Quantcast

TeSys D Contactor, 3P(3 NO), AC-3, <= 440V, 38A, 42VAC, 50/60 Hz Coil

TeSys D Contactor, 3P(3 NO), AC-3, <= 440V, 38A, 42VAC, 50/60 Hz Coil

TeSys D Contactor, 3P(3 NO), AC-3, <= 440V, 38A, 42VAC, 50/60 Hz Coil

Item Number: LC1D38D7

Retail
$816.59
RRP (Inc. GST)

Product Dimensions

Width icon

Width45 mm

Height icon

Height85 mm

Depth icon

Depth92 mm

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

TeSys D

Range

TeSys

Product or component type

contactor

Sustainable offer status

Green Premium product

Warranty

18 months

Physical

[Ue] rated operational voltage

  • power circuit: <= 690 V AC 25...400 Hz
  • power circuit: <= 300 V DC
    • [Ie] rated operational current

    • 50 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
    • 38 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
      • Electrical durability

      • 1.4 Mcycles 50 A AC-1 at Ue <= 440 V
      • 1.4 Mcycles 38 A AC-3 at Ue <= 440 V
        • Mounting support

        • rail
        • plate
          • Standards

          • CSA C22.2 No 14
          • EN 60947-4-1
          • EN 60947-5-1
          • IEC 60947-4-1
          • IEC 60947-5-1
          • UL 508
            • Product certifications

            • DNV
            • LROS (Lloyds register of shipping)
            • GOST
            • RINA
            • CCC
            • CSA
            • GL
            • BV
            • UL
              • Connections - terminals

              • control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end
              • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end
              • control circuit: screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end
              • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible with cable end
              • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²solid without cable end
              • control circuit: screw clamp terminals 2 cable(s) 1-4 mm²solid without cable end
              • power circuit: screw clamp terminals 1 cable(s) 2.5-10 mm²flexible without cable end
              • power circuit: screw clamp terminals 2 cable(s) 2.5-10 mm²flexible without cable end
              • power circuit: screw clamp terminals 1 cable(s) 1-10 mm²flexible with cable end
              • power circuit: screw clamp terminals 2 cable(s) 1.5-6 mm²flexible with cable end
              • power circuit: screw clamp terminals 1 cable(s) 1.5-10 mm²solid without cable end
              • power circuit: screw clamp terminals 2 cable(s) 2.5-10 mm²solid without cable end
                • Mechanical durability

                  15 Mcycles

                  Insulation resistance

                  > 10 MOhm for signalling circuit

                  IP degree of protection

                  IP20 front face conforming to IEC 60529

                  Ambient air temperature for operation

                • -40-60 °C
                • 60-70 °C with derating
                  • Ambient air temperature for storage

                    -60-80 °C

                    Height

                    85 mm

                    Width

                    45 mm

                    Depth

                    92 mm

                    Net weight

                    0.38 kg

                    REACh Regulation

                    Free of Substances of Very High Concern above the threshold

                    REACh free of SVHC

                    Yes

                    EU RoHS Directive

                    Compliant

                    Toxic heavy metal free

                    Yes

                    Mercury free

                    Yes

                    RoHS exemption information

                    Yes

                    China RoHS Regulation

                     Pro-active China RoHS declaration (out of China RoHS legal scope)

                    Environmental Disclosure

                    ENVPEP110229EN

                    Circularity Profile

                    ENVEOLI1102029EN

                    Others

                    Product name

                    TeSys D

                    Device short name

                    LC1D

                    Device short name

                    LC1D38

                    Contactor application

                  • motor control
                  • resistive load
                    • Utilisation category

                    • AC-3
                    • AC-4
                    • AC-1
                      • Poles description

                        3P

                        Pole contact composition

                        3 NO

                        Motor power kW

                      • 18.5 kW at 500 V AC 50/60 Hz (AC-3)
                      • 18.5 kW at 660...690 V AC 50/60 Hz (AC-3)
                      • 7.5 kW at 400 V AC 50/60 Hz (AC-4)
                      • 18.5 kW at 380...400 V AC 50/60 Hz (AC-3)
                      • 9 kW at 220...230 V AC 50/60 Hz (AC-3)
                      • 18.5 kW at 415...440 V AC 50/60 Hz (AC-3)
                        • Motor power hp

