Range of product

  • TeSys D
  • TeSys Deca

Range

  • TeSys
  • TeSys Deca

Product or component type

contactor

Sustainable offer status

Green Premium product

Warranty

18 months

Physical

[Ue] rated operational voltage

  • power circuit: <= 690="" v="" ac="" 25...400="">
  • power circuit: <= 300="" v="">

[Ie] rated operational current

  • 25 A (at <60 °c)="" at=""><= 440="" v="" ac="" ac-3="" for="" power="">
  • 40 A (at <60 °c)="" at=""><= 440="" v="" ac="" ac-1="" for="" power="">
  • 25 A (at <60 °c)="" at=""><= 440="" v="" ac="" ac-3e="" for="" power="">

Electrical durability

  • 1.65 Mcycles 25 A AC-3 at Ue <= 440="">
  • 1.4 Mcycles 40 A AC-1 at Ue <= 440="">
  • 1.65 Mcycles 25 A AC-3e at Ue <= 440="">

Mounting support

  • rail
  • plate

Standards

  • CSA C22.2 No 14
  • EN 60947-4-1
  • EN 60947-5-1
  • IEC 60947-4-1
  • IEC 60947-5-1
  • UL 508
  • IEC 60335-1

Product certifications

  • UL
  • BV
  • RINA
  • GOST
  • DNV
  • LROS (Lloyds register of shipping)
  • CCC
  • GL
  • CSA
  • UKCA

Connections - terminals

  • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end
  • control circuit: screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end
  • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible with cable end
  • control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end
  • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²solid without cable end
  • control circuit: screw clamp terminals 2 cable(s) 1-4 mm²solid without cable end
  • power circuit: screw clamp terminals 1 cable(s) 2.5-10 mm²flexible without cable end
  • power circuit: screw clamp terminals 2 cable(s) 2.5-10 mm²flexible without cable end
  • power circuit: screw clamp terminals 1 cable(s) 1-10 mm²flexible with cable end
  • power circuit: screw clamp terminals 2 cable(s) 1.5-6 mm²flexible with cable end
  • power circuit: screw clamp terminals 1 cable(s) 1.5-10 mm²solid without cable end
  • power circuit: screw clamp terminals 2 cable(s) 2.5-10 mm²solid without cable end

Mechanical durability

15 Mcycles

Insulation resistance

> 10 MOhm for signalling circuit

IP degree of protection

IP20 front face conforming to IEC 60529

Climatic withstand

  • conforming to IACS E10
  • conforming to IEC 60947-1 Annex Q category D

Ambient air temperature for operation

  • -40...60 °C
  • 60...70 °C with derating

Ambient air temperature for storage

-60...80 °C

Height

85 mm

Width

45 mm

Depth

92 mm

Net weight

0.37 kg

REACh Regulation

Free of Substances of Very High Concern above the threshold

REACh free of SVHC

Yes

EU RoHS Directive

Compliant

Toxic heavy metal free

Yes

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

 Pro-active China RoHS declaration (out of China RoHS legal scope)

Environmental Disclosure

ENVPEP110229EN

Circularity Profile

ENVEOLI1102029EN

California proposition 65

WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov

Others

Product name

  • TeSys D
  • TeSys Deca

Device short name

LC1D

Contactor application

  • motor control
  • resistive load

Utilisation category

  • AC-3
  • AC-4
  • AC-1
  • AC-3e

Poles description

3P

Pole contact composition

3 NO

Motor power kW

  • 5.5 kW at 220...230 V AC 50/60 Hz (AC-3)
  • 11 kW at 380...400 V AC 50/60 Hz (AC-3)
  • 11 kW at 415...440 V AC 50/60 Hz (AC-3)
  • 15 kW at 500 V AC 50/60 Hz (AC-3)
  • 15 kW at 660...690 V AC 50/60 Hz (AC-3)
  • 5.5 kW at 400 V AC 50/60 Hz (AC-4)
  • 5.5 kW at 220...230 V AC 50/60 Hz (AC-3e)
  • 11 kW at 380...400 V AC 50/60 Hz (AC-3e)
  • 11 kW at 415...440 V AC 50/60 Hz (AC-3e)
  • 15 kW at 500 V AC 50/60 Hz (AC-3e)
  • 15 kW at 660...690 V AC 50/60 Hz (AC-3e)

