TeSys LC1D6500 contactor, 4 poles, screw clamp terminals or lugs, without cover, 80A
TeSys model d contactor
TeSys LC1D6500 contactor, 4 poles, screw clamp terminals or lugs, without cover, 80A
TeSys model d contactor

TeSys D Contactor, 4P(2 NO + 2 NC), AC-1, <= 440V, 80A, 48VAC, 50 Hz Coil

Catalogue Number: LC1D65008E5
TeSys LC1D6500 contactor, 4 poles, screw clamp terminals or lugs, without cover, 80A
TeSys model d contactor
TeSys LC1D6500 contactor, 4 poles, screw clamp terminals or lugs, without cover, 80A
TeSys model d contactor
Retail
$2,378.28
RRP (Inc. GST)

Specifications

hide show
Range of product
TeSys D
Range
TeSys
Product name
TeSys D
Product or component type
contactor
Device short name
LC1D
Contactor application
resistive load
Utilisation category
AC-1
Poles description
4P
Pole contact composition
2 NO + 2 NC
[Ue] rated operational voltage
  • power circuit: <= 690 V AC 25...400 Hz
  • power circuit: <= 300 V DC
    • [Ie] rated operational current
      80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
      Control circuit type
      AC at 50 Hz
      [Uc] control circuit voltage
      48 V AC 50 Hz
      [Uimp] rated impulse withstand voltage
      6 kV conforming to IEC 60947
      Overvoltage category
      III
      [Ith] conventional free air thermal current
      80 A (at 60 °C) for power circuit
      Irms rated making capacity
      1000 A at 440 V for power circuit conforming to IEC 60947
      Rated breaking capacity
      1000 A at 440 V for power circuit conforming to IEC 60947
      [Icw] rated short-time withstand current
    • 520 A 40 °C - 10 s for power circuit
    • 900 A 40 °C - 1 s for power circuit
    • 110 A 40 °C - 10 min for power circuit
    • 260 A 40 °C - 1 min for power circuit
      • Associated fuse rating
      • 125 A gG at <= 690 V coordination type 1 for power circuit
      • 125 A gG at <= 690 V coordination type 2 for power circuit
        • Average impedance
          1.5 mOhm - Ith 80 A 50 Hz for power circuit
          [Ui] rated insulation voltage
        • power circuit: 600 V CSA certified
        • power circuit: 600 V UL certified
        • power circuit: 690 V conforming to IEC 60947-4-1
          • Electrical durability
            1.4 Mcycles 80 A AC-1 at Ue <= 440 V
            Power dissipation per pole
            9.6 W AC-1
            Protective cover
            without
            Mounting support
          • plate
          • rail
            • Standards
            • CSA C22.2 No 14
            • EN 60947-4-1
            • EN 60947-5-1
            • IEC 60947-4-1
            • IEC 60947-5-1
            • UL 508
              • Product certifications
              • GL
              • GOST
              • LROS (Lloyds register of shipping)
              • BV
              • RINA
              • DNV
              • UL
              • CCC
              • CSA
                • Connections - terminals
                • control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end
                • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end
                • control circuit: screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end
                • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible with cable end
                • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²solid without cable end
                • control circuit: screw clamp terminals 2 cable(s) 1-4 mm²solid without cable end
                • power circuit: screw clamp terminals 1 cable(s) 1-35 mm²flexible without cable end
                • power circuit: screw clamp terminals 2 cable(s) 1-25 mm²flexible without cable end
                • power circuit: screw clamp terminals 1 cable(s) 1-35 mm²flexible with cable end
                • power circuit: screw clamp terminals 2 cable(s) 1-25 mm²flexible with cable end
                • power circuit: screw clamp terminals 1 cable(s) 1-35 mm²solid without cable end
                • power circuit: screw clamp terminals 2 cable(s) 1-25 mm²solid without cable end
                  • Tightening torque
                  • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
                  • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
                  • power circuit: 8 N.m - on screw clamp terminals - cable 25-35 mm² hexagonal screw head 4 mm
                  • power circuit: 5 N.m - on screw clamp terminals - cable 1-25 mm² hexagonal screw head 4 mm
                    • Operating time
                    • 4...19 ms opening
                    • 12...26 ms closing
                      • Safety reliability level
                      • B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
                      • B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
                        • Mechanical durability
                          6 Mcycles
                          Maximum operating rate
                          3600 cyc/h 60 °C
                          Coil technology
                          without built-in suppressor module
                          Inrush power in VA
                          160-160 VA 50 Hz cos phi 0.75 (at 20 °C)
                          Hold-in power consumption in VA
                          15-15 VA 50 Hz cos phi 0.3 (at 20 °C)
                          Heat dissipation
                          4-5 W at 50 Hz
                          Contact compatibility
                          M1
                          Compatibility code
                          LC1D
                          IP degree of protection
                          IP20 front face conforming to IEC 60529
                          Protective treatment
                          TH conforming to IEC 60068-2-30
                          Pollution degree
                          3
                          Ambient air temperature for storage
                          -60-80 °C
                          Operating altitude
                          3000 m without derating
                          Fire resistance
                          850 °C conforming to IEC 60695-2-1
                          Flame retardance
                          V1 conforming to UL 94
                          Mechanical robustness
                        • vibrations contactor open: 2 Gn, 5...300 Hz
                        • vibrations contactor closed: 4 Gn, 5...300 Hz
                        • shocks contactor closed: 15 Gn for 11 ms
                        • shocks contactor open: 10 Gn for 11 ms
                          • Height
                            127 mm
                            Width
                            85 mm
                            Depth
                            125 mm
                            Net weight
                            1.45 kg
                            Unit Type of Package 1
                            PCE
                            Number of Units in Package 1
                            1
                            Package 1 Weight
                            1.47 kg
                            Package 1 Height
                            9.5 cm
                            Package 1 width
                            13 cm
                            Package 1 Length
                            13.5 cm
                            Sustainable offer status
                            Green Premium product
                            REACh free of SVHC
                            Yes
                            EU RoHS Directive
                            Compliant
                            Toxic heavy metal free
                            Yes
                            Mercury free
                            Yes
                            RoHS exemption information
                            Yes
                            China RoHS Regulation
                             Pro-active China RoHS declaration (out of China RoHS legal scope)
                            Environmental Disclosure
                            ENVPEP1503009EN
                            Circularity Profile
                            ENVEOLI1503009EN
                            WEEE
                            The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                            PVC free
                            Yes
                            Warranty
                            18 months

