TeSys LC1D contactor - 3 poles - screw clamp terminals or lugs - with cover - 9A to 18A AC coil

TeSys D Contactor, 3P(3 NO), AC-3, <= 440V, 12A, 12VAC Coil

Catalogue Number: LC1D12J7
TeSys LC1D contactor - 3 poles - screw clamp terminals or lugs - with cover - 9A to 18A AC coil
Retail
$289.96
RRP (Inc. GST)

Specifications

hide show
Range of product
TeSys D
Range
TeSys
Product name
TeSys D
Product or component type
contactor
Device short name
LC1D
Contactor application
  • resistive load
  • motor control
    • Utilisation category
    • AC-3
    • AC-4
    • AC-1
      • Poles description
        3P
        Pole contact composition
        3 NO
        [Ue] rated operational voltage
      • power circuit: <= 690 V AC 25...400 Hz
      • power circuit: <= 300 V DC
        • [Ie] rated operational current
        • 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
        • 12 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
          • Motor power kW
          • 3 kW at 220...230 V AC 50/60 Hz (AC-3)
          • 5.5 kW at 380...400 V AC 50/60 Hz (AC-3)
          • 5.5 kW at 415...440 V AC 50/60 Hz (AC-3)
          • 7.5 kW at 500 V AC 50/60 Hz (AC-3)
          • 7.5 kW at 660...690 V AC 50/60 Hz (AC-3)
          • 3.7 kW at 400 V AC 50/60 Hz (AC-4)
            • Motor power hp
            • 0.5 hp at 115 V AC 50/60 Hz for 1 phase motors
            • 2 hp at 230/240 V AC 50/60 Hz for 1 phase motors
            • 3 hp at 200/208 V AC 50/60 Hz for 3 phases motors
            • 3 hp at 230/240 V AC 50/60 Hz for 3 phases motors
            • 7.5 hp at 460/480 V AC 50/60 Hz for 3 phases motors
            • 10 hp at 575/600 V AC 50/60 Hz for 3 phases motors
              • Control circuit type
                AC at 50/60 Hz
                [Uc] control circuit voltage
                12 V AC 50/60 Hz
                Auxiliary contact composition
                1 NO + 1 NC
                [Uimp] rated impulse withstand voltage
                6 kV conforming to IEC 60947
                Overvoltage category
                III
                [Ith] conventional free air thermal current
              • 25 A (at 60 °C) for power circuit
              • 10 A (at 60 °C) for signalling circuit
                • Irms rated making capacity
                • 250 A at 440 V for power circuit conforming to IEC 60947
                • 140 A AC for signalling circuit conforming to IEC 60947-5-1
                • 250 A DC for signalling circuit conforming to IEC 60947-5-1
                  • Rated breaking capacity
                    250 A at 440 V for power circuit conforming to IEC 60947
                    [Icw] rated short-time withstand current
                  • 105 A 40 °C - 10 s for power circuit
                  • 210 A 40 °C - 1 s for power circuit
                  • 30 A 40 °C - 10 min for power circuit
                  • 61 A 40 °C - 1 min for power circuit
                  • 100 A - 1 s for signalling circuit
                  • 120 A - 500 ms for signalling circuit
                  • 140 A - 100 ms for signalling circuit
                    • Associated fuse rating
                    • 10 A gG for signalling circuit conforming to IEC 60947-5-1
                    • 40 A gG at <= 690 V coordination type 1 for power circuit
                    • 25 A gG at <= 690 V coordination type 2 for power circuit
                      • Average impedance
                        2.5 mOhm - Ith 25 A 50 Hz for power circuit
                        [Ui] rated insulation voltage
                      • power circuit: 690 V conforming to IEC 60947-4-1
                      • power circuit: 600 V CSA certified
                      • power circuit: 600 V UL certified
                      • signalling circuit: 690 V conforming to IEC 60947-1
                      • signalling circuit: 600 V CSA certified
                      • signalling circuit: 600 V UL certified
                        • Electrical durability
                        • 2 Mcycles 12 A AC-3 at Ue <= 440 V
                        • 0.8 Mcycles 25 A AC-1 at Ue <= 440 V
                          • Power dissipation per pole
                          • 0.36 W AC-3
                          • 1.56 W AC-1
                            • Protective cover
                              with
                              Mounting support
                            • rail
                            • plate
                              • Standards
                              • CSA C22.2 No 14
                              • EN 60947-4-1
                              • EN 60947-5-1
                              • IEC 60947-4-1
                              • IEC 60947-5-1
                              • UL 508
                                • Product certifications
                                • BV
                                • GOST
                                • CCC
                                • GL
                                • LROS (Lloyds register of shipping)
                                • DNV
                                • CSA
                                • RINA
                                • UL
                                  • Connections - terminals
                                  • power circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end
                                  • power circuit: screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end
                                  • power circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible with cable end
                                  • power circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end
                                  • power circuit: screw clamp terminals 1 cable(s) 1-4 mm²solid without cable end
                                  • power circuit: screw clamp terminals 2 cable(s) 1-4 mm²solid without cable end
                                  • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end
                                  • control circuit: screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end
                                  • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible with cable end
                                  • control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end
                                  • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²solid without cable end
                                  • control circuit: screw clamp terminals 2 cable(s) 1-4 mm²solid without cable end
                                    • Tightening torque
                                    • power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
                                    • power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
                                    • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
                                    • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
                                      • Operating time
                                      • 12...22 ms closing
                                      • 4...19 ms opening
                                        • Safety reliability level
                                        • B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
                                        • B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
                                          • Mechanical durability
                                            15 Mcycles
                                            Maximum operating rate
                                            3600 cyc/h 60 °C