Motor power hp

  • 3 hp at 230/240 V AC 50/60 Hz for 1 phase motors
  • 2 hp at 115 V AC 50/60 Hz for 1 phase motors
  • 7.5 hp at 230/240 V AC 50/60 Hz for 3 phases motors
  • 15 hp at 460/480 V AC 50/60 Hz for 3 phases motors
  • 20 hp at 575/600 V AC 50/60 Hz for 3 phases motors
  • 7.5 hp at 200/208 V AC 50/60 Hz for 3 phases motors

Control circuit type

AC at 50/60 Hz

[Uc] control circuit voltage

120 V AC 50/60 Hz

Auxiliary contact composition

1 NO + 1 NC

[Uimp] rated impulse withstand voltage

6 kV conforming to IEC 60947

Overvoltage category

III

[Ith] conventional free air thermal current

  • 10 A (at 60 °C) for signalling circuit
  • 40 A (at 60 °C) for power circuit

Irms rated making capacity

  • 140 A AC for signalling circuit conforming to IEC 60947-5-1
  • 250 A DC for signalling circuit conforming to IEC 60947-5-1
  • 450 A at 440 V for power circuit conforming to IEC 60947

Rated breaking capacity

450 A at 440 V for power circuit conforming to IEC 60947

[Icw] rated short-time withstand current

  • 240 A 40 °C - 10 s for power circuit
  • 380 A 40 °C - 1 s for power circuit
  • 50 A 40 °C - 10 min for power circuit
  • 120 A 40 °C - 1 min for power circuit
  • 100 A - 1 s for signalling circuit
  • 120 A - 500 ms for signalling circuit
  • 140 A - 100 ms for signalling circuit

Associated fuse rating

  • 10 A gG for signalling circuit conforming to IEC 60947-5-1
  • 63 A gG at <= 690="" v="" coordination="" type="" 1="" for="" power="">
  • 40 A gG at <= 690="" v="" coordination="" type="" 2="" for="" power="">

Average impedance

2 mOhm - Ith 40 A 50 Hz for power circuit

[Ui] rated insulation voltage

  • power circuit: 690 V conforming to IEC 60947-4-1
  • power circuit: 600 V CSA certified
  • power circuit: 600 V UL certified
  • signalling circuit: 690 V conforming to IEC 60947-1
  • signalling circuit: 600 V CSA certified
  • signalling circuit: 600 V UL certified

Power dissipation per pole

  • 3.2 W AC-1
  • 1.25 W AC-3
  • 1.25 W AC-3e

Protective cover

with

Tightening torque

  • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
  • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
  • power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
  • power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver Philips No 2
  • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
  • power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver pozidriv No 2

Operating time

  • 12...22 ms closing
  • 4...19 ms opening

Safety reliability level

  • B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
  • B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1

Maximum operating rate

3600 cyc/h 60 °C

Coil technology

without built-in suppressor module

Control circuit voltage limits

  • 0.3...0.6 Uc (-40-70 °C):drop-out AC 50/60 Hz
  • 0.8...1.1 Uc (-40-60 °C):operational AC 50 Hz
  • 0.85...1.1 Uc (-40-60 °C):operational AC 60 Hz
  • 1...1.1 Uc (60-70 °C):operational AC 50/60 Hz

Inrush power in VA

  • 70 VA 60 Hz cos phi 0.75 (at 20 °C)
  • 70 VA 50 Hz cos phi 0.75 (at 20 °C)

Hold-in power consumption in VA

  • 7.5...7.5 VA 60 Hz cos phi 0.3 (at 20 °C)
  • 7 VA 50 Hz cos phi 0.3 (at 20 °C)