                            Documents & downloads

                            hide show
                            Filter items
                            • All

                            • Product Brochures

                            • Technical Data Catalogues

                            • End of Life Manual

                            • Product Environmental

                            • Certificates (MSDS)

                            • Declaration of Conformity

                            Frequently Asked Questions

                            hide show

                            What is the power terminal lug data for the LC1D40, LC1D50, LC1D65, LP1D40, LP1D50, and LP1D65 contactor?

                            Issue:
                            Identifying power terminal lug data for the D2 style contactors

                            Product Line:
                            Tesys D line contactors

                            Environment:
                            Products sold and used in the United States

                            Cause:
                            Power terminal lug data required

                            Resolution:
                            For contactors with screw clamp terminals:
                            stranded cable w/o cable end : One #10-3 AWG or Two #10-4 AWG per terminal.
                            stranded cable w/cable end: One #10-4 AWG or Two #12-2 AWG per terminal.
                            solid cable: One #10-3 AWG or Two #10-6 AWG per terminal.

                            What is the maximum UL/CSA AC voltage rating of the LC1D power contacts ?

                            Issue:
                            Identifying maximum voltage of an LC1D contactor

                            Product Line:
                            TeSys D Contactors

                            Environment:
                            IEC contactors and starters used in North America

                            Cause:
                            n/a

                            Resolution:
                            IThe maximum voltage per UL and CSA is 600VAC. 
                             

                            Are the D-Line contactors rated to break DC voltages?

                            Issue: 
                            Can the TeSys D line be used to control DC loads? 

                            Product Line:
                            Tesys D contactors

                            Environment:
                            Products sold and used in the United States
                             
                            Cause:
                             DC power circuit
                             
                            Resolution:
                             
                            Yes, 75 VDC (125 VDC for D115 & D150) per pole which means that through a four pole device breaking 300 VDC is possible by wiring all four power poles in series. However, be aware that the device current ratings will differ according to the number of poles in series and the type of application.

                            Devices are suitable but not UL Listed for DC applications.

                            More information on their DC ratings can be found in the current TeSys Motor Control and Protection Compentns catalog: https://www.schneider-electric.us/en/download/document/MKTED210011EN/


                             

                            Video: What auxiliary contact modules are available for the LC1D and LC2D contactors?

                            Issue:
                            Auxiliary contact modules for the LC1D and LC2D contactors

                            Product Line: 
                            Contactor and Starters - IEC

                            Environment:
                            North American Products

                            Resolution:
                            Select based on application requirements. Please note that the TeSys and Pre-TeSys auxiliary blocks are backward/forward compatible.
                            Front Mounting; maximum of 1 block per contactor:

