Quantcast

TeSys D Contactor, 3P(3 NO), AC-3, <= 440v,="" 32a,="" 60vdc,="" standard="">

TeSys D Contactor, 3P(3 NO), AC-3, <= 440v,="" 32a,="" 60vdc,="" standard="">

TeSys D Contactor, 3P(3 NO), AC-3, <= 440v,="" 32a,="" 60vdc,="" standard="">

Item Number: LC1D32ND

Product Dimensions

Width icon

Width45 mm

Height icon

Height85 mm

Depth icon

Depth101 mm

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Sustainable offer status

Green Premium product

Warranty

18 months

Range of product

  • TeSys D
  • TeSys Deca

Range

  • TeSys
  • TeSys Deca

Product or component type

contactor

Physical

Insulation resistance

> 10 MOhm for signalling circuit

IP degree of protection

IP20 front face conforming to IEC 60529

Climatic withstand

  • conforming to IACS E10
  • conforming to IEC 60947-1 Annex Q category D

Ambient air temperature for operation

  • -40...60 °C
  • 60...70 °C with derating

Ambient air temperature for storage

-60...80 °C

Height

85 mm

Width

45 mm

Depth

101 mm

Net weight

0.535 kg

REACh Regulation

Reference contains Substances of Very High Concern above the threshold

EU RoHS Directive

Compliant

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

Product out of China RoHS scope. Substance declaration for your information

Environmental Disclosure

ENVPEP110229EN

Circularity Profile

ENVEOLI1102029EN

[Ue] rated operational voltage

  • power circuit: <= 690="" v="" ac="" 25...400="">
  • power circuit: <= 300="" v="">

[Ie] rated operational current

  • 32 A (at <60 °c)="" at=""><= 440="" v="" ac="" ac-3="" for="" power="">
  • 50 A (at <60 °c)="" at=""><= 440="" v="" ac="" ac-1="" for="" power="">
  • 32 A (at <60 °c)="" at=""><= 440="" v="" ac="" ac-3e="" for="" power="">

Electrical durability

  • 1.65 Mcycles 32 A AC-3 at Ue <= 440="">
  • 1.4 Mcycles 50 A AC-1 at Ue <= 440="">
  • 1.65 Mcycles 32 A AC-3e at Ue <= 440="">

Mounting support

  • rail
  • plate

Standards

  • CSA C22.2 No 14
  • EN 60947-4-1
  • EN 60947-5-1
  • IEC 60947-4-1
  • IEC 60947-5-1
  • UL 508
  • IEC 60335-1

Product certifications

  • LROS (Lloyds register of shipping)
  • BV
  • GOST
  • CCC
  • UL
  • DNV
  • RINA
  • CSA
  • GL

Connections - terminals

  • control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end
  • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end
  • control circuit: screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end
  • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible with cable end
  • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²solid without cable end
  • control circuit: screw clamp terminals 2 cable(s) 1-4 mm²solid without cable end
  • power circuit: screw clamp terminals 1 cable(s) 2.5-10 mm²flexible without cable end
  • power circuit: screw clamp terminals 2 cable(s) 2.5-10 mm²flexible without cable end
  • power circuit: screw clamp terminals 1 cable(s) 1-10 mm²flexible with cable end
  • power circuit: screw clamp terminals 2 cable(s) 1.5-6 mm²flexible with cable end
  • power circuit: screw clamp terminals 1 cable(s) 1.5-10 mm²solid without cable end
  • power circuit: screw clamp terminals 2 cable(s) 2.5-10 mm²solid without cable end

Mechanical durability

30 Mcycles

Others

Coil technology

built-in bidirectional peak limiting diode suppressor

Control circuit voltage limits

  • 0.1...0.25 Uc (-40-70 °C):drop-out DC
  • 0.7...1.25 Uc (-40-60 °C):operational DC
  • 1...1.25 Uc (60-70 °C):operational DC

Time constant

28 ms

Inrush power in W

5.4...5.4 W (at 20 °C)

Hold-in power consumption in W

5.4...5.4 W at 20 °C

Auxiliary contacts type

  • type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
  • type mirror contact 1 NC conforming to IEC 60947-4-1

Signalling circuit frequency

25...400 Hz

Minimum switching current

5 mA for signalling circuit

Minimum switching voltage

17 V for signalling circuit

Non-overlap time

  • 1.5 ms on de-energisation between NC and NO contact
  • 1.5 ms on energisation between NC and NO contact