                        • 10 hp at 230/240 V AC 50/60 Hz for 3 phases motors
                        • 10 hp at 200/208 V AC 50/60 Hz for 3 phases motors
                        • 5 hp at 240 V AC 50/60 Hz for 1 phase motors
                        • 20 hp at 480 V AC 50/60 Hz for 3 phases motors
                        • 25 hp at 600 V AC 50/60 Hz for 3 phases motors
                          • Control circuit type

                            AC at 50/60 Hz

                            [Uc] control circuit voltage

                            42 V AC 50/60 Hz

                            Auxiliary contact composition

                            1 NO + 1 NC

                            [Uimp] rated impulse withstand voltage

                            6 kV conforming to IEC 60947

                            Overvoltage category

                            III

                            [Ith] conventional free air thermal current

                          • 10 A (at 60 °C) for signalling circuit
                          • 50 A (at 60 °C) for power circuit
                            • Irms rated making capacity

                            • 140 A AC for signalling circuit conforming to IEC 60947-5-1
                            • 250 A DC for signalling circuit conforming to IEC 60947-5-1
                            • 550 A at 440 V for power circuit conforming to IEC 60947
                              • Rated breaking capacity

                                550 A at 440 V for power circuit conforming to IEC 60947

                                [Icw] rated short-time withstand current

                              • 60 A 40 °C - 10 min for power circuit
                              • 430 A 40 °C - 1 s for power circuit
                              • 150 A 40 °C - 1 min for power circuit
                              • 310 A 40 °C - 10 s for power circuit
                              • 100 A - 1 s for signalling circuit
                              • 120 A - 500 ms for signalling circuit
                              • 140 A - 100 ms for signalling circuit
                                • Associated fuse rating

                                • 10 A gG for signalling circuit conforming to IEC 60947-5-1
                                • 63 A gG at <= 690 V coordination type 1 for power circuit
                                • 63 A gG at <= 690 V coordination type 2 for power circuit
                                  • Average impedance

                                    2 mOhm - Ith 50 A 50 Hz for power circuit

                                    [Ui] rated insulation voltage

                                  • power circuit: 600 V CSA certified
                                  • power circuit: 600 V UL certified
                                  • signalling circuit: 690 V conforming to IEC 60947-1
                                  • signalling circuit: 600 V CSA certified
                                  • signalling circuit: 600 V UL certified
                                  • power circuit: 690 V conforming to IEC 60947-4-1
                                    • Power dissipation per pole

                                    • 5 W AC-1
                                    • 3 W AC-3
                                      • Protective cover

                                        with

                                        Tightening torque

                                      • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
                                      • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
                                      • power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
                                      • power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver Philips No 2
                                        • Operating time

                                        • 4...19 ms opening
                                        • 12...22 ms closing
                                          • Safety reliability level

                                          • B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
                                          • B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
                                            • Maximum operating rate

                                              3600 cyc/h 60 °C

                                              Coil technology

                                              without built-in suppressor module

                                              Control circuit voltage limits

                                            • 0.3...0.6 Uc (-40-70 °C):drop-out AC 50/60 Hz
                                            • 0.8...1.1 Uc (-40-60 °C):operational AC 50 Hz
                                            • 0.85...1.1 Uc (-40-60 °C):operational AC 60 Hz
                                            • 1...1.1 Uc (60-70 °C):operational AC 50/60 Hz
                                              • Inrush power in VA

                                              • 70-70 VA 60 Hz cos phi 0.75 (at 20 °C)
                                              • 70-70 VA 50 Hz cos phi 0.75 (at 20 °C)
                                                • Hold-in power consumption in VA

                                                • 7.5-7.5 VA 60 Hz cos phi 0.3 (at 20 °C)
                                                • 7-7 VA 50 Hz cos phi 0.3 (at 20 °C)
                                                  • Heat dissipation

                                                    2-3 W at 50/60 Hz

                                                    Auxiliary contacts type

                                                  • type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
                                                  • type mirror contact 1 NC conforming to IEC 60947-4-1
                                                    • Signalling circuit frequency

                                                      25...400 Hz

                                                      Minimum switching current

                                                      5 mA for signalling circuit

                                                      Minimum switching voltage

                                                      17 V for signalling circuit

                                                      Non-overlap time

                                                    • 1.5 ms on de-energisation between NC and NO contact
                                                    • 1.5 ms on energisation between NC and NO contact
                                                      • Contact compatibility

                                                        M2

                                                        Compatibility code

                                                        LC1D

                                                        Power range

                                                      • 7-11 kW at 200-240 V 3 phases
                                                      • 15-25 kW at 380-440 V 3 phases
                                                      • 15-25 kW at 480-500 V 3 phases
                                                      • 15-25 kW at 525-690 V 3 phases
                                                      • 4-6 kW at 100-120 V 3 phases
                                                        • Motor starter type

