Quantcast

TeSys D Contactor-3 Pole AC3 <= 440v="" 40a,="" 24v="" dc="">

TeSys D Contactor-3 Pole AC3 <= 440v="" 40a,="" 24v="" dc="">

TeSys D Contactor-3 Pole AC3 <= 440v="" 40a,="" 24v="" dc="">

Item Number: LC1D40ABBE

Product Dimensions

Width icon

Width55 mm

Height icon

Height122 mm

Depth icon

Depth120 mm

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Sustainable offer status

Green Premium product

Warranty

18 months

Range of product

  • TeSys D
  • TeSys Deca

Range

  • TeSys
  • TeSys Deca

Product or component type

contactor

Physical

Insulation resistance

> 10 MOhm for signalling circuit

IP degree of protection

IP20 front face conforming to IEC 60529

Climatic withstand

  • conforming to IACS E10
  • conforming to IEC 60947-1 Annex Q category D

Ambient air temperature for storage

-60...80 °C

Ambient air temperature for operation

  • -40...60 °C
  • 60...70 °C with derating

Height

122 mm

Width

55 mm

Depth

120 mm

Net weight

0.992 kg

REACh Regulation

Reference contains Substances of Very High Concern above the threshold

EU RoHS Directive

Compliant

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

Product out of China RoHS scope. Substance declaration for your information

Environmental Disclosure

ENVPEP1607010EN

Circularity Profile

ENVEOLI1607010EN

[Ue] rated operational voltage

power circuit: <= 690="" v="" ac="" 25...400="">

[Ie] rated operational current

  • 60 A (at <60 °c)="" at=""><= 440="" v="" ac-1="" for="" power="">
  • 40 A (at <60 °c)="" at=""><= 440="" v="" ac-3="" for="" power="">
  • 40 A (at <60 °c)="" at=""><= 440="" v="" ac-3e="" for="" power="">

Electrical durability

  • 2 Mcycles 35 A AC-3 at Ue <= 440="">
  • 0.7 Mcycles 60 A AC-1 at Ue <= 440="">
  • 2 Mcycles 35 A AC-3e at Ue <= 440="">

Mounting support

  • plate
  • rail

Standards

  • EN/IEC 60947-4-1
  • EN/IEC 60947-5-1
  • UL 60947-4-1
  • CSA C22.2 No 60947-4-1
  • IEC 60335-1

Product certifications

  • CCC
  • CSA
  • EAC
  • UL
  • KC
  • DNV-GL
  • LROS (Lloyds register of shipping)
  • UKCA

Connections - terminals

  • power circuit: EverLink BTR screw connectors 1 cable(s) 1-35 mm²solid
  • power circuit: EverLink BTR screw connectors 2 cable(s) 1-25 mm²solid
  • power circuit: EverLink BTR screw connectors 1 cable(s) 1-35 mm²flexible without cable end
  • power circuit: EverLink BTR screw connectors 2 cable(s) 1-25 mm²flexible without cable end
  • power circuit: EverLink BTR screw connectors 1 cable(s) 1-35 mm²flexible with cable end
  • power circuit: EverLink BTR screw connectors 2 cable(s) 1-25 mm²flexible with cable end
  • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²solid
  • control circuit: screw clamp terminals 2 cable(s) 1-4 mm²solid
  • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible with cable end
  • control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end
  • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end
  • control circuit: screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end

Mechanical durability

6 Mcycles

Others

Coil technology

built-in bidirectional peak limiting

Control circuit voltage limits

  • <= 0.1="" uc="" (-40-70="" °c):drop-out="">
  • 0.8...1.2 Uc (-40-60 °C):operational DC
  • 1...1.2 Uc (60-70 °C):operational DC

Inrush power in W

11 W at 20 °C

Hold-in power consumption in W

0.5...0.5 W at 20 °C

Heat dissipation

0.5...0.5 W

Auxiliary contacts type

  • type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
  • type mirror contact 1 NC conforming to IEC 60947-4-1

Signalling circuit frequency

25...400 Hz

Minimum switching current

5 mA for signalling circuit

Minimum switching voltage

17 V for signalling circuit

Non-overlap time

  • 1.5 ms on de-energisation between NC and NO contact
  • 1.5 ms on energisation between NC and NO contact

Compatibility code

LC1D

Pollution degree

3

Operating altitude

0...3000 m

Fire resistance

850 °C conforming to IEC 60695-2-1

Flame retardance

V1 conforming to UL 94

Mechanical robustness

  • vibrations contactor open: 2 Gn, 5...300 Hz
  • vibrations contactor closed: 4 Gn, 5...300 Hz
  • shocks contactor open: 10 Gn for 11 ms
  • shocks contactor closed: 15 Gn for 11 ms