                                            Coil technology
                                            without built-in suppressor module
                                            Inrush power in VA
                                          • 70-70 VA 60 Hz cos phi 0.75 (at 20 °C)
                                          • 70-70 VA 50 Hz cos phi 0.75 (at 20 °C)
                                            • Hold-in power consumption in VA
                                            • 7.5-7.5 VA 60 Hz cos phi 0.3 (at 20 °C)
                                            • 7-7 VA 50 Hz cos phi 0.3 (at 20 °C)
                                              • Heat dissipation
                                                2-3 W at 50/60 Hz
                                                Auxiliary contacts type
                                              • type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
                                              • type mirror contact 1 NC conforming to IEC 60947-4-1
                                                • Signalling circuit frequency
                                                  25...400 Hz
                                                  Minimum switching current
                                                  5 mA for signalling circuit
                                                  Minimum switching voltage
                                                  17 V for signalling circuit
                                                  Non-overlap time
                                                • 1.5 ms on de-energisation between NC and NO contact
                                                • 1.5 ms on energisation between NC and NO contact
                                                  • Insulation resistance
                                                    > 10 MOhm for signalling circuit
                                                    Contact compatibility
                                                    M2
                                                    Compatibility code
                                                    LC1D
                                                    Power range
                                                  • 4-6 kW at 380-440 V 3 phases
                                                  • 4-6 kW at 480-500 V 3 phases
                                                  • 1.1-2 kW at 100-120 V 3 phases
                                                  • 2.2-3 kW at 200-240 V 3 phases
                                                  • 7-11 kW at 525-690 V 3 phases
                                                    • Motor starter type
                                                      direct on-line contactor
                                                      IP degree of protection
                                                      IP20 front face conforming to IEC 60529
                                                      Protective treatment
                                                      TH conforming to IEC 60068-2-30
                                                      Pollution degree
                                                      3
                                                      Ambient air temperature for storage
                                                      -60-80 °C
                                                      Operating altitude
                                                      3000 m without derating
                                                      Fire resistance
                                                      850 °C conforming to IEC 60695-2-1
                                                      Flame retardance
                                                      V1 conforming to UL 94
                                                      Mechanical robustness
                                                    • vibrations contactor open: 2 Gn, 5...300 Hz
                                                    • vibrations contactor closed: 4 Gn, 5...300 Hz
                                                    • shocks contactor open: 10 Gn for 11 ms
                                                    • shocks contactor closed: 15 Gn for 11 ms
                                                      • Height
                                                        77 mm
                                                        Width
                                                        45 mm
                                                        Depth
                                                        86 mm
                                                        Net weight
                                                        0.325 kg
                                                        Unit Type of Package 1
                                                        PCE
                                                        Number of Units in Package 1
                                                        1
                                                        Package 1 Weight
                                                        348 g
                                                        Package 1 Height
                                                        5.5 cm
                                                        Package 1 width
                                                        8.2 cm
                                                        Package 1 Length
                                                        9.5 cm
                                                        Sustainable offer status
                                                        Green Premium product
                                                        REACh free of SVHC
                                                        Yes
                                                        EU RoHS Directive
                                                        Compliant
                                                        Toxic heavy metal free
                                                        Yes
                                                        Mercury free
                                                        Yes
                                                        RoHS exemption information
                                                        Yes
                                                        China RoHS Regulation
                                                         Pro-active China RoHS declaration (out of China RoHS legal scope)
                                                        Environmental Disclosure
                                                        ENVPEP1501004EN
                                                        Circularity Profile
                                                        ENVEOLI1501004EN
                                                        WEEE
                                                        The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                                                        PVC free
                                                        Yes
                                                        California proposition 65
                                                        WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.gov
                                                        Warranty
                                                        18 months

