Quantcast

TeSys D Contactor, 4P(4 NO), AC-1, <= 440V, 25A, 24VDC, Standard Coil

TeSys D Contactor, 4P(4 NO), AC-1, <= 440V, 25A, 24VDC, Standard Coil

TeSys D Contactor, 4P(4 NO), AC-1, <= 440V, 25A, 24VDC, Standard Coil

Item Number: LC1DT25BD

Retail
$890.57
RRP (Inc. GST)

Product Dimensions

Width icon

Width45 mm

Height icon

Height85 mm

Depth icon

Depth99 mm

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

TeSys D

Range

TeSys

Product or component type

contactor

Sustainable offer status

Green Premium product

Warranty

18 months

Physical

[Ue] rated operational voltage

  • power circuit: <= 690 V AC 25...400 Hz
  • power circuit: <= 300 V DC
    • [Ie] rated operational current

      25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit

      Electrical durability

      0.8 Mcycles 25 A AC-1 at Ue <= 440 V

      Mounting support

    • rail
    • plate
      • Standards

      • CSA C22.2 No 14
      • EN 60947-4-1
      • EN 60947-5-1
      • IEC 60947-4-1
      • IEC 60947-5-1
      • UL 508
        • Product certifications

        • CCC
        • GL
        • BV
        • LROS (Lloyds register of shipping)
        • CSA
        • DNV
        • RINA
        • UL
        • GOST
          • Connections - terminals

          • control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end
          • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end
          • control circuit: screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end
          • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible with cable end
          • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²solid without cable end
          • control circuit: screw clamp terminals 2 cable(s) 1-4 mm²solid without cable end
          • power circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end
          • power circuit: screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end
          • power circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible with cable end
          • power circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end
          • power circuit: screw clamp terminals 1 cable(s) 1-4 mm²solid without cable end
          • power circuit: screw clamp terminals 2 cable(s) 1-4 mm²solid without cable end
            • Mechanical durability

              30 Mcycles

              Insulation resistance

              > 10 MOhm for signalling circuit

              IP degree of protection

              IP20 front face conforming to IEC 60529

              Ambient air temperature for operation

            • -40-60 °C
            • 60-70 °C with derating
              • Ambient air temperature for storage

                -60-80 °C

                Height

                85 mm

                Width

                45 mm

                Depth

                99 mm

                Net weight

                0.365 kg

                REACh Regulation

                Free of Substances of Very High Concern above the threshold

                EU RoHS Directive

                Compliant

                Mercury free

                Yes

                RoHS exemption information

                Yes

                China RoHS Regulation

                Product out of China RoHS scope. Substance declaration for your information

                Environmental Disclosure

                ENVPEP110230EN

                Circularity Profile

                ENVEOLI1102030EN

                California proposition 65

                WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov

                Others

                Product name

                TeSys D

                Device short name

                LC1D

                Contactor application

                resistive load

                Utilisation category

                AC-1

                Poles description

                4P

                Pole contact composition

                4 NO

                Control circuit type

                DC standard

                [Uc] control circuit voltage

                24 V DC

                Auxiliary contact composition

                1 NO + 1 NC

                [Uimp] rated impulse withstand voltage

                6 kV conforming to IEC 60947

                Overvoltage category

                III

                [Ith] conventional free air thermal current

              • 10 A (at 60 °C) for signalling circuit
              • 25 A (at 60 °C) for power circuit
                • Irms rated making capacity

                • 140 A AC for signalling circuit conforming to IEC 60947-5-1
                • 250 A DC for signalling circuit conforming to IEC 60947-5-1
                • 250 A at 440 V for power circuit conforming to IEC 60947
                  • Rated breaking capacity

                    250 A at 440 V for power circuit conforming to IEC 60947

                    [Icw] rated short-time withstand current

                  • 30 A 40 °C - 10 min for power circuit
                  • 61 A 40 °C - 1 min for power circuit
                  • 105 A 40 °C - 10 s for power circuit
                  • 210 A 40 °C - 1 s for power circuit
                  • 100 A - 1 s for signalling circuit
                  • 120 A - 500 ms for signalling circuit
                  • 140 A - 100 ms for signalling circuit
                    • Associated fuse rating