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Weight

1.06 kg

Package 1 Height

6.2 cm

Package 1 width

13.6 cm

Package 1 Length

15.2 cm

Unit Type of Package 2

S02

Number of Units in Package 2

9

Package 2 Weight

9.823 kg

Package 2 Height

15 cm

Package 2 width

30 cm

Package 2 Length

40 cm

WEEE

The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

Halogen content performance

Halogen free plastic parts & cables product

Product name

  • TeSys D Green
  • TeSys Deca

Device short name

LC1D

Contactor application

  • motor control
  • resistive load

Utilisation category

  • AC-1
  • AC-3
  • AC-3e

Poles description

3P

Pole contact composition

3 NO

Motor power kW

  • 11 kW at 220...230 V AC 50 Hz (AC-3)
  • 18.5 kW at 380...400 V AC 50 Hz (AC-3)
  • 22 kW at 415 V AC 50 Hz (AC-3)
  • 22 kW at 440 V AC 50 Hz (AC-3)
  • 22 kW at 500 V AC 50 Hz (AC-3)
  • 30 kW at 660...690 V AC 50 Hz (AC-3)
  • 11 kW at 220...230 V AC 50 Hz (AC-3e)
  • 18.5 kW at 380...400 V AC 50 Hz (AC-3e)
  • 22 kW at 415 V AC 50 Hz (AC-3e)
  • 22 kW at 440 V AC 50 Hz (AC-3e)
  • 22 kW at 500 V AC 50 Hz (AC-3e)
  • 30 kW at 660...690 V AC 50 Hz (AC-3e)

Motor power hp

  • 3 hp at 115 V AC 60 Hz for 1 phase motors
  • 5 hp at 230/240 V AC 60 Hz for 1 phase motors
  • 10 hp at 200/208 V AC 60 Hz for 3 phases motors
  • 10 hp at 230/240 V AC 60 Hz for 3 phases motors
  • 30 hp at 460/480 V AC 60 Hz for 3 phases motors
  • 30 hp at 575/600 V AC 60 Hz for 3 phases motors

Control circuit type

DC DC low consumption

[Uc] control circuit voltage

24 V DC

Coil type

DC low consumption

Auxiliary contact composition

1 NO + 1 NC

[Uimp] rated impulse withstand voltage

6 kV conforming to IEC 60947

Overvoltage category

III

[Ith] conventional free air thermal current

  • 60 A (at 60 °C) for power circuit
  • 10 A (at 60 °C) for signalling circuit

Irms rated making capacity

  • 800 A at 440 V for power circuit conforming to IEC 60947
  • 140 A AC for signalling circuit conforming to IEC 60947-5-1
  • 250 A DC for signalling circuit conforming to IEC 60947-5-1

Rated breaking capacity

800 A at 440 V for power circuit conforming to IEC 60947

[Icw] rated short-time withstand current

  • 72 A 40 °C - 10 min for power circuit
  • 165 A 40 °C - 1 min for power circuit
  • 320 A 40 °C - 10 s for power circuit
  • 720 A 40 °C - 1 s for power circuit
  • 100 A - 1 s for signalling circuit
  • 120 A - 500 ms for signalling circuit
  • 140 A - 100 ms for signalling circuit

Associated fuse rating

  • 80 A gG at <= 690="" v="" coordination="" type="" 1="" for="" power="">
  • 80 A gG at <= 690="" v="" coordination="" type="" 2="" for="" power="">
  • 10 A gG for signalling circuit conforming to IEC 60947-5-1

Average impedance

1.5 mOhm - Ith 60 A 50 Hz for power circuit

[Ui] rated insulation voltage

  • power circuit: 690 V conforming to IEC 60947-4-1
  • signalling circuit: 690 V conforming to IEC 60947-1

Power dissipation per pole

  • 5.4 W AC-1
  • 2.4 W AC-3
  • 2.4 W AC-3e

Protective cover

with

Tightening torque

  • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
  • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
  • power circuit: 8 N.m - on EverLink BTR screw connectors - cable 25-35 mm² hexagonal screw head 4 mm
  • power circuit: 5 N.m - on EverLink BTR screw connectors - cable 1-25 mm² hexagonal screw head 4 mm
  • power circuit: 5 N.m - with screwdriver pozidriv No 2
  • control circuit: 1.7 N.m - with screwdriver pozidriv No 2

Operating time

  • 55...65 ms closing
  • 20...120 ms opening (date code >= 17221)
  • 20...80 ms opening (date code >= 18011)

Safety reliability level

  • B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
  • B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1

Maximum operating rate

3600 cyc/h 60 °C
Show all specifications

Documents & downloads

hide show
Filter items
  • All

  • CAD Files and Packs

  • Product Brochures

  • Technical Data Catalogues

  • Installation Instruction

  • Data Bulletin

  • Product Environmental

  • End of Life Manual

  • Certificates (MSDS)

  • Declaration of Conformity