                                                          direct on-line contactor

                                                          Protective treatment

                                                          TH conforming to IEC 60068-2-30

                                                          Pollution degree

                                                          3

                                                          Operating altitude

                                                          0...3000 m

                                                          Fire resistance

                                                          850 °C conforming to IEC 60695-2-1

                                                          Flame retardance

                                                          V1 conforming to UL 94

                                                          Mechanical robustness

                                                        • vibrations contactor open: 2 Gn, 5...300 Hz
                                                        • vibrations contactor closed: 4 Gn, 5...300 Hz
                                                        • shocks contactor closed: 15 Gn for 11 ms
                                                        • shocks contactor open: 8 Gn for 11 ms
                                                          • Unit Type of Package 1

                                                            PCE

                                                            Number of Units in Package 1

                                                            1

                                                            Package 1 Weight

                                                            422 g

                                                            Package 1 Height

                                                            5.6 cm

                                                            Package 1 width

                                                            11.8 cm

                                                            Package 1 Length

                                                            9.4 cm

                                                            Unit Type of Package 2

                                                            S02

                                                            Number of Units in Package 2

                                                            20

                                                            Package 2 Weight

                                                            8.73 kg

                                                            Package 2 Height

                                                            15 cm

                                                            Package 2 width

                                                            30 cm

                                                            Package 2 Length

                                                            40 cm

                                                            WEEE

                                                            The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

                                                            PVC free

                                                            Yes
                                                            Show all specifications

                                                            Documents & downloads

                                                            hide show
                                                            Filter items
                                                            • All

                                                            • CAD Files and Packs

                                                            • Product Brochures

                                                            • Technical Data Catalogues

                                                            • Installation Instruction

                                                            • End of Life Manual

                                                            • Product Environmental

                                                            • Certificates (MSDS)

                                                            • Declaration of Conformity

                                                            Frequently Asked Questions

                                                            hide show

                                                            What is the maximum UL/CSA AC voltage rating of the LC1D power contacts ?

                                                            Issue:
                                                            Identifying maximum voltage of an LC1D contactor

                                                            Product Line:
                                                            TeSys D Contactors

                                                            Environment:
                                                            IEC contactors and starters used in North America

                                                            Cause:
                                                            n/a

                                                            Resolution:
                                                            IThe maximum voltage per UL and CSA is 600VAC. 
                                                             

                                                            What is the coil tolerance for Tesys D-line contactors LC1D09 - LC1D38?

                                                            Issue:
                                                            LC1D09 - LC1D38 Coil tolerance

                                                            Product Line:
                                                            Contactors and Starters, IEC

                                                            Environment:
                                                            Tesys D Contactors

                                                            Cause:
                                                            Needs the coil tolerance for Tesys D-line contactors LC1D09 - LC1D38.

                                                            Resolution:
                                                            AC single frequency coils: 50Hz and 60 Hz (-20% / +10%);
                                                            AC dual frequency coils: 50Hz (-20% / +10%) ; 60Hz (-15% / +10%)
                                                            DC standard coil for LC1D09 -D38 and LC1DT20 to DT40: (-30% / +25%)
                                                            DC standard coil for LP1D12 and D25: (-20% / +10%)
                                                            DC wide range coil for LP1D12 and D25 : (-30% to +25%)

                                                            What is the power terminal lug data for the LC1D09, LC1DT20, LC1D12, and LC1DT25 contactor?

                                                            Issue:
                                                            Power terminal lug data required for the 9 and 12 amp rated Tesys D contactors

                                                            Product Line:
                                                            IEC Contactors and Starters

                                                            Environment:
                                                            Tesys D Contactors

                                                            Resolution:
                                                            For contactors with screw clamp terminals:
                                                            stranded cable w/o cable end : One or Two #18-10 AWG per terminal.
                                                            stranded cable w/cable end: One or Two #18-10 AWG per terminal.
                                                            solid cable: One or Two #18-8 AWG per terminal.

                                                            What is the power terminal lug data for the LC1D40, LC1D50, LC1D65, LP1D40, LP1D50, and LP1D65 contactor?

