Quantcast

TeSys D, Contactor, TeSys Deca, 3P(3NO), AC-3/AC-3e, <=440v, 150a,="" 120v="" ac="" 50/60hz="" coil,="" lugs/bars="">

TeSys D, Contactor, TeSys Deca, 3P(3NO), AC-3/AC-3e, <=440v, 150a,="" 120v="" ac="" 50/60hz="" coil,="" lugs/bars="">

TeSys D, Contactor, TeSys Deca, 3P(3NO), AC-3/AC-3e, <=440v, 150a,="" 120v="" ac="" 50/60hz="" coil,="" lugs/bars="">

Item Number: LC1D1506G7

Datasheet

Product Dimensions

Width icon

Width120 mm

Height icon

Height158 mm

Depth icon

Depth136 mm

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range

TeSys

Range of product

TeSys Deca

Product or component type

contactor

Sustainable offer status

Green Premium product

Warranty

18 months

Physical

[Ue] rated operational voltage

  • power circuit: <= 1000="" v="" ac="" 25...400="">
  • power circuit: <= 300="" v="">

[Ie] rated operational current

  • 200 A (at <60 °c)="" at=""><= 440="" v="" ac="" ac-1="" for="" power="">
  • 150 A (at <60 °c)="" at=""><= 440="" v="" ac="" ac-3="" for="" power="">
  • 150 A (at <60 °c)="" at=""><= 440="" v="" ac="" ac-3e="" for="" power="">

Mechanical durability

8 Mcycles

Electrical durability

  • 0.85 Mcycles 150 A AC-3 at Ue <= 440="">
  • 1 Mcycles 200 A AC-1 at Ue <= 440="">
  • 0.85 Mcycles 150 A AC-3e at Ue <= 440="">

Connections - terminals

  • control circuit: lugs-ring terminals - external diameter: 8 mm
  • power circuit: lugs-ring terminals - external diameter: 25 mm
  • power circuit: bars 1 - busbar cross section: 5 x 25 mm

Insulation resistance

> 10 MOhm for signalling circuit

Mounting support

  • rail
  • plate

Standards

  • CSA C22.2 No 14
  • EN 60947-4-1
  • EN 60947-5-1
  • IEC 60947-4-1
  • IEC 60947-5-1
  • UL 508

Product certifications

  • CSA
  • UL
  • DNV
  • GOST
  • RINA
  • LROS (Lloyds register of shipping)
  • GL
  • CCC
  • BV
  • UKCA
  • CE

IP degree of protection

IP20 front face conforming to IEC 60529

Climatic withstand

conforming to IACS E10 exposure to damp heat

Height

158 mm

Width

120 mm

Depth

136 mm

Net weight

2.5 kg

REACh Regulation

Reference contains Substances of Very High Concern above the threshold

EU RoHS Directive

Compliant

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

Product out of China RoHS scope. Substance declaration for your information

Environmental Disclosure

ENVPEP060301EN

Circularity Profile

ENVEOLI100405

California proposition 65

WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov

Others

Package 1 Bare Product Quantity

1

Device short name

LC1D

Contactor application

  • motor control
  • resistive load

Utilisation category

  • AC-3
  • AC-4
  • AC-1
  • AC-3e

Poles description

3P

[Uc] control circuit voltage

120 V AC 50/60 Hz

Motor power kW

  • 40 kW at 220...230 V AC 50/60 Hz (AC-3)
  • 75 kW at 380...400 V AC 50/60 Hz (AC-3)
  • 80 kW at 415...440 V AC 50/60 Hz (AC-3)
  • 90 kW at 500 V AC 50/60 Hz (AC-3)
  • 100 kW at 660...690 V AC 50/60 Hz (AC-3)
  • 75 kW at 1000 V AC 50/60 Hz (AC-3)
  • 22 kW at 400 V AC 50/60 Hz (AC-4)
  • 40 kW at 220...230 V AC 50/60 Hz (AC-3e)
  • 75 kW at 380...400 V AC 50/60 Hz (AC-3e)
  • 80 kW at 415...440 V AC 50/60 Hz (AC-3e)
  • 90 kW at 500 V AC 50/60 Hz (AC-3e)
  • 100 kW at 660...690 V AC 50/60 Hz (AC-3e)
  • 75 kW at 1000 V AC 50/60 Hz (AC-3e)

Motor power hp

  • 40 hp at 200/208 V AC 50/60 Hz for 3 phases motors
  • 50 hp at 230/240 V AC 50/60 Hz for 3 phases motors
  • 100 hp at 460/480 V AC 50/60 Hz for 3 phases motors
  • 125 hp at 575/600 V AC 50/60 Hz for 3 phases motors

