TeSys LC1D4000 contactor, 4 poles, screw clamp terminals or lugs, without cover, 60A

TeSys D Contactor, 4P(2 NO + 2 NC), AC-1, <= 440V, 60A, 415VAC, 50/60 Hz Coil

Catalogue Number: LC1D40008N7
TeSys LC1D4000 contactor, 4 poles, screw clamp terminals or lugs, without cover, 60A
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Range of product
TeSys D
Range
TeSys
Product name
TeSys D
Product or component type
contactor
Device short name
LC1D
Contactor application
resistive load
Utilisation category
AC-1
Poles description
4P
Pole contact composition
2 NO + 2 NC
[Ue] rated operational voltage
  • power circuit: <= 690 V AC 25...400 Hz
  • power circuit: <= 300 V DC
    • [Ie] rated operational current
      60 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
      Control circuit type
      AC at 50/60 Hz
      [Uc] control circuit voltage
      415 V AC 50/60 Hz
      [Uimp] rated impulse withstand voltage
      6 kV conforming to IEC 60947
      Overvoltage category
      III
      [Ith] conventional free air thermal current
      60 A (at 60 °C) for power circuit
      Irms rated making capacity
      800 A at 440 V for power circuit conforming to IEC 60947
      Rated breaking capacity
      800 A at 440 V for power circuit conforming to IEC 60947
      [Icw] rated short-time withstand current
    • 320 A 40 °C - 10 s for power circuit
    • 720 A 40 °C - 1 s for power circuit
    • 72 A 40 °C - 10 min for power circuit
    • 165 A 40 °C - 1 min for power circuit
      • Associated fuse rating
      • 80 A gG at <= 690 V coordination type 1 for power circuit
      • 80 A gG at <= 690 V coordination type 2 for power circuit
        • Average impedance
          1.5 mOhm - Ith 60 A 50 Hz for power circuit
          [Ui] rated insulation voltage
        • power circuit: 600 V CSA certified
        • power circuit: 600 V UL certified
        • power circuit: 690 V conforming to IEC 60947-4-1
          • Electrical durability
            1.4 Mcycles 60 A AC-1 at Ue <= 440 V
            Power dissipation per pole
            5.4 W AC-1
            Protective cover
            without
            Mounting support
          • plate
          • rail
            • Standards
            • CSA C22.2 No 14
            • EN 60947-4-1
            • EN 60947-5-1
            • IEC 60947-4-1
            • IEC 60947-5-1
            • UL 508
              • Product certifications
              • GOST
              • UL
              • LROS (Lloyds register of shipping)
              • CSA
              • RINA
              • DNV
              • BV
              • GL
              • CCC
                • Connections - terminals
                • control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end
                • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end
                • control circuit: screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end
                • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible with cable end
                • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²solid without cable end
                • control circuit: screw clamp terminals 2 cable(s) 1-4 mm²solid without cable end
                • power circuit: screw clamp terminals 1 cable(s) 1-35 mm²flexible without cable end
                • power circuit: screw clamp terminals 2 cable(s) 1-25 mm²flexible without cable end
                • power circuit: screw clamp terminals 1 cable(s) 1-35 mm²flexible with cable end
                • power circuit: screw clamp terminals 2 cable(s) 1-25 mm²flexible with cable end
                • power circuit: screw clamp terminals 1 cable(s) 1-35 mm²solid without cable end
                • power circuit: screw clamp terminals 2 cable(s) 1-25 mm²solid without cable end
                  • Tightening torque
                  • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
                  • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
                  • power circuit: 8 N.m - on screw clamp terminals - cable 25-35 mm² hexagonal screw head 4 mm
                  • power circuit: 5 N.m - on screw clamp terminals - cable 1-25 mm² hexagonal screw head 4 mm
                    • Operating time
                    • 4...19 ms opening
                    • 12...26 ms closing
                      • Safety reliability level
                      • B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
                      • B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
                        • Mechanical durability
                          6 Mcycles
                          Maximum operating rate
                          3600 cyc/h 60 °C
                          Coil technology
                          without built-in suppressor module
                          Control circuit voltage limits
                        • drop-out: 0.3...0.6 Uc AC 50/60 Hz (at 60 °C)
                        • operational: 0.8...1.1 Uc AC 50 Hz (at 60 °C)
                        • operational: 0.85...1.1 Uc AC 60 Hz (at 60 °C)
                          • Inrush power in VA
                          • 140-140 VA 60 Hz cos phi 0.75 (at 20 °C)
                          • 160-160 VA 50 Hz cos phi 0.75 (at 20 °C)
                            • Hold-in power consumption in VA
                            • 13-13 VA 60 Hz cos phi 0.3 (at 20 °C)
                            • 15-15 VA 50 Hz cos phi 0.3 (at 20 °C)
                              • Heat dissipation
                                4-5 W at 50/60 Hz
                                Contact compatibility
                                M1
                                Compatibility code
                                LC1D
                                IP degree of protection
                                IP20 front face conforming to IEC 60529
                                Protective treatment
                                TH conforming to IEC 60068-2-30
                                Pollution degree
                                3
                                Ambient air temperature for operation
                                -5-60 °C
                                Ambient air temperature for storage
                                -60-80 °C
                                Permissible ambient air temperature around the device
                                -40-70 °C at Uc
                                Operating altitude
                                3000 m without
                                Fire resistance
                                850 °C conforming to IEC 60695-2-1
                                Flame retardance
                                V1 conforming to UL 94
                                Mechanical robustness
                              • vibrations contactor open: 2 Gn, 5...300 Hz
                              • vibrations contactor closed: 4 Gn, 5...300 Hz
                              • shocks contactor closed: 15 Gn for 11 ms
                              • shocks contactor open: 10 Gn for 11 ms
                                • Height
                                  127 mm
                                  Width
                                  85 mm
                                  Depth
                                  125 mm
                                  Net weight
                                  1.44 kg
                                  Sustainable offer status
                                  Green Premium product
                                  REACh Regulation
                                  Free of Substances of Very High Concern above the threshold
                                  REACh free of SVHC
                                  Yes
                                  EU RoHS Directive
                                  Compliant
                                  Toxic heavy metal free
                                  Yes
                                  Mercury free
                                  Yes
                                  RoHS exemption information
                                  Yes
                                  China RoHS Regulation
                                  X
                                  Environmental Disclosure
                                  ENVPEP1503009EN
                                  Circularity Profile
                                  ENVEOLI1503009EN
                                  WEEE
                                  The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                                  Warranty
                                  18 months