Heat dissipation

2...3 W at 50/60 Hz

Auxiliary contacts type

  • type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
  • type mirror contact 1 NC conforming to IEC 60947-4-1

Signalling circuit frequency

25...400 Hz

Minimum switching current

5 mA for signalling circuit

Minimum switching voltage

17 V for signalling circuit

Non-overlap time

  • 1.5 ms on de-energisation between NC and NO contact
  • 1.5 ms on energisation between NC and NO contact

Contact compatibility

M2

Compatibility code

LC1D

Power range

  • 4...6 kW at 200...240 V 3 phases
  • 7...11 kW at 380...440 V 3 phases
  • 7...11 kW at 480...500 V 3 phases
  • 2.2...3 kW at 100...120 V 3 phases
  • 15...25 kW at 525...690 V 3 phases

Motor starter type

direct on-line contactor

Protective treatment

TH conforming to IEC 60068-2-30

Pollution degree

3

Operating altitude

0...3000 m

Fire resistance

850 °C conforming to IEC 60695-2-1

Flame retardance

V1 conforming to UL 94

Mechanical robustness

  • vibrations contactor open: 2 Gn, 5...300 Hz
  • vibrations contactor closed: 4 Gn, 5...300 Hz
  • shocks contactor closed: 15 Gn for 11 ms
  • shocks contactor open: 8 Gn for 11 ms

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Weight

410.8 g

Package 1 Height

5 cm

Package 1 width

9.5 cm

Package 1 Length

11.5 cm

Unit Type of Package 2

S02

Number of Units in Package 2

20

Package 2 Weight

8.475 kg

Package 2 Height

15 cm

Package 2 width

30 cm

Package 2 Length

40 cm

Unit Type of Package 3

P06

Number of Units in Package 3

320

Package 3 Weight

143.6 kg

Package 3 Height

75 cm

Package 3 width

80 cm

Package 3 Length

60 cm

WEEE

The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

PVC free

Yes
Show all specifications

Documents & downloads

hide show
Filter items
  • All

  • CAD Files and Packs

  • Product Brochures

  • Technical Data Catalogues

  • Installation Instruction

  • Data Bulletin

  • End of Life Manual

  • Product Environmental

  • Handout

  • Technical Drawing

  • Certificates (MSDS)

  • Declaration of Conformity

Frequently Asked Questions

hide show

What is the difference between the LAD4TB and LAD4TBDL bi-directional peak limiting diode?

Issue:
Identifying the difference between LAD4TB and LAD4TBDL

Product Line:
IEC contactors and starters

Environment:
Products sold and used in the United States

Cause:
Identifying the difference between two similar part numbers

Resolution:
The LAD4TB is for 24V AC coils for the Tesys Series LC1D09 through LC1D38 contactors when supplied with G7 voltage code. The LAD4TBDL is 24 vdc bi-directional diode offered as a replacement if for some reason the diode supplied with the Tesys LC1D09 through LC1D38 contactors when ordered with BD or BL voltage code breaks or is no longer working.


 

Difference between older D2 LC1D contactors and newer LC1D contactors

Issue:
What is the difference between the older D2 style contactors where aux contacts had to be specified and the newer LC1D contactors?

Product Line:
TeSysD contactors

Environment:
US product

Cause:
Crossing into new units from old units require a review of differences

Resolution:
The older D2 style contactors required a specification of needed auxiliary contacts.  For example:

LC1D2501G6 would be an LC1D25 with 1 NC contact
LC1D2510G6 would be an LC1D25 with 1 NO contact

The newer contactors automatically come with 1 NO and 1 NC auxiliary contact.  For example:
LC1D25G7 has 1 NO and 1 NC contact

The older contactors usually had a dedicated 60hz coil.  This is designated by the 6 at the end of the part number.  The newer contactors have coils designed for 50/60hz and are signified by the 7 at the end of the part number.