Quantcast

TeSys D Contactor, 3P(3 NO), AC-3, <= 440V, 80A, 120VAC, 60 Hz Coil

TeSys D Contactor, 3P(3 NO), AC-3, <= 440V, 80A, 120VAC, 60 Hz Coil

TeSys D Contactor, 3P(3 NO), AC-3, <= 440V, 80A, 120VAC, 60 Hz Coil

Item Number: LC1D80G6

Retail
$2,517.39
RRP (Inc. GST)

Product Dimensions

Width icon

Width85 mm

Height icon

Height127 mm

Depth icon

Depth130 mm

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

TeSys D

Range

TeSys

Product or component type

contactor

Sustainable offer status

Green Premium product

Warranty

18 months

Physical

[Ue] rated operational voltage

  • power circuit: <= 300 V DC 25...400 Hz
  • power circuit: <= 690 V AC
    • [Ie] rated operational current

    • 125 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
    • 80 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
      • Electrical durability

      • 0.8 Mcycles 125 A AC-1 at Ue <= 440 V
      • 1.5 Mcycles 80 A AC-3 at Ue <= 440 V
        • Mounting support

        • rail
        • plate
          • Standards

          • CSA C22.2 No 14
          • EN 60947-4-1
          • EN 60947-5-1
          • IEC 60947-4-1
          • IEC 60947-5-1
          • UL 508
            • Product certifications

            • BV
            • GL
            • RINA
            • GOST
            • LROS (Lloyds register of shipping)
            • UL
            • CSA
            • DNV
            • CCC
              • Connections - terminals

              • control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end
              • control circuit: screw clamp terminals 1 cable(s) 1-2.5 mm²flexible with cable end
              • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end
              • control circuit: screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end
              • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²solid without cable end
              • control circuit: screw clamp terminals 2 cable(s) 1-4 mm²solid without cable end
              • power circuit: connector 1 cable(s) 4-50 mm²flexible without cable end
              • power circuit: connector 2 cable(s) 4-25 mm²flexible without cable end
              • power circuit: connector 1 cable(s) 4-50 mm²flexible with cable end
              • power circuit: connector 2 cable(s) 4-16 mm²flexible with cable end
              • power circuit: connector 1 cable(s) 4-50 mm²solid without cable end
              • power circuit: connector 2 cable(s) 4-25 mm²solid without cable end
                • Mechanical durability

                  10 Mcycles

                  Insulation resistance

                  > 10 MOhm for signalling circuit

                  IP degree of protection

                  IP20 front face conforming to IEC 60529

                  Ambient air temperature for operation

                • -40-60 °C
                • 60-70 °C with derating
                  • Ambient air temperature for storage

                    -60-80 °C

                    Height

                    127 mm

                    Width

                    85 mm

                    Depth

                    130 mm

                    Net weight

                    1.59 kg

                    REACh Regulation

                    Free of Substances of Very High Concern above the threshold

                    REACh free of SVHC

                    Yes

                    EU RoHS Directive

                    Compliant

                    Toxic heavy metal free

                    Yes

                    Mercury free

                    Yes

                    RoHS exemption information

                    Yes

                    China RoHS Regulation

                     Pro-active China RoHS declaration (out of China RoHS legal scope)

                    Environmental Disclosure

                    ENVPEP110205EN

                    California proposition 65

                    WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov

                    Others

                    Product name

                    TeSys D

                    Device short name

                    LC1D

                    Contactor application

                  • motor control
                  • resistive load
                    • Utilisation category

                    • AC-3
                    • AC-1
                    • AC-4
                      • Poles description

                        3P

                        Pole contact composition

                        3 NO

                        Motor power kW

                      • 22 kW at 220...230 V AC 50/60 Hz (AC-3)
                      • 37 kW at 380...400 V AC 50/60 Hz (AC-3)
                      • 45 kW at 415...440 V AC 50/60 Hz (AC-3)
                      • 55 kW at 500 V AC 50/60 Hz (AC-3)
                      • 45 kW at 660...690 V AC 50/60 Hz (AC-3)
                      • 45 kW at 1000 V AC 50/60 Hz (AC-3)
                      • 15 kW at 400 V AC 50/60 Hz (AC-4)
                        • Motor power hp

                        • 20 hp at 200/208 V AC 50/60 Hz for 3 phases motors
                        • 7.5 hp at 115 V AC 50/60 Hz for 1 phase motors
                        • 15 hp at 230/240 V AC 50/60 Hz for 1 phase motors
                        • 25 hp at 230/240 V AC 50/60 Hz for 3 phases motors
                        • 60 hp at 460/480 V AC 50/60 Hz for 3 phases motors
                        • 60 hp at 575/600 V AC 50/60 Hz for 3 phases motors
                          • Control circuit type

                            AC at 60 Hz

                            [Uc] control circuit voltage

                            120 V AC 60 Hz

                            Auxiliary contact composition

                            1 NO + 1 NC

                            [Uimp] rated impulse withstand voltage

                            8 kV conforming to IEC 60947

                            Overvoltage category

                            III

                            [Ith] conventional free air thermal current

                          • 10 A (at 60 °C) for signalling circuit
                          • 125 A (at 60 °C) for power circuit
                            • Irms rated making capacity

