TeSys LC1D contactor, 3 poles, screw clamp terminals or connectors, cover, 80A to 95A

TeSys D Contactor, 3P(3 NO), AC-3, <= 440V, 80A, 32VAC, 50 Hz Coil

Catalogue Number: LC1D80C5
TeSys LC1D contactor, 3 poles, screw clamp terminals or connectors, cover, 80A to 95A
Retail
N/A
RRP (Inc. GST)

Specifications

hide show
Range of product
TeSys D
Range
TeSys
Product name
TeSys D
Product or component type
contactor
Device short name
LC1D
Contactor application
  • resistive load
  • motor control
    • Utilisation category
    • AC-3
    • AC-4
    • AC-1
      • Poles description
        3P
        Pole contact composition
        3 NO
        [Ue] rated operational voltage
      • power circuit: <= 300 V DC 25...400 Hz
      • power circuit: <= 690 V AC
        • [Ie] rated operational current
        • 125 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
        • 80 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
          • Motor power kW
          • 22 kW at 220...230 V AC 50/60 Hz (AC-3)
          • 37 kW at 380...400 V AC 50/60 Hz (AC-3)
          • 45 kW at 415...440 V AC 50/60 Hz (AC-3)
          • 55 kW at 500 V AC 50/60 Hz (AC-3)
          • 45 kW at 660...690 V AC 50/60 Hz (AC-3)
          • 45 kW at 1000 V AC 50/60 Hz (AC-3)
          • 15 kW at 400 V AC 50/60 Hz (AC-4)
            • Motor power hp
            • 20 hp at 200/208 V AC 50/60 Hz for 3 phases motors
            • 7.5 hp at 115 V AC 50/60 Hz for 1 phase motors
            • 15 hp at 230/240 V AC 50/60 Hz for 1 phase motors
            • 25 hp at 230/240 V AC 50/60 Hz for 3 phases motors
            • 60 hp at 460/480 V AC 50/60 Hz for 3 phases motors
            • 60 hp at 575/600 V AC 50/60 Hz for 3 phases motors
              • Control circuit type
                AC at 50 Hz
                [Uc] control circuit voltage
                32 V AC 50 Hz
                Auxiliary contact composition
                1 NO + 1 NC
                [Uimp] rated impulse withstand voltage
                8 kV conforming to IEC 60947
                Overvoltage category
                III
                [Ith] conventional free air thermal current
              • 10 A (at 60 °C) for signalling circuit
              • 125 A (at 60 °C) for power circuit
                • Irms rated making capacity
                • 140 A AC for signalling circuit conforming to IEC 60947-5-1
                • 250 A DC for signalling circuit conforming to IEC 60947-5-1
                • 1100 A at 440 V for power circuit conforming to IEC 60947
                  • Rated breaking capacity
                    1100 A at 440 V for power circuit conforming to IEC 60947
                    [Icw] rated short-time withstand current
                  • 640 A 40 °C - 10 s for power circuit
                  • 990 A 40 °C - 1 s for power circuit
                  • 135 A 40 °C - 10 min for power circuit
                  • 320 A 40 °C - 1 min for power circuit
                  • 100 A - 1 s for signalling circuit
                  • 120 A - 500 ms for signalling circuit
                  • 140 A - 100 ms for signalling circuit
                    • Associated fuse rating
                    • 10 A gG for signalling circuit conforming to IEC 60947-5-1
                    • 200 A gG at <= 690 V coordination type 1 for power circuit
                    • 160 A gG at <= 690 V coordination type 2 for power circuit
                      • Average impedance
                        0.8 mOhm - Ith 125 A 50 Hz for power circuit
                        [Ui] rated insulation voltage
                      • power circuit: 600 V CSA certified
                      • power circuit: 600 V UL certified
                      • power circuit: 1000 V conforming to IEC 60947-4-1
                      • signalling circuit: 690 V conforming to IEC 60947-1
                      • signalling circuit: 600 V CSA certified
                      • signalling circuit: 600 V UL certified
                        • Electrical durability
                        • 0.8 Mcycles 125 A AC-1 at Ue <= 440 V
                        • 1.5 Mcycles 80 A AC-3 at Ue <= 440 V
                          • Power dissipation per pole
                          • 5.1 W AC-3
                          • 12.5 W AC-1
                            • Protective cover
                              with
                              Mounting support
                            • rail
                            • plate
                              • Standards
                              • CSA C22.2 No 14
                              • EN 60947-4-1
                              • EN 60947-5-1
                              • IEC 60947-4-1
                              • IEC 60947-5-1
                              • UL 508
                                • Product certifications
                                • BV
                                • DNV
                                • CSA
                                • RINA
                                • CCC
                                • UL
                                • LROS (Lloyds register of shipping)
                                • GL
                                • GOST
                                  • Connections - terminals
                                  • control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end
                                  • control circuit: screw clamp terminals 1 cable(s) 1-2.5 mm²flexible with cable end
                                  • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end
                                  • control circuit: screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end
                                  • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²solid without cable end
                                  • control circuit: screw clamp terminals 2 cable(s) 1-4 mm²solid without cable end
                                  • power circuit: connector 1 cable(s) 4-50 mm²flexible without cable end
                                  • power circuit: connector 2 cable(s) 4-25 mm²flexible without cable end
                                  • power circuit: connector 1 cable(s) 4-50 mm²flexible with cable end
                                  • power circuit: connector 2 cable(s) 4-16 mm²flexible with cable end
                                  • power circuit: connector 1 cable(s) 4-50 mm²solid without cable end
                                  • power circuit: connector 2 cable(s) 4-25 mm²solid without cable end
                                    • Tightening torque
                                    • control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