                                                            Issue:
                                                            Identifying power terminal lug data for the D2 style contactors

                                                            Product Line:
                                                            IEC Contactors and Starters

                                                            Environment:
                                                            Tesys D line contactors

                                                            Cause:
                                                            Power terminal lug data required

                                                            Resolution:
                                                            For contactors with screw clamp terminals:
                                                            stranded cable w/o cable end : One #10-3 AWG or Two #10-4 AWG per terminal.
                                                            stranded cable w/cable end: One #10-4 AWG or Two #12-2 AWG per terminal.
                                                            solid cable: One #10-3 AWG or Two #10-6 AWG per terminal.

                                                            What is the replacement coil part number for the LC*D09 through LC*D32 and LC*DT20 through LC*DT40 TeSys contactors?

                                                            Issue:
                                                            Identifying replacement coils for tesys D non-reversing and reversing conactors

                                                            Product Line:
                                                            IEC Contactors and Starters

                                                            Environment:
                                                            Products sold and used in the United States

                                                            Cause:
                                                            Replacement coil is needed

                                                            Resolution:
                                                            DC replacement coils are not available.
                                                            AC Coils are 50/60 hertz for voltages as listed below:

                                                            Volts - Part Number
                                                            12 ____ LXD1J7
                                                            21 ____ LXD1Z7
                                                            24 ____ LXD1B7
                                                            32 ____ LXD1C7
                                                            36 ____ LXD1CC7
                                                            42 ____ LXD1D7
                                                            48 ____ LXD1E7
                                                            60 ____ LXD1EE7
                                                            100 ___ LXD1K7 ( never brought to North America )
                                                            110 ___ LXD1F7
                                                            115 ___ LXD1FE7
                                                            120 ___ LXD1G7
                                                            127 ___ LXD1FC7
                                                            200 ___ LXD1L7
                                                            208 ___ LXD1LE7
                                                            220 ___ LXD1M7
                                                            230 ___ LXD1P7
                                                            240 ___ LXD1U7
                                                            277 ___ LXD1W7
                                                            380 ___ LXD1Q7
                                                            400 ___ LXD1V7
                                                            415 ___ LXD1N7
                                                            440 ___ LXD1R7
                                                            480 ___ LXD1T7
                                                            575 ___ LXD1SC7
                                                            600 ___ LXD1X7
                                                            690 ___ LXD1Y7


                                                            Note: A contactor with an AC coil can be changed to a different AC voltage coil, IE you can take an LC1D09 with a 120VAC coil and put a 24VAC coil in it instead. An AC device cannot be switched to a DC coil, and a DC device cannot be switches to an AC coil. 

                                                            What are the coil voltage codes for the LC1D09 / LC2D09 through LC1D38 / LC2D38 TeSys contactors?

                                                            Issue:
                                                            Coil Voltage suffixes for Tesys D contactors LC*D 09/38

                                                            Product Line:
                                                            IEC Contactors and Starters

                                                            Environment:
                                                            Tesys D contactors

                                                            Cause:
                                                            Selection

                                                            Resolution:
                                                            The following lists the more common voltage suffix codes for these product lines.  For a more comprehensive list and to determine compatibility with a given product, refer to the catalog below.

                                                            AC Volts ___Code     AC Volts ___Code
                                                            12 ___ J7                   208 ___ LE7
                                                            21 ___ Z7                   220 ___ M7
                                                            24 ___ B7                  230 ___ P7
                                                            32 ___ C7                  240 ___ U7
                                                            36 ___ CC7               277 ___ W7
                                                            42 ___ D7                  380 ___ Q7
                                                            48 ___ E7                   400 ___ V7
                                                            60 ___ EE7                415 ___ N7
                                                            100 ___ K7                440 ___ R7
                                                            110 ___ F7                480 ___ T7
                                                            115 ___ FE7              575 ___ SC7
                                                            120 ___ G7                600 ___ X7
                                                            127 ___ FC7              690 ___ Y7
                                                            200 ___ L7                
                                                                           
                                                            Standard Coil                Low Consumption
                                                            DC Volts ___Code          DC Volts ___Code
                                                            12 ___ JD                           5 ___ AL
                                                            24 ___ BD                         12 ___ JL
                                                            36 ___ CD                         20 ___ ZL
                                                            48 ___ ED                         24 ___ BL
                                                            60 ___ ND                         48 ___ EL
                                                            72 ___ SD                         72 ___ SL
                                                            110 ___ FD                       96 ___ DL
                                                            125 ___ GD                     110 ___ FL
                                                            220 ___ MD                    220 ___ ML
                                                            250 ___ UD                     250 ___ UL
                                                            440 ___ RD                
                                                            Show More