Compatibility code

LC1D

Pole contact composition

3 NO

Contact compatibility

M13

Protective cover

with

[Ith] conventional free air thermal current

200 A (at 60 °C) for power circuit

Irms rated making capacity

  • 140 A AC for signalling circuit conforming to IEC 60947-5-1
  • 250 A DC for signalling circuit conforming to IEC 60947-5-1
  • 1660 A at 440 V for power circuit conforming to IEC 60947

Rated breaking capacity

1400 A at 440 V for power circuit conforming to IEC 60947

[Icw] rated short-time withstand current

  • 250 A 40 °C - 10 min for power circuit
  • 580 A 40 °C - 1 min for power circuit
  • 1200 A 40 °C - 10 s for power circuit
  • 1400 A 40 °C - 1 s for power circuit
  • 100 A - 1 s for signalling circuit
  • 120 A - 500 ms for signalling circuit
  • 140 A - 100 ms for signalling circuit

Associated fuse rating

  • 10 A gG for signalling circuit conforming to IEC 60947-5-1
  • 315 A gG at <= 690="" v="" coordination="" type="" 1="" for="" power="">
  • 250 A gG at <= 690="" v="" coordination="" type="" 2="" for="" power="">

Average impedance

0.6 mOhm - Ith 200 A 50 Hz for power circuit

Power dissipation per pole

  • 24 W AC-1
  • 13.5 W AC-3
  • 13.5 W AC-3e

[Ui] rated insulation voltage

  • power circuit: 600 V CSA certified
  • power circuit: 600 V UL certified
  • power circuit: 1000 V conforming to IEC 60947-4-1
  • signalling circuit: 690 V conforming to IEC 60947-1
  • signalling circuit: 600 V CSA certified
  • signalling circuit: 600 V UL certified

Overvoltage category

III

Pollution degree

3

[Uimp] rated impulse withstand voltage

8 kV conforming to IEC 60947

Safety reliability level

  • B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
  • B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1

Control circuit type

AC at 50/60 Hz

Coil technology

built-in bidirectional peak limiting diode suppressor

Control circuit voltage limits

  • 0.3...0.5 Uc (-40-70 °C):drop-out AC 50/60 Hz
  • 0.8...1.15 Uc (-40-55 °C):operational AC 50/60 Hz
  • 1...1.15 Uc (55-70 °C):operational AC 50/60 Hz

Inrush power in VA

  • 280...350 VA 60 Hz cos phi 0.9 (at 20 °C)
  • 280...350 VA 50 Hz cos phi 0.9 (at 20 °C)

Hold-in power consumption in VA

  • 2...18 VA 60 Hz cos phi 0.9 (at 20 °C)
  • 2...18 VA 50 Hz cos phi 0.9 (at 20 °C)

Heat dissipation

3...4.5 W at 50/60 Hz

Operating time

  • 20...35 ms closing
  • 40...75 ms opening

Maximum operating rate

1200 cyc/h 60 °C

Tightening torque

  • control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver flat Ø 6 mm M3.5
  • control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver Philips No 2 M3.5
  • power circuit: 12 N.m - on lugs-ring terminals hexagonal screw head 13 mm M8
  • power circuit: 12 N.m - on bars hexagonal screw head 13 mm M8
  • control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver pozidriv No 2 M3.5

Auxiliary contact composition

1 NO + 1 NC

Auxiliary contacts type

  • type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
  • type mirror contact 1 NC conforming to IEC 60947-4-1

Signalling circuit frequency

25...400 Hz

Minimum switching voltage

17 V for signalling circuit

Minimum switching current

5 mA for signalling circuit

Non-overlap time

  • 1.5 ms on de-energisation between NC and NO contact
  • 1.5 ms on energisation between NC and NO contact

Protective treatment

TH conforming to IEC 60068-2-30

Permissible ambient air temperature around the device

  • -40...60 °C
  • 60...70 °C with derating

Operating altitude

0...3000 m

Fire resistance

850 °C conforming to IEC 60695-2-1

Flame retardance

V1 conforming to UL 94

Mechanical robustness

  • vibrations contactor open (2 Gn, 5...300 Hz)
  • vibrations contactor closed (4 Gn, 5...300 Hz)
  • shocks contactor closed (15 Gn for 11 ms)
  • shocks contactor open (6 Gn for 11 ms)

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Height

16.800 cm

Package 1 Width

20.800 cm

Package 1 Length

18.500 cm

Package 1 Weight

2.130 kg

Unit Type of Package 2

S03

Number of Units in Package 2

2

Package 2 Height

30.000 cm

Package 2 Width

30.000 cm

Package 2 Length

40.000 cm

Package 2 Weight

4.680 kg

Unit Type of Package 3

P06

Number of Units in Package 3

16

Package 3 Height

75.000 cm

Package 3 Width

80.000 cm

Package 3 Length

60.000 cm

Package 3 Weight

45.440 kg

WEEE

The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

PVC free

Yes
Show all specifications