Contact compatibility

M4

Compatibility code

LC1D

Protective treatment

TH conforming to IEC 60068-2-30

Pollution degree

3

Operating altitude

0...3000 m

Fire resistance

850 °C conforming to IEC 60695-2-1

Flame retardance

V1 conforming to UL 94

Mechanical robustness

  • vibrations contactor open: 2 Gn, 5...300 Hz
  • vibrations contactor closed: 4 Gn, 5...300 Hz
  • shocks contactor closed: 15 Gn for 11 ms
  • shocks contactor open: 8 Gn for 11 ms

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Weight

586.0 g

Package 1 Height

5.4 cm

Package 1 width

12 cm

Package 1 Length

9.6 cm

Unit Type of Package 2

S02

Number of Units in Package 2

15

Package 2 Weight

9.089 kg

Package 2 Height

15 cm

Package 2 width

30 cm

Package 2 Length

40 cm

Package 3 Height

77 cm

WEEE

The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

PVC free

Yes

Product name

  • TeSys D
  • TeSys Deca

Device short name

LC1D

Contactor application

  • resistive load
  • motor control

Utilisation category

  • AC-3
  • AC-1
  • AC-3e

Poles description

3P

Pole contact composition

3 NO

Motor power kW

  • 7.5 kW at 220...230 V AC 50/60 Hz (AC-3)
  • 15 kW at 380...400 V AC 50/60 Hz (AC-3)
  • 15 kW at 415...440 V AC 50/60 Hz (AC-3)
  • 18.5 kW at 500 V AC 50/60 Hz (AC-3)
  • 18.5 kW at 660...690 V AC 50/60 Hz (AC-3)
  • 7.5 kW at 400 V AC 50/60 Hz (AC-4)
  • 7.5 kW at 220...230 V AC 50/60 Hz (AC-3e)
  • 15 kW at 380...400 V AC 50/60 Hz (AC-3e)
  • 15 kW at 415...440 V AC 50/60 Hz (AC-3e)
  • 18.5 kW at 500 V AC 50/60 Hz (AC-3e)
  • 18.5 kW at 660...690 V AC 50/60 Hz (AC-3e)

Motor power hp

  • 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors
  • 10 hp at 230/240 V AC 50/60 Hz for 3 phases motors
  • 30 hp at 575/600 V AC 50/60 Hz for 3 phases motors
  • 2 hp at 115 V AC 50/60 Hz for 1 phase motors
  • 7.5 hp at 200/208 V AC 50/60 Hz for 3 phases motors
  • 20 hp at 460/480 V AC 50/60 Hz for 3 phases motors

Control circuit type

DC standard

[Uc] control circuit voltage

60 V DC

Auxiliary contact composition

1 NO + 1 NC

[Uimp] rated impulse withstand voltage

6 kV conforming to IEC 60947

Overvoltage category

III

[Ith] conventional free air thermal current

  • 10 A (at 60 °C) for signalling circuit
  • 50 A (at 60 °C) for power circuit

Irms rated making capacity

  • 140 A AC for signalling circuit conforming to IEC 60947-5-1
  • 250 A DC for signalling circuit conforming to IEC 60947-5-1
  • 550 A at 440 V for power circuit conforming to IEC 60947

Rated breaking capacity

550 A at 440 V for power circuit conforming to IEC 60947

[Icw] rated short-time withstand current

  • 60 A 40 °C - 10 min for power circuit
  • 138 A 40 °C - 1 min for power circuit
  • 260 A 40 °C - 10 s for power circuit
  • 430 A 40 °C - 1 s for power circuit
  • 100 A - 1 s for signalling circuit
  • 120 A - 500 ms for signalling circuit
  • 140 A - 100 ms for signalling circuit

Associated fuse rating

  • 10 A gG for signalling circuit conforming to IEC 60947-5-1
  • 63 A gG at <= 690="" v="" coordination="" type="" 1="" for="" power="">
  • 63 A gG at <= 690="" v="" coordination="" type="" 2="" for="" power="">

Average impedance

2 mOhm - Ith 50 A 50 Hz for power circuit

[Ui] rated insulation voltage

  • power circuit: 600 V CSA certified
  • power circuit: 600 V UL certified
  • signalling circuit: 690 V conforming to IEC 60947-1
  • signalling circuit: 600 V CSA certified
  • signalling circuit: 600 V UL certified
  • power circuit: 690 V conforming to IEC 60947-4-1

Power dissipation per pole

  • 2 W AC-3
  • 5 W AC-1
  • 2 W AC-3e

Protective cover

with

Tightening torque

  • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
  • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
  • power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
  • power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver Philips No 2
  • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
  • power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver pozidriv No 2

Operating time

  • 16...24 ms opening
  • 53.55...72.45 ms closing

Safety reliability level

  • B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
  • B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1

Maximum operating rate

3600 cyc/h 60 °C
Show all specifications