                                    • control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2
                                    • power circuit: 9 N.m - on connector - with screwdriver flat Ø 6 to Ø 8 mm
                                    • power circuit: 9 N.m - on connector hexagonal screw head 4 mm
                                      • Operating time
                                      • 20...35 ms closing
                                      • 6...20 ms opening
                                        • Safety reliability level
                                        • B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
                                        • B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
                                          • Mechanical durability
                                            10 Mcycles
                                            Maximum operating rate
                                            3600 cyc/h 60 °C
                                            Coil technology
                                            without built-in suppressor module
                                            Inrush power in VA
                                            200-200 VA 50 Hz cos phi 0.75 (at 20 °C)
                                            Hold-in power consumption in VA
                                            20-20 VA 50 Hz cos phi 0.3 (at 20 °C)
                                            Heat dissipation
                                            6-10 W at 50 Hz
                                            Auxiliary contacts type
                                          • type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
                                          • type mirror contact 1 NC conforming to IEC 60947-4-1
                                            • Signalling circuit frequency
                                              25...400 Hz
                                              Minimum switching current
                                              5 mA for signalling circuit
                                              Minimum switching voltage
                                              17 V for signalling circuit
                                              Non-overlap time
                                            • 1.5 ms on de-energisation between NC and NO contact
                                            • 1.5 ms on energisation between NC and NO contact
                                              • Insulation resistance
                                                > 10 MOhm for signalling circuit
                                                Contact compatibility
                                                M12
                                                Compatibility code
                                                LC1D
                                                IP degree of protection
                                                IP20 front face conforming to IEC 60529
                                                Protective treatment
                                                TH conforming to IEC 60068-2-30
                                                Pollution degree
                                                3
                                                Ambient air temperature for storage
                                                -60-80 °C
                                                Operating altitude
                                                3000 m without derating
                                                Fire resistance
                                                850 °C conforming to IEC 60695-2-1
                                                Flame retardance
                                                V1 conforming to UL 94
                                                Mechanical robustness
                                              • vibrations contactor open: 2 Gn, 5...300 Hz
                                              • shocks contactor open: 8 Gn for 11 ms
                                              • vibrations contactor closed: 3 Gn, 5...300 Hz
                                              • shocks contactor closed: 10 Gn for 11 ms
                                                • Height
                                                  127 mm
                                                  Width
                                                  85 mm
                                                  Depth
                                                  130 mm
                                                  Net weight
                                                  1.59 kg
                                                  Package 1 Weight
                                                  1.6 kg
                                                  Package 1 Height
                                                  1.55 dm
                                                  Package 1 width
                                                  0.95 dm
                                                  Package 1 Length
                                                  1.35 dm
                                                  Sustainable offer status
                                                  Green Premium product
                                                  REACh free of SVHC
                                                  Yes
                                                  EU RoHS Directive
                                                  Compliant
                                                  Toxic heavy metal free
                                                  Yes
                                                  Mercury free
                                                  Yes
                                                  RoHS exemption information
                                                  Yes
                                                  China RoHS Regulation
                                                   Pro-active China RoHS declaration (out of China RoHS legal scope)
                                                  Environmental Disclosure
                                                  ENVPEP110205EN
                                                  WEEE
                                                  The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                                                  PVC free
                                                  Yes
                                                  Warranty
                                                  18 months

