : Contactors and Starters, IEC

                                                    Environment:
                                                    North American Products

                                                    Resolution:
                                                    The contactors are fully rated up to 3000 meters. Following are derating multipliers for altitudes above 3000 meters for both voltage and current:

                                                    Voltage
                                                    3500m x 0.90
                                                    4000m x 0.80
                                                    4500m x 0.70
                                                    5000m x 0.60

                                                    Current
                                                    3500m x 0.92
                                                    4000m x 0.90
                                                    4500m x 0.88
                                                    5000m x 0.86

                                                    For example, an LC1D80 at 5000 meters:
                                                    - The maximum rated operational voltage is 1,000V (IEC947-4) and 690V (UL/CSA). At 5000 meters it becomes 1000V x 0.6 = 600V (IEC947-4) and 690V x 0.6 = 414V (UL/CSA).
                                                    - The maximum rated operational AC3 current is 80A. At 5000 meters it becomes 80A x 0.86 = 68A.



                                                     

                                                    What is the coil consumption or burden for the Tesys LC*D** contactors?

                                                    * 1 or 2
                                                    ** 09 through 38

                                                    Issue:
                                                    Coil consumption or burden for the Tesys LC1D/2D contactors from 9A - 38A

                                                    Product Line: 
                                                    Contactors and Starters - IEC

                                                    Environment:
                                                    North American Products

                                                    Resolution:
                                                    All AC coils for the LC1D09 through LC1D38 3-pole contactors ( including ring tongue, quick connect and spring terminal versions ) have an inrush of 70 volt-amps for either 50 or 60 Hertz applications, and a sealed value of 7 volt-amps for 50Hertz applications or 7.5 volt-amps for 60 Hertz applications.

                                                    What is the maximum UL/CSA AC voltage rating of the LC1D power contacts ?

                                                    Issue:
                                                    Identifying maximum voltage of an LC1D contactor

                                                    Product Line:
                                                    TeSys D Contactors

                                                    Environment:
                                                    IEC contactors and starters used in North America

                                                    Cause:
                                                    n/a

                                                    Resolution:
                                                    IThe maximum voltage per UL and CSA is 600VAC. 
                                                     

                                                    Can a GV2AF3 or GV2AF4 interconnection block work on a contactor with a DC coil?

                                                    Issue:
                                                    Mounting adaptor for GV2 and LC1D contactor

                                                    Product Line:
                                                    Motor Starters and Protectors

                                                    Environment:
                                                    TeSys GV Manual Starter and Protectors
                                                    Tesys D Contactors
                                                     
                                                    Resolution:
                                                    The GV2AF3 clip has to be moved to the DC position to accommodate the contactor with a DC coil.

                                                    Need a LC2D323U7 reversing contactor

                                                    Use 2 x LC1D32U7 with a LAD9R1V reversing wiring kit

                                                    What is the power terminal lug data for the LC1D09, LC1DT20, LC1D12, and LC1DT25 contactor?

                                                    Issue:
                                                    Power terminal lug data required for the 9 and 12 amp rated Tesys D contactors

                                                    Product Line:
                                                    NEMA combination starters

                                                    Environment:
                                                    Products sold and used in the United States

                                                    Resolution:
                                                    For contactors with screw clamp terminals:
                                                    stranded cable w/o cable end : One or Two #18-10 AWG per terminal.
                                                    stranded cable w/cable end: One or Two #18-10 AWG per terminal.
                                                    solid cable: One or Two #18-8 AWG per terminal.

                                                    What is the part number for the spacer used with the LC*D09 through LC*D32 Contactor and the GV2AF3 combination block when the GV2 Motor Circuit Protector is mounted on din rail and the contactor hangs below it?

                                                    Issue:
                                                    Identifying the spacer part number for use with a LC*D, GV2AF3, and GV2 device combination

                                                    Product Line:
                                                    Contactors and Starters IEC

                                                    Environment:
                                                    Tesys D contactors and GV manual starters

                                                    Cause:
                                                    Spacer required

                                                    Resolution:
                                                    Compensation plate catalog number GV1F03, requires 2 pieces snap together.
                                                    Show More