TeSys model d  4 pole contactor
TeSys LC1DT contactor  4 poles  screw clamp terminals or lugs  with cover  20A to 40A
TeSys model d  4 pole contactor
TeSys LC1DT contactor  4 poles  screw clamp terminals or lugs  with cover  20A to 40A

TeSys D Contactor, 4P(4 NO), AC-1, <= 440V, 25A, 24VDC, Standard Coil

Catalogue Number: LC1DT25BD
TeSys model d  4 pole contactor
TeSys LC1DT contactor  4 poles  screw clamp terminals or lugs  with cover  20A to 40A
TeSys model d  4 pole contactor
TeSys LC1DT contactor  4 poles  screw clamp terminals or lugs  with cover  20A to 40A
Retail
$890.57*
RRP (Inc. GST)

Specifications

hide show
Range of product
TeSys D
Range
TeSys
Product name
TeSys D
Product or component type
contactor
Device short name
LC1D
Contactor application
resistive load
Utilisation category
AC-1
Poles description
4P
Pole contact composition
4 NO
[Ue] rated operational voltage
  • power circuit: <= 690 V AC 25...400 Hz
  • power circuit: <= 300 V DC
    • [Ie] rated operational current
      25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
      Control circuit type
      DC standard
      [Uc] control circuit voltage
      24 V DC
      Auxiliary contact composition
      1 NO + 1 NC
      [Uimp] rated impulse withstand voltage
      6 kV conforming to IEC 60947
      Overvoltage category
      III
      [Ith] conventional free air thermal current
    • 10 A (at 60 °C) for signalling circuit
    • 25 A (at 60 °C) for power circuit
      • Irms rated making capacity
      • 140 A AC for signalling circuit conforming to IEC 60947-5-1
      • 250 A DC for signalling circuit conforming to IEC 60947-5-1
      • 250 A at 440 V for power circuit conforming to IEC 60947
        • Rated breaking capacity
          250 A at 440 V for power circuit conforming to IEC 60947
          [Icw] rated short-time withstand current
        • 30 A 40 °C - 10 min for power circuit
        • 61 A 40 °C - 1 min for power circuit
        • 105 A 40 °C - 10 s for power circuit
        • 210 A 40 °C - 1 s for power circuit
        • 100 A - 1 s for signalling circuit
        • 120 A - 500 ms for signalling circuit
        • 140 A - 100 ms for signalling circuit
          • Associated fuse rating
          • 10 A gG for signalling circuit conforming to IEC 60947-5-1
          • 40 A gG at <= 690 V coordination type 1 for power circuit
          • 25 A gG at <= 690 V coordination type 2 for power circuit
            • Average impedance
              2.5 mOhm - Ith 25 A 50 Hz for power circuit
              [Ui] rated insulation voltage
            • power circuit: 600 V CSA certified
            • power circuit: 600 V UL certified
            • signalling circuit: 690 V conforming to IEC 60947-1
            • signalling circuit: 600 V CSA certified
            • signalling circuit: 600 V UL certified
            • power circuit: 690 V conforming to IEC 60947-4-1
              • Electrical durability
                0.8 Mcycles 25 A AC-1 at Ue <= 440 V
                Power dissipation per pole
                1.56 W AC-1
                Protective cover
                with
                Mounting support
              • rail
              • plate
                • Standards
                • CSA C22.2 No 14
                • EN 60947-4-1
                • EN 60947-5-1
                • IEC 60947-4-1
                • IEC 60947-5-1
                • UL 508
                  • Product certifications
                  • CCC
                  • GL
                  • BV
                  • LROS (Lloyds register of shipping)
                  • CSA
                  • DNV
                  • RINA
                  • UL
                  • GOST
                    • Connections - terminals
                    • control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end
                    • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end
                    • control circuit: screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end
                    • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible with cable end
                    • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²solid without cable end
                    • control circuit: screw clamp terminals 2 cable(s) 1-4 mm²solid without cable end
                    • power circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end
                    • power circuit: screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end
                    • power circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible with cable end
                    • power circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end
                    • power circuit: screw clamp terminals 1 cable(s) 1-4 mm²solid without cable end
                    • power circuit: screw clamp terminals 2 cable(s) 1-4 mm²solid without cable end
                      • Tightening torque
                      • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
                      • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
                      • power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
                      • power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
                        • Operating time
                        • 16...24 ms opening
                        • 53.55...72.45 ms closing
                          • Safety reliability level
                          • B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
                          • B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
                            • Mechanical durability
                              30 Mcycles
                              Maximum operating rate
                              3600 cyc/h 60 °C
                              Coil technology
                              built-in bidirectional peak limiting diode suppressor