                                                  Documents & downloads

                                                  hide show
                                                  Filter items
                                                  • All

                                                  • CAD Files and Packs

                                                  • Product Brochures

                                                  • Product Environmental

                                                  • Installation Instruction

                                                  • Certificates (MSDS)

                                                  • Declaration of Conformity

                                                  Frequently Asked Questions

                                                  hide show

                                                  What is the altitude derating for a TeSys D-Line contactor?

                                                  Issue:​
                                                  What is the altitude derating for a TeSys D-Line contactor?

                                                  Product Line:
                                                  Digest 177 Section 18 : Contactors and Starters, IEC

                                                  Environment:
                                                  North American Products

                                                  Resolution:
                                                  The contactors are fully rated up to 3000 meters. Following are derating multipliers for altitudes above 3000 meters for both voltage and current:

                                                  Voltage
                                                  3500m x 0.90
                                                  4000m x 0.80
                                                  4500m x 0.70
                                                  5000m x 0.60

                                                  Current
                                                  3500m x 0.92
                                                  4000m x 0.90
                                                  4500m x 0.88
                                                  5000m x 0.86

                                                  For example, an LC1D80 at 5000 meters:
                                                  - The maximum rated operational voltage is 1,000V (IEC947-4) and 690V (UL/CSA). At 5000 meters it becomes 1000V x 0.6 = 600V (IEC947-4) and 690V x 0.6 = 414V (UL/CSA).
                                                  - The maximum rated operational AC3 current is 80A. At 5000 meters it becomes 80A x 0.86 = 68A.



                                                   

                                                  What is the maximum UL/CSA AC voltage rating of the LC1D power contacts ?

                                                  Issue:
                                                  Identifying maximum voltage of an LC1D contactor

                                                  Product Line:
                                                  TeSys D Contactors

                                                  Environment:
                                                  IEC contactors and starters used in North America

                                                  Cause:
                                                  n/a

                                                  Resolution:
                                                  IThe maximum voltage per UL and CSA is 600VAC. 
                                                   

                                                  What is the power terminal lug data for the LC1D40, LC1D50, LC1D65, LP1D40, LP1D50, and LP1D65 contactor?

                                                  Issue:
                                                  Identifying power terminal lug data for the D2 style contactors

                                                  Product Line:
                                                  Tesys D line contactors

                                                  Environment:
                                                  Products sold and used in the United States

                                                  Cause:
                                                  Power terminal lug data required

                                                  Resolution:
                                                  For contactors with screw clamp terminals:
                                                  stranded cable w/o cable end : One #10-3 AWG or Two #10-4 AWG per terminal.
                                                  stranded cable w/cable end: One #10-4 AWG or Two #12-2 AWG per terminal.
                                                  solid cable: One #10-3 AWG or Two #10-6 AWG per terminal.

                                                  What is the replacement AC coil for LC1D/LC2D40, D50, D65, D80, and D95?