                            • 140 A AC for signalling circuit conforming to IEC 60947-5-1
                            • 250 A DC for signalling circuit conforming to IEC 60947-5-1
                            • 1100 A at 440 V for power circuit conforming to IEC 60947
                              • Rated breaking capacity

                                1100 A at 440 V for power circuit conforming to IEC 60947

                                [Icw] rated short-time withstand current

                              • 640 A 40 °C - 10 s for power circuit
                              • 990 A 40 °C - 1 s for power circuit
                              • 135 A 40 °C - 10 min for power circuit
                              • 320 A 40 °C - 1 min for power circuit
                              • 100 A - 1 s for signalling circuit
                              • 120 A - 500 ms for signalling circuit
                              • 140 A - 100 ms for signalling circuit
                                • Associated fuse rating

                                • 10 A gG for signalling circuit conforming to IEC 60947-5-1
                                • 200 A gG at <= 690 V coordination type 1 for power circuit
                                • 160 A gG at <= 690 V coordination type 2 for power circuit
                                  • Average impedance

                                    0.8 mOhm - Ith 125 A 50 Hz for power circuit

                                    [Ui] rated insulation voltage

                                  • power circuit: 600 V CSA certified
                                  • power circuit: 600 V UL certified
                                  • power circuit: 1000 V conforming to IEC 60947-4-1
                                  • signalling circuit: 690 V conforming to IEC 60947-1
                                  • signalling circuit: 600 V CSA certified
                                  • signalling circuit: 600 V UL certified
                                    • Power dissipation per pole

                                    • 5.1 W AC-3
                                    • 12.5 W AC-1
                                      • Protective cover

                                        with

                                        Tightening torque

                                      • control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
                                      • control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2
                                      • power circuit: 12 N.m - on connector - with screwdriver flat Ø 6 to Ø 8 mm
                                      • power circuit: 12 N.m - on connector hexagonal screw head 4 mm
                                        • Operating time

                                        • 20...35 ms closing
                                        • 6...20 ms opening
                                          • Safety reliability level

                                          • B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
                                          • B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
                                            • Maximum operating rate

                                              3600 cyc/h 60 °C

                                              Coil technology

                                              without built-in suppressor module

                                              Control circuit voltage limits

                                            • 0.85...1.1 Uc (-40-55 °C):operational AC 60 Hz
                                            • 0.3...0.6 Uc (-40-70 °C):drop-out AC 60 Hz
                                            • 1...1.1 Uc (55-70 °C):operational AC 60 Hz
                                              • Inrush power in VA

                                                220-220 VA 60 Hz cos phi 0.75 (at 20 °C)

                                                Hold-in power consumption in VA

                                                22-22 VA 60 Hz cos phi 0.3 (at 20 °C)

                                                Heat dissipation

                                                6-10 W at 60 Hz

                                                Auxiliary contacts type

                                              • type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
                                              • type mirror contact 1 NC conforming to IEC 60947-4-1
                                                • Signalling circuit frequency

                                                  25...400 Hz

                                                  Minimum switching current

                                                  5 mA for signalling circuit

                                                  Minimum switching voltage

                                                  17 V for signalling circuit

                                                  Non-overlap time

                                                • 1.5 ms on de-energisation between NC and NO contact
                                                • 1.5 ms on energisation between NC and NO contact
                                                  • Contact compatibility

                                                    M12

                                                    Compatibility code

                                                    LC1D

                                                    Protective treatment

                                                    TH conforming to IEC 60068-2-30

                                                    Pollution degree

                                                    3

                                                    Operating altitude

                                                    0...3000 m

                                                    Fire resistance

                                                    850 °C conforming to IEC 60695-2-1

                                                    Flame retardance

                                                    V1 conforming to UL 94

                                                    Mechanical robustness

                                                  • vibrations contactor open: 2 Gn, 5...300 Hz
                                                  • shocks contactor open: 8 Gn for 11 ms
                                                  • vibrations contactor closed: 3 Gn, 5...300 Hz
                                                  • shocks contactor closed: 10 Gn for 11 ms
                                                    • Unit Type of Package 1

                                                      PCE

                                                      Number of Units in Package 1

                                                      1

                                                      Package 1 Weight

                                                      1.54 kg

                                                      Package 1 Height

                                                      13.5 cm

                                                      Package 1 width

                                                      10.5 cm

                                                      Package 1 Length

                                                      13.5 cm

                                                      WEEE

                                                      The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

                                                      PVC free

                                                      Yes
                                                      Show all specifications

                                                      Documents & downloads

                                                      hide show
                                                      Filter items
                                                      • All

                                                      • Product Brochures

                                                      • CAD Files and Packs

                                                      • Installation Instruction

                                                      • Data Bulletin

                                                      • Product Environmental

                                                      • Declaration of Conformity

                                                      • Certificates (MSDS)