                                  Documents & downloads

                                  hide show
                                  Filter items
                                  • All

                                  • Product Brochures

                                  • Technical Data Catalogues

                                  • Product Environmental

                                  • End of Life Manual

                                  • Certificates (MSDS)

                                  • Declaration of Conformity

                                  Frequently Asked Questions

                                  hide show

                                  What is the power terminal lug data for the LC1D40, LC1D50, LC1D65, LP1D40, LP1D50, and LP1D65 contactor?

                                  Issue:
                                  Identifying power terminal lug data for the D2 style contactors

                                  Product Line:
                                  Tesys D line contactors

                                  Environment:
                                  Products sold and used in the United States

                                  Cause:
                                  Power terminal lug data required

                                  Resolution:
                                  For contactors with screw clamp terminals:
                                  stranded cable w/o cable end : One #10-3 AWG or Two #10-4 AWG per terminal.
                                  stranded cable w/cable end: One #10-4 AWG or Two #12-2 AWG per terminal.
                                  solid cable: One #10-3 AWG or Two #10-6 AWG per terminal.

                                  What is the maximum UL/CSA AC voltage rating of the LC1D power contacts ?

                                  Issue:
                                  Identifying maximum voltage of an LC1D contactor

                                  Product Line:
                                  TeSys D Contactors

                                  Environment:
                                  IEC contactors and starters used in North America

                                  Cause:
                                  n/a

                                  Resolution:
                                  IThe maximum voltage per UL and CSA is 600VAC. 
                                   

                                  What is the color scheme of the Tesys D-Line contactors?

                                  Issue:
                                  Looking for different color scheme of the Tesys D-Line contactors.

                                  Product Line:
                                  Tesys D Contactors

                                  Environment:
                                  LC1D contactors

                                  Resolution:
                                  Beige and dark gray.
                                   

                                  Are the D-Line contactors rated to break DC voltages?

                                  Issue: 
                                  Can the TeSys D line be used to control DC loads? 

                                  Product Line:
                                  Tesys D contactors

                                  Environment:
                                  Products sold and used in the United States
                                   
                                  Cause:
                                   DC power circuit
                                   
                                  Resolution:
                                   
                                  Yes, 75 VDC (125 VDC for D115 & D150) per pole which means that through a four pole device breaking 300 VDC is possible by wiring all four power poles in series. However, be aware that the device current ratings will differ according to the number of poles in series and the type of application.

                                  Devices are suitable but not UL Listed for DC applications.

                                  More information on their DC ratings can be found in the current TeSys Motor Control and Protection Compentns catalog: https://www.schneider-electric.us/en/download/document/MKTED210011EN/


                                   

                                  What are the stand alone short circuit current ratings on the LC1D** contactors?

                                  Issue:
                                  Tesys D SCCR

                                  Product Line:
                                  Contactors and Overload Relays

                                  Environment:
                                  TeSys™ D Contactors and Overload Relays
                                   
                                  Resolution:
                                  The contactors have a stand alone withstand rating that has been established by UL and is based on the maximum horsepower rating for a given device. However, only combination type starters are supplied with short circuit protective devices having a short circuit current rating.

                                  They are as follows:
                                  Horsepower SCCR (A)

                                  0 thru 1 1,000
                                  1 thru 50 5,000
                                  51 thru 200 10,000
                                  201 thru 400 18,000
                                  401 thru 600 30,000
                                  601 thru 900 42,000
                                  901 thru 1600 85,000
                                  1601+ 100,000

                                  Video: What auxiliary contact modules are available for the LC1D and LC2D contactors?