                                                  Issue:
                                                  AC Coil information for LC1D/LC2D40, D50, D65, D80, and D95

                                                  Product Line:
                                                  Tesys D Replacement Parts

                                                  Environment:
                                                  TeSys™ D AC Coils

                                                  Resolution:

                                                  Will the LAD** time delay auxiliary contact module fit the D2 series pre-Tesys contactors?

                                                  Issue:
                                                  Can new accessories be used on older style contactors

                                                  Product Line:
                                                  IEC contactors and starters

                                                  Environment:
                                                  Products sold and used in the United States

                                                  Cause:
                                                  Identifying product compatibility

                                                  Resolution:
                                                  Yes, all front mount D2 and Tesys series auxiliary modules are backward forward compatible.


                                                   

                                                  Are the D-Line contactors rated to break DC voltages?

                                                  Issue: 
                                                  Can the TeSys D line be used to control DC loads? 

                                                  Product Line:
                                                  Tesys D contactors

                                                  Environment:
                                                  Products sold and used in the United States
                                                   
                                                  Cause:
                                                   DC power circuit
                                                   
                                                  Resolution:
                                                   
                                                  Yes, 75 VDC (125 VDC for D115 & D150) per pole which means that through a four pole device breaking 300 VDC is possible by wiring all four power poles in series. However, be aware that the device current ratings will differ according to the number of poles in series and the type of application.

                                                  Devices are suitable but not UL Listed for DC applications.

                                                  More information on their DC ratings can be found in the current TeSys Motor Control and Protection Compentns catalog: https://www.schneider-electric.us/en/download/document/MKTED210011EN/


                                                   

                                                  What is the replacement coil part number for the LC*D09 through LC*D32 and LC*DT20 through LC*DT40 TeSys contactors?

                                                  Issue:
                                                  Identifying replacement coils for tesys D non-reversing and reversing conactors

                                                  Product Line:
                                                  IEC Contactors and Starters

                                                  Environment:
                                                  Products sold and used in the United States

                                                  Cause:
                                                  Replacement coil is needed

                                                  Resolution:
                                                  DC replacement coils are not available.
                                                  AC Coils are 50/60 hertz for voltages as listed below:

                                                  Volts - Part Number
                                                  12 ____ LXD1J7
                                                  21 ____ LXD1Z7
                                                  24 ____ LXD1B7
                                                  32 ____ LXD1C7
                                                  36 ____ LXD1CC7
                                                  42 ____ LXD1D7
                                                  48 ____ LXD1E7
                                                  60 ____ LXD1EE7
                                                  100 ___ LXD1K7 ( never brought to North America )
                                                  110 ___ LXD1F7
                                                  115 ___ LXD1FE7
                                                  120 ___ LXD1G7
                                                  127 ___ LXD1FC7
                                                  200 ___ LXD1L7
                                                  208 ___ LXD1LE7
                                                  220 ___ LXD1M7
                                                  230 ___ LXD1P7
                                                  240 ___ LXD1U7
                                                  277 ___ LXD1W7
                                                  380 ___ LXD1Q7
                                                  400 ___ LXD1V7
                                                  415 ___ LXD1N7
                                                  440 ___ LXD1R7
                                                  480 ___ LXD1T7
                                                  575 ___ LXD1SC7
                                                  600 ___ LXD1X7
                                                  690 ___ LXD1Y7


                                                  Note: A contactor with an AC coil can be changed to a different AC voltage coil, IE you can take an LC1D09 with a 120VAC coil and put a 24VAC coil in it instead. An AC device cannot be switched to a DC coil, and a DC device cannot be switches to an AC coil. 

                                                  What is the part number for the contactor that replaces the LC1D50E5?

                                                  The part number for the contactor that replaces the LC1D50E5 is - LC1D50AE7

                                                  For further information , visit link below:-
                                                  https://www.schneider-electric.com.au/en/search/LC1D50AE7
                                                   

                                                  What are the part numbers of contactors in LE3AC075N7*

                                                  Part no LE3AC075N7 consists  Two  of LC1D80U7 and one of LC1D50U7 contactors.