                    • 10 A gG for signalling circuit conforming to IEC 60947-5-1
                    • 40 A gG at <= 690 V coordination type 1 for power circuit
                    • 25 A gG at <= 690 V coordination type 2 for power circuit
                      • Average impedance

                        2.5 mOhm - Ith 25 A 50 Hz for power circuit

                        [Ui] rated insulation voltage

                      • power circuit: 600 V CSA certified
                      • power circuit: 600 V UL certified
                      • signalling circuit: 690 V conforming to IEC 60947-1
                      • signalling circuit: 600 V CSA certified
                      • signalling circuit: 600 V UL certified
                      • power circuit: 690 V conforming to IEC 60947-4-1
                        • Power dissipation per pole

                          1.56 W AC-1

                          Protective cover

                          with

                          Tightening torque

                        • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
                        • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
                        • power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
                        • power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
                          • Operating time

                          • 16...24 ms opening
                          • 53.55...72.45 ms closing
                            • Safety reliability level

                            • B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
                            • B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
                              • Maximum operating rate

                                3600 cyc/h 60 °C

                                Coil technology

                                built-in bidirectional peak limiting diode suppressor

                                Control circuit voltage limits

                              • 0.1...0.25 Uc (-40-70 °C):drop-out DC
                              • 0.7...1.25 Uc (-40-60 °C):operational DC
                              • 1...1.25 Uc (60-70 °C):operational DC
                                • Time constant

                                  28 ms

                                  Inrush power in W

                                  5.4-5.4 W (at 20 °C)

                                  Hold-in power consumption in W

                                  5.4-5.4 W at 20 °C

                                  Auxiliary contacts type

                                • type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
                                • type mirror contact 1 NC conforming to IEC 60947-4-1
                                  • Signalling circuit frequency

                                    25...400 Hz

                                    Minimum switching current

                                    5 mA for signalling circuit

                                    Minimum switching voltage

                                    17 V for signalling circuit

                                    Non-overlap time

                                  • 1.5 ms on de-energisation between NC and NO contact
                                  • 1.5 ms on energisation between NC and NO contact
                                    • Contact compatibility

                                      M7

                                      Compatibility code

                                      LC1D

                                      Protective treatment

                                      TH conforming to IEC 60068-2-30

                                      Pollution degree

                                      3

                                      Operating altitude

                                      0...3000 m

                                      Fire resistance

                                      850 °C conforming to IEC 60695-2-1

                                      Flame retardance

                                      V1 conforming to UL 94

                                      Mechanical robustness

                                    • vibrations contactor open: 2 Gn, 5...300 Hz
                                    • vibrations contactor closed: 4 Gn, 5...300 Hz
                                    • shocks contactor closed: 15 Gn for 11 ms
                                    • shocks contactor open: 10 Gn for 11 ms
                                      • Unit Type of Package 1

                                        PCE

                                        Number of Units in Package 1

                                        1

                                        Package 1 Weight

                                        558 g

                                        Package 1 Height

                                        5.6 cm

                                        Package 1 width

                                        12 cm

                                        Package 1 Length

                                        9.2 cm

                                        Unit Type of Package 2

                                        S02

                                        Number of Units in Package 2

                                        15

                                        Package 2 Weight

                                        8.675 kg

                                        Package 2 Height

                                        15 cm

                                        Package 2 width

                                        30 cm

                                        Package 2 Length

                                        40 cm

                                        Unit Type of Package 3

                                        P06

                                        Number of Units in Package 3

                                        240

                                        Package 3 Weight

                                        147.3 kg

                                        Package 3 Height

                                        77 cm

                                        Package 3 width

                                        80 cm

                                        Package 3 Length

                                        60 cm

                                        WEEE

                                        The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

                                        PVC free

                                        Yes
                                        Show all specifications

                                        Documents & downloads

                                        hide show
                                        Filter items
                                        • All