                              Control circuit voltage limits
                            • drop-out: 0.1...0.25 Uc DC (at 60 °C)
                            • operational: 0.7...1.25 Uc DC (at 60 °C)
                              • Time constant
                                28 ms
                                Inrush power in W
                                5.4-5.4 W (at 20 °C)
                                Hold-in power consumption in W
                                5.4-5.4 W at 20 °C
                                Auxiliary contacts type
                              • type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
                              • type mirror contact 1 NC conforming to IEC 60947-4-1
                                • Signalling circuit frequency
                                  25...400 Hz
                                  Minimum switching current
                                  5 mA for signalling circuit
                                  Minimum switching voltage
                                  17 V for signalling circuit
                                  Non-overlap time
                                • 1.5 ms on de-energisation between NC and NO contact
                                • 1.5 ms on energisation between NC and NO contact
                                  • Insulation resistance
                                    > 10 MOhm for signalling circuit
                                    Contact compatibility
                                    M7
                                    Compatibility code
                                    LC1D
                                    IP degree of protection
                                    IP20 front face conforming to IEC 60529
                                    Protective treatment
                                    TH conforming to IEC 60068-2-30
                                    Pollution degree
                                    3
                                    Ambient air temperature for operation
                                    -5-60 °C
                                    Ambient air temperature for storage
                                    -60-80 °C
                                    Permissible ambient air temperature around the device
                                    -40-70 °C at Uc
                                    Operating altitude
                                    3000 m without
                                    Fire resistance
                                    850 °C conforming to IEC 60695-2-1
                                    Flame retardance
                                    V1 conforming to UL 94
                                    Mechanical robustness
                                  • vibrations contactor open: 2 Gn, 5...300 Hz
                                  • vibrations contactor closed: 4 Gn, 5...300 Hz
                                  • shocks contactor closed: 15 Gn for 11 ms
                                  • shocks contactor open: 10 Gn for 11 ms
                                    • Height
                                      85 mm
                                      Width
                                      45 mm
                                      Depth
                                      99 mm
                                      Net weight
                                      0.365 kg
                                      Sustainable offer status
                                      Green Premium product
                                      REACh Regulation
                                      Free of Substances of Very High Concern above the threshold
                                      EU RoHS Directive
                                      Compliant
                                      Mercury free
                                      Yes
                                      RoHS exemption information
                                      Yes
                                      China RoHS Regulation
                                      Product out of China RoHS scope. Substance declaration for your information
                                      Environmental Disclosure
                                      ENVPEP110230EN
                                      Circularity Profile
                                      ENVEOLI1102030EN
                                      WEEE
                                      The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                                      California proposition 65
                                      WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.gov
                                      Warranty
                                      18 months

                                      Documents & downloads

                                      hide show
                                      Filter items
                                      • All

                                      • CAD Files and Packs

                                      • Product Brochures

                                      • Technical Data Catalogues

                                      • End of Life Manual

                                      • Product Environmental

                                      • Installation Instruction

                                      • Data Bulletin

                                      • Certificates (MSDS)

                                      • Declaration of Conformity

                                      Frequently Asked Questions

                                      hide show

                                      What is the replacement coil part number for the LC*D09 through LC*D32 and LC*DT20 through LC*DT40 TeSys contactors?