                                                  What is the color scheme of the Tesys D-Line contactors?

                                                  Issue:
                                                  Looking for different color scheme of the Tesys D-Line contactors.

                                                  Product Line:
                                                  Tesys D Contactors

                                                  Environment:
                                                  LC1D contactors

                                                  Resolution:
                                                  Beige and dark gray.
                                                   

                                                  Is there a contactor 80A 3p which will operate on 42V AC

                                                   There is - part code LC1D80E7

                                                  Video: What auxiliary contact modules are available for the LC1D and LC2D contactors?

                                                  Issue:
                                                  Auxiliary contact modules for the LC1D and LC2D contactors

                                                  Product Line: 
                                                  Contactor and Starters - IEC

                                                  Environment:
                                                  North American Products

                                                  Resolution:
                                                  Select based on application requirements. Please note that the TeSys and Pre-TeSys auxiliary blocks are backward/forward compatible.
                                                  Front Mounting; maximum of 1 block per contactor:

                                                  N.O.-------N.C.-----TeSys P/N--------Pre-TeSys P/N
                                                  --1-----------1---------LADN11-----------LA1DN11
                                                  --1-----------1---------LADN11G---------LA1DN11G (See Footnote 1)
                                                  --1-----------1---------LADN11P---------LA1DN11P (See Footnote 1)
                                                  --2-----------0---------LADN20-----------LA1DN20
                                                  --2-----------0---------LA1DX20---------LA1DX20 (See Footnote 2)
                                                  --2-----------0---------LA1DY20---------LA1DY20 (See Footnote 3)
                                                  --0-----------2---------LADN02-----------LA1DN02
                                                  --2-----------2---------LADN22-----------LA1DN22
                                                  --2-----------2---------LADN22G---------LA1DN22G (See Footnote 1)
                                                  --2-----------2---------LADN22P---------LA1DN22P (See Footnote 1)
                                                  --2-----------2---------LADC22------------LA1DC22 (See Footnote 4)
                                                  --3-----------1---------LADN31------------LA1DN31
                                                  --3-----------1---------LA1DZ31----------LA1DZ31 (See Footnote 5)
                                                  --1-----------3---------LADN13------------LA1DN13
                                                  --4-----------0---------LADN40------------LA1DN40
                                                  --4-----------0---------LA1DZ40-----------LA1DZ40 (See Footnote 6)
                                                  --0-----------4---------LADN04------------LA1DN04




                                                  Front Mounting; maximum of 1 block per contactor: For use with D2 Series 25 amp through 80 amp contactors and TeSys Series 40 amp through 80 amp only.

                                                  N.O.-------N.C.-----TeSys P/N--------Pre-TeSys P/N
                                                  --1-----------0--------LADN10----------LA1DN10
                                                  --0-----------1--------LADN01----------LA1DN01

                                                  Side Mounting; maximum of 1 block on each side for D2 Series and Tesys Series 40 through 80 amp contactors. Tesys 9 through 32, 115, and 150 amps contactors will accept 1 block and is limited to left side only. (*) DC control devices will not accept side mount auxiliaries.
                                                  (*) DC control exceptions that will accept one left side mounted auxiliary: LC1D115 & LC1D150.

                                                  N.O.-------N.C.-----TeSys P/N--------Pre-TeSys P/N
                                                  --1-----------1--------LAD8N11----------LA8DN11
                                                  --2-----------0--------LAD8N20----------LA8DN20
                                                  --0-----------2--------LAD8N02----------N/A

                                                  Footnotes:
                                                  {1} EN50 012 Machine Tool Terminal Markings
                                                  {2} (2) NO Sealed Dust Tight Contacts
                                                  {3} Gold Flash Contacts
                                                  {4} (1) NO & (1) NC Standard and (1) NO & (1) NC Make Before Break
                                                  {5} (2) NO Dust Tight Contacts & (1) NO & (1) NC Standard Contacts
                                                  {6} (2) NO Dust Tight Contacts & (2) NO Standard Contacts
                                                  Show More