                            N.O.-------N.C.-----TeSys P/N--------Pre-TeSys P/N
                            --1-----------1---------LADN11-----------LA1DN11
                            --1-----------1---------LADN11G---------LA1DN11G (See Footnote 1)
                            --1-----------1---------LADN11P---------LA1DN11P (See Footnote 1)
                            --2-----------0---------LADN20-----------LA1DN20
                            --2-----------0---------LA1DX20---------LA1DX20 (See Footnote 2)
                            --2-----------0---------LA1DY20---------LA1DY20 (See Footnote 3)
                            --0-----------2---------LADN02-----------LA1DN02
                            --2-----------2---------LADN22-----------LA1DN22
                            --2-----------2---------LADN22G---------LA1DN22G (See Footnote 1)
                            --2-----------2---------LADN22P---------LA1DN22P (See Footnote 1)
                            --2-----------2---------LADC22------------LA1DC22 (See Footnote 4)
                            --3-----------1---------LADN31------------LA1DN31
                            --3-----------1---------LA1DZ31----------LA1DZ31 (See Footnote 5)
                            --1-----------3---------LADN13------------LA1DN13
                            --4-----------0---------LADN40------------LA1DN40
                            --4-----------0---------LA1DZ40-----------LA1DZ40 (See Footnote 6)
                            --0-----------4---------LADN04------------LA1DN04




                            Front Mounting; maximum of 1 block per contactor: For use with D2 Series 25 amp through 80 amp contactors and TeSys Series 40 amp through 80 amp only.

                            N.O.-------N.C.-----TeSys P/N--------Pre-TeSys P/N
                            --1-----------0--------LADN10----------LA1DN10
                            --0-----------1--------LADN01----------LA1DN01

                            Side Mounting; maximum of 1 block on each side for D2 Series and Tesys Series 40 through 80 amp contactors. Tesys 9 through 32, 115, and 150 amps contactors will accept 1 block and is limited to left side only. (*) DC control devices will not accept side mount auxiliaries.
                            (*) DC control exceptions that will accept one left side mounted auxiliary: LC1D115 & LC1D150.

                            N.O.-------N.C.-----TeSys P/N--------Pre-TeSys P/N
                            --1-----------1--------LAD8N11----------LA8DN11
                            --2-----------0--------LAD8N20----------LA8DN20
                            --0-----------2--------LAD8N02----------N/A

                            Footnotes:
                            {1} EN50 012 Machine Tool Terminal Markings
                            {2} (2) NO Sealed Dust Tight Contacts
                            {3} Gold Flash Contacts
                            {4} (1) NO & (1) NC Standard and (1) NO & (1) NC Make Before Break
                            {5} (2) NO Dust Tight Contacts & (1) NO & (1) NC Standard Contacts
                            {6} (2) NO Dust Tight Contacts & (2) NO Standard Contacts

                            What is the color scheme of the Tesys D-Line contactors?

                            Issue:
                            Looking for different color scheme of the Tesys D-Line contactors.

                            Product Line:
                            Tesys D Contactors

                            Environment:
                            LC1D contactors

                            Resolution:
                            Beige and dark gray.
                             

                            What are the stand alone short circuit current ratings on the LC1D** contactors?

                            Issue:
                            Tesys D SCCR

                            Product Line:
                            Contactors and Overload Relays

                            Environment:
                            TeSys™ D Contactors and Overload Relays
                             
                            Resolution:
                            The contactors have a stand alone withstand rating that has been established by UL and is based on the maximum horsepower rating for a given device. However, only combination type starters are supplied with short circuit protective devices having a short circuit current rating.

                            They are as follows:
                            Horsepower SCCR (A)

                            0 thru 1 1,000
                            1 thru 50 5,000
                            51 thru 200 10,000
                            201 thru 400 18,000
                            401 thru 600 30,000
                            601 thru 900 42,000
                            901 thru 1600 85,000
                            1601+ 100,000

                            What is the replacement AC coil for LC1D/LC2D40, D50, D65, D80, and D95?

                            Issue:
                            AC Coil information for LC1D/LC2D40, D50, D65, D80, and D95

                            Product Line:
                            Tesys D Replacement Parts

                            Environment:
                            TeSys™ D AC Coils

                            Resolution:

                            Will the LAD** time delay auxiliary contact module fit the D2 series pre-Tesys contactors?

                            Issue:
                            Can new accessories be used on older style contactors

                            Product Line:
                            IEC contactors and starters

                            Environment:
                            Products sold and used in the United States

                            Cause:
                            Identifying product compatibility

                            Resolution:
                            Yes, all front mount D2 and Tesys series auxiliary modules are backward forward compatible.


                             

                            What is the part cod for a contactor 4P 2N/C 2N/O 48Vac coil

                             The part code is LC1D40008E7

                            What is the replacement contactor for the LC1D65004F5?

                            The new code is LC1DT80AF7 which is made to order.

                            What is the replacement for LC1D40004N5 Contactor?

                            What is the part number for the contactor that replaces the LC1D50E5?

                            The part number for the contactor that replaces the LC1D50E5 is - LC1D50AE7

                            For further information , visit link below:-
                            https://www.schneider-electric.com.au/en/search/LC1D50AE7
                             
                            Show More