                                      Issue:
                                      Identifying replacement coils for tesys D non-reversing and reversing conactors

                                      Product Line:
                                      IEC Contactors and Starters

                                      Environment:
                                      Products sold and used in the United States

                                      Cause:
                                      Replacement coil is needed

                                      Resolution:
                                      DC replacement coils are not available.
                                      AC Coils are 50/60 hertz for voltages as listed below:

                                      Volts - Part Number
                                      12 ____ LXD1J7
                                      21 ____ LXD1Z7
                                      24 ____ LXD1B7
                                      32 ____ LXD1C7
                                      36 ____ LXD1CC7
                                      42 ____ LXD1D7
                                      48 ____ LXD1E7
                                      60 ____ LXD1EE7
                                      100 ___ LXD1K7 ( never brought to North America )
                                      110 ___ LXD1F7
                                      115 ___ LXD1FE7
                                      120 ___ LXD1G7
                                      127 ___ LXD1FC7
                                      200 ___ LXD1L7
                                      208 ___ LXD1LE7
                                      220 ___ LXD1M7
                                      230 ___ LXD1P7
                                      240 ___ LXD1U7
                                      277 ___ LXD1W7
                                      380 ___ LXD1Q7
                                      400 ___ LXD1V7
                                      415 ___ LXD1N7
                                      440 ___ LXD1R7
                                      480 ___ LXD1T7
                                      575 ___ LXD1SC7
                                      600 ___ LXD1X7
                                      690 ___ LXD1Y7


                                      Note: A contactor with an AC coil can be changed to a different AC voltage coil, IE you can take an LC1D09 with a 120VAC coil and put a 24VAC coil in it instead. An AC device cannot be switched to a DC coil, and a DC device cannot be switches to an AC coil. 

                                      What is the maximum UL/CSA AC voltage rating of the LC1D power contacts ?

                                      Issue:
                                      Identifying maximum voltage of an LC1D contactor

                                      Product Line:
                                      TeSys D Contactors

                                      Environment:
                                      IEC contactors and starters used in North America

                                      Cause:
                                      n/a

                                      Resolution:
                                      IThe maximum voltage per UL and CSA is 600VAC. 
                                       

                                      Where are the control coil terminals for TeSys LC1D09 to LC1D38 contactor?

                                      Issue:
                                      Determine the control coil terminal marking and location on LC1D09 to LC1D38 contactor

                                      Product Line: 
                                      Tesys D Contactors

                                      Environment:
                                      IEC contactors

                                      Resolution:
                                      The coil terminals are marked A1 and A2, you can see them on the front of the contactor on the white part (control section).  They are next to the auxiliary contact (13/14, 21/22) terminals.
                                       

                                      What is the altitude derating for a TeSys D-Line contactor?

                                      Issue:​
                                      What is the altitude derating for a TeSys D-Line contactor?

                                      Product Line:
                                      Digest 177 Section 18 : Contactors and Starters, IEC

                                      Environment:
                                      North American Products

                                      Resolution:
                                      The contactors are fully rated up to 3000 meters. Following are derating multipliers for altitudes above 3000 meters for both voltage and current:

                                      Voltage
                                      3500m x 0.90
                                      4000m x 0.80
                                      4500m x 0.70
                                      5000m x 0.60

                                      Current
                                      3500m x 0.92
                                      4000m x 0.90
                                      4500m x 0.88
                                      5000m x 0.86

                                      For example, an LC1D80 at 5000 meters:
                                      - The maximum rated operational voltage is 1,000V (IEC947-4) and 690V (UL/CSA). At 5000 meters it becomes 1000V x 0.6 = 600V (IEC947-4) and 690V x 0.6 = 414V (UL/CSA).
                                      - The maximum rated operational AC3 current is 80A. At 5000 meters it becomes 80A x 0.86 = 68A.



                                       

                                      Can a GV2AF3 or GV2AF4 interconnection block work on a contactor with a DC coil?