                                        • CAD Files and Packs

                                        • Product Brochures

                                        • Technical Data Catalogues

                                        • Product Environmental

                                        • End of Life Manual

                                        • Installation Instruction

                                        • Data Bulletin

                                        • Technical Drawing

                                        • Certificates (MSDS)

                                        • Declaration of Conformity

                                        Frequently Asked Questions

                                        hide show

                                        What is the power terminal lug data for the LC1D09, LC1DT20, LC1D12, and LC1DT25 contactor?

                                        Issue:
                                        Power terminal lug data required for the 9 and 12 amp rated Tesys D contactors

                                        Product Line:
                                        IEC Contactors and Starters

                                        Environment:
                                        Tesys D Contactors

                                        Resolution:
                                        For contactors with screw clamp terminals:
                                        stranded cable w/o cable end : One or Two #18-10 AWG per terminal.
                                        stranded cable w/cable end: One or Two #18-10 AWG per terminal.
                                        solid cable: One or Two #18-8 AWG per terminal.

                                        What does the T indicate in the LC1DT contactor catalog number?

                                        Issue:
                                        LC1DT catalog numbers

                                        Product Line:
                                        IEC Contactors and Starter

                                        Environment:
                                        Tesys D line Contactors

                                        Resolution:
                                        The T indicates that the device is a 4 poles with all normally open poles.  4 pole units only have resistive (AC-1) power contact ratings.

                                        What is the Part Number for the Mechanical Interlock for the 4-pole LC1DT20, LC1DT25, LC1DT32, and LC1DT40 Contactors?

                                        Issue:
                                        Four-pole IEC contactors needs the part number for the mechanical interlock

                                        Product Line:
                                        IEC Contactors

                                        Environment:
                                        Tesys D contactors

                                        Resolution:
                                        LADT9R1 is the mechanical interlock and power wiring only. The LADT9RV1 also includes an electrical interlock (2 NC contacts).

                                        What is the coil tolerance for Tesys D-line contactors LC1D09 - LC1D38?

                                        Issue:
                                        LC1D09 - LC1D38 Coil tolerance

                                        Product Line:
                                        Contactors and Starters, IEC

                                        Environment:
                                        Tesys D Contactors

                                        Cause:
                                        Needs the coil tolerance for Tesys D-line contactors LC1D09 - LC1D38.

                                        Resolution:
                                        AC single frequency coils: 50Hz and 60 Hz (-20% / +10%);
                                        AC dual frequency coils: 50Hz (-20% / +10%) ; 60Hz (-15% / +10%)
                                        DC standard coil for LC1D09 -D38 and LC1DT20 to DT40: (-30% / +25%)
                                        DC standard coil for LP1D12 and D25: (-20% / +10%)
                                        DC wide range coil for LP1D12 and D25 : (-30% to +25%)

                                        Can the single pole LA1DN and LADN auxiliary contact module be mounted on the TeSys contactors?

                                        ISSUE
                                        In which contactors can the LA1DN and LADN auxiliary contacts be mounted?

                                        PRODUCT LINE
                                        Auxiliary contacts for the Tesys D line

                                        ENVIRONMENT
                                        Tesys D-Line and Tesys F

                                        RESOLUTION
                                        These contacts will only fit on the following contactors:
                                        Front mount only for LC1D40 through LC1D115 devices and LC1D40A - LC1D65A.
                                        Left side mount only to LC1F contactors

                                        Where do I find the Coil voltage on the Tesys D 3 Pole AC Contactor?

                                        On the Tesys D 3 Pole AC Contactor you will find the coil voltage marked at the top, behind the Power terminals of the Contactor, for example U7, 240V 50/60 Hz

                                        For the DC Version, the coil voltage is marked on the front of the Contactor. Hence it has got complete part number for the Contactor on the front, for example: LC1D25BD for 24V DC Coil.




                                         
                                        Show More