                                  Issue:
                                  Auxiliary contact modules for the LC1D and LC2D contactors

                                  Product Line: 
                                  Contactor and Starters - IEC

                                  Environment:
                                  North American Products

                                  Resolution:
                                  Select based on application requirements. Please note that the TeSys and Pre-TeSys auxiliary blocks are backward/forward compatible.
                                  Front Mounting; maximum of 1 block per contactor:

                                  N.O.-------N.C.-----TeSys P/N--------Pre-TeSys P/N
                                  --1-----------1---------LADN11-----------LA1DN11
                                  --1-----------1---------LADN11G---------LA1DN11G (See Footnote 1)
                                  --1-----------1---------LADN11P---------LA1DN11P (See Footnote 1)
                                  --2-----------0---------LADN20-----------LA1DN20
                                  --2-----------0---------LA1DX20---------LA1DX20 (See Footnote 2)
                                  --2-----------0---------LA1DY20---------LA1DY20 (See Footnote 3)
                                  --0-----------2---------LADN02-----------LA1DN02
                                  --2-----------2---------LADN22-----------LA1DN22
                                  --2-----------2---------LADN22G---------LA1DN22G (See Footnote 1)
                                  --2-----------2---------LADN22P---------LA1DN22P (See Footnote 1)
                                  --2-----------2---------LADC22------------LA1DC22 (See Footnote 4)
                                  --3-----------1---------LADN31------------LA1DN31
                                  --3-----------1---------LA1DZ31----------LA1DZ31 (See Footnote 5)
                                  --1-----------3---------LADN13------------LA1DN13
                                  --4-----------0---------LADN40------------LA1DN40
                                  --4-----------0---------LA1DZ40-----------LA1DZ40 (See Footnote 6)
                                  --0-----------4---------LADN04------------LA1DN04




                                  Front Mounting; maximum of 1 block per contactor: For use with D2 Series 25 amp through 80 amp contactors and TeSys Series 40 amp through 80 amp only.

                                  N.O.-------N.C.-----TeSys P/N--------Pre-TeSys P/N
                                  --1-----------0--------LADN10----------LA1DN10
                                  --0-----------1--------LADN01----------LA1DN01

                                  Side Mounting; maximum of 1 block on each side for D2 Series and Tesys Series 40 through 80 amp contactors. Tesys 9 through 32, 115, and 150 amps contactors will accept 1 block and is limited to left side only. (*) DC control devices will not accept side mount auxiliaries.
                                  (*) DC control exceptions that will accept one left side mounted auxiliary: LC1D115 & LC1D150.

                                  N.O.-------N.C.-----TeSys P/N--------Pre-TeSys P/N
                                  --1-----------1--------LAD8N11----------LA8DN11
                                  --2-----------0--------LAD8N20----------LA8DN20
                                  --0-----------2--------LAD8N02----------N/A

                                  Footnotes:
                                  {1} EN50 012 Machine Tool Terminal Markings
                                  {2} (2) NO Sealed Dust Tight Contacts
                                  {3} Gold Flash Contacts
                                  {4} (1) NO & (1) NC Standard and (1) NO & (1) NC Make Before Break
                                  {5} (2) NO Dust Tight Contacts & (1) NO & (1) NC Standard Contacts
                                  {6} (2) NO Dust Tight Contacts & (2) NO Standard Contacts

                                  What is the part cod for a contactor 4P 2N/C 2N/O 48Vac coil

                                   The part code is LC1D40008E7

                                  What is the replacement AC coil for LC1D/LC2D40, D50, D65, D80, and D95?

                                  Issue:
                                  AC Coil information for LC1D/LC2D40, D50, D65, D80, and D95

                                  Product Line:
                                  Tesys D Replacement Parts

                                  Environment:
                                  TeSys™ D AC Coils

                                  Resolution:

                                  What is the replacement for LC1D40004N5 Contactor?

                                  What is the dimensions for a LC1K09008N7

                                   Dimensions 45mm(W) x 50mm(H) x 57mm(D).

                                  Will the LAD** time delay auxiliary contact module fit the D2 series pre-Tesys contactors?

                                  Issue:
                                  Can new accessories be used on older style contactors

                                  Product Line:
                                  IEC contactors and starters

                                  Environment:
                                  Products sold and used in the United States

                                  Cause:
                                  Identifying product compatibility

                                  Resolution:
                                  Yes, all front mount D2 and Tesys series auxiliary modules are backward forward compatible.


                                   

                                  The LC1D4011N7 is a discontinued part - what is the alternative?

                                  LC1D4011N7
                                  Reason for substitution:  end of life
                                  Substitution date:  30/12/2009
                                   
                                  This product is replaced by:
                                  LC1D40AN7   -   TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 40 A - 415 V AC 50/60 Hz coil
                                  Show More