                                      Issue:
                                      Mounting adaptor for GV2 and LC1D contactor

                                      Product Line:
                                      Motor Starters and Protectors

                                      Environment:
                                      TeSys GV Manual Starter and Protectors
                                      Tesys D Contactors
                                       
                                      Resolution:
                                      The GV2AF3 clip has to be moved to the DC position to accommodate the contactor with a DC coil.

                                      What is the power terminal lug data for the LC1D09, LC1DT20, LC1D12, and LC1DT25 contactor?

                                      Issue:
                                      Power terminal lug data required for the 9 and 12 amp rated Tesys D contactors

                                      Product Line:
                                      NEMA combination starters

                                      Environment:
                                      Products sold and used in the United States

                                      Resolution:
                                      For contactors with screw clamp terminals:
                                      stranded cable w/o cable end : One or Two #18-10 AWG per terminal.
                                      stranded cable w/cable end: One or Two #18-10 AWG per terminal.
                                      solid cable: One or Two #18-8 AWG per terminal.

                                      What is the difference between the LAD4TB and LAD4TBDL bi-directional peak limiting diode?

                                      Issue:
                                      Identifying the difference between LAD4TB and LAD4TBDL

                                      Product Line:
                                      IEC contactors and starters

                                      Environment:
                                      Products sold and used in the United States

                                      Cause:
                                      Identifying the difference between two similar part numbers

                                      Resolution:
                                      The LAD4TB is for 24V AC coils for the Tesys Series LC1D09 through LC1D38 contactors when supplied with G7 voltage code. The LAD4TBDL is 24 vdc bi-directional diode offered as a replacement if for some reason the diode supplied with the Tesys LC1D09 through LC1D38 contactors when ordered with BD or BL voltage code breaks or is no longer working.


                                       

                                      What replaces LC1D50BD

                                      Replacement LC1D50ABD

                                      What is the coil burden for the standard DC control coil for the LC*D09__ through LC*D38__ TeSys contactors?

                                      Issue:
                                      LC*D09-38 coil consumption

                                      Product Line:
                                      Contactors and Overload Relays

                                      Environment:
                                      TeSys™ D Contactors and Overload Relays

                                      Resolution:
                                      The standard DC coil is 5.4 watts of consumption.

                                      What is the color scheme of the Tesys D-Line contactors?

                                      Issue:
                                      Looking for different color scheme of the Tesys D-Line contactors.

                                      Product Line:
                                      Tesys D Contactors

                                      Environment:
                                      LC1D contactors

                                      Resolution:
                                      Beige and dark gray.
                                       

                                      What is the power terminal lug data for the LC1D40, LC1D50, LC1D65, LP1D40, LP1D50, and LP1D65 contactor?

                                      Issue:
                                      Identifying power terminal lug data for the D2 style contactors

                                      Product Line:
                                      Tesys D line contactors

                                      Environment:
                                      Products sold and used in the United States

                                      Cause:
                                      Power terminal lug data required

                                      Resolution:
                                      For contactors with screw clamp terminals:
                                      stranded cable w/o cable end : One #10-3 AWG or Two #10-4 AWG per terminal.
                                      stranded cable w/cable end: One #10-4 AWG or Two #12-2 AWG per terminal.
                                      solid cable: One #10-3 AWG or Two #10-6 AWG per terminal.

                                      What is the part number for the spacer used with the LC*D09 through LC*D32 Contactor and the GV2AF3 combination block when the GV2 Motor Circuit Protector is mounted on din rail and the contactor hangs below it?

                                      Issue:
                                      Identifying the spacer part number for use with a LC*D, GV2AF3, and GV2 device combination

                                      Product Line:
                                      Contactors and Starters IEC

                                      Environment:
                                      Tesys D contactors and GV manual starters

                                      Cause:
                                      Spacer required

                                      Resolution:
                                      Compensation plate catalog number GV1F03, requires 2 pieces snap together.
                                      Show More