                                                        Documents & downloads

                                                        hide show
                                                        Filter items
                                                        • All

                                                        • CAD Files and Packs

                                                        • Product Brochures

                                                        • Technical Data Catalogues

                                                        • Product Environmental

                                                        • End of Life Manual

                                                        • Installation Instruction

                                                        • Data Bulletin

                                                        • Certificates (MSDS)

                                                        • Declaration of Conformity

                                                        Frequently Asked Questions

                                                        hide show

                                                        What is the replacement coil part number for the LC*D09 through LC*D32 and LC*DT20 through LC*DT40 TeSys contactors?

                                                        Issue:
                                                        Identifying replacement coils for tesys D non-reversing and reversing conactors

                                                        Product Line:
                                                        IEC Contactors and Starters

                                                        Environment:
                                                        Products sold and used in the United States

                                                        Cause:
                                                        Replacement coil is needed

                                                        Resolution:
                                                        DC replacement coils are not available.
                                                        AC Coils are 50/60 hertz for voltages as listed below:

                                                        Volts - Part Number
                                                        12 ____ LXD1J7
                                                        21 ____ LXD1Z7
                                                        24 ____ LXD1B7
                                                        32 ____ LXD1C7
                                                        36 ____ LXD1CC7
                                                        42 ____ LXD1D7
                                                        48 ____ LXD1E7
                                                        60 ____ LXD1EE7
                                                        100 ___ LXD1K7 ( never brought to North America )
                                                        110 ___ LXD1F7
                                                        115 ___ LXD1FE7
                                                        120 ___ LXD1G7
                                                        127 ___ LXD1FC7
                                                        200 ___ LXD1L7
                                                        208 ___ LXD1LE7
                                                        220 ___ LXD1M7
                                                        230 ___ LXD1P7
                                                        240 ___ LXD1U7
                                                        277 ___ LXD1W7
                                                        380 ___ LXD1Q7
                                                        400 ___ LXD1V7
                                                        415 ___ LXD1N7
                                                        440 ___ LXD1R7
                                                        480 ___ LXD1T7
                                                        575 ___ LXD1SC7
                                                        600 ___ LXD1X7
                                                        690 ___ LXD1Y7


                                                        Note: A contactor with an AC coil can be changed to a different AC voltage coil, IE you can take an LC1D09 with a 120VAC coil and put a 24VAC coil in it instead. An AC device cannot be switched to a DC coil, and a DC device cannot be switches to an AC coil. 

                                                        Where are the control coil terminals for TeSys LC1D09 to LC1D38 contactor?

                                                        Issue:
                                                        Determine the control coil terminal marking and location on LC1D09 to LC1D38 contactor

                                                        Product Line: 
                                                        Tesys D Contactors

                                                        Environment:
                                                        IEC contactors

                                                        Resolution:
                                                        The coil terminals are marked A1 and A2, you can see them on the front of the contactor on the white part (control section).  They are next to the auxiliary contact (13/14, 21/22) terminals.
                                                         

                                                        What is the maximum UL/CSA AC voltage rating of the LC1D power contacts ?

                                                        Issue:
                                                        Identifying maximum voltage of an LC1D contactor

                                                        Product Line:
                                                        TeSys D Contactors

                                                        Environment:
                                                        IEC contactors and starters used in North America

                                                        Cause:
                                                        n/a

                                                        Resolution:
                                                        IThe maximum voltage per UL and CSA is 600VAC. 
                                                         

                                                        What is the altitude derating for a TeSys D-Line contactor?

                                                        Issue:​
                                                        What is the altitude derating for a TeSys D-Line contactor?

                                                        Product Line:
                                                        Digest 177 Section 18 : Contactors and Starters, IEC

                                                        Environment:
                                                        North American Products

                                                        Resolution:
                                                        The contactors are fully rated up to 3000 meters. Following are derating multipliers for altitudes above 3000 meters for both voltage and current:

                                                        Voltage
                                                        3500m x 0.90
                                                        4000m x 0.80
                                                        4500m x 0.70
                                                        5000m x 0.60

                                                        Current
                                                        3500m x 0.92
                                                        4000m x 0.90
                                                        4500m x 0.88
                                                        5000m x 0.86

                                                        For example, an LC1D80 at 5000 meters:
                                                        - The maximum rated operational voltage is 1,000V (IEC947-4) and 690V (UL/CSA). At 5000 meters it becomes 1000V x 0.6 = 600V (IEC947-4) and 690V x 0.6 = 414V (UL/CSA).
                                                        - The maximum rated operational AC3 current is 80A. At 5000 meters it becomes 80A x 0.86 = 68A.



                                                         

                                                        What is the power terminal lug data for the LC1D09, LC1DT20, LC1D12, and LC1DT25 contactor?

                                                        Issue:
                                                        Power terminal lug data required for the 9 and 12 amp rated Tesys D contactors

                                                        Product Line:
                                                        NEMA combination starters

                                                        Environment:
                                                        Products sold and used in the United States

                                                        Resolution:
                                                        For contactors with screw clamp terminals:
                                                        stranded cable w/o cable end : One or Two #18-10 AWG per terminal.
                                                        stranded cable w/cable end: One or Two #18-10 AWG per terminal.
                                                        solid cable: One or Two #18-8 AWG per terminal.

                                                        Can a GV2AF3 or GV2AF4 interconnection block work on a contactor with a DC coil?

                                                        Issue:
                                                        Mounting adaptor for GV2 and LC1D contactor

                                                        Product Line:
                                                        Motor Starters and Protectors

                                                        Environment:
                                                        TeSys GV Manual Starter and Protectors
                                                        Tesys D Contactors
                                                         
                                                        Resolution:
                                                        The GV2AF3 clip has to be moved to the DC position to accommodate the contactor with a DC coil.

                                                        Are the D-Line contactors rated to break DC voltages?

                                                        Issue: 
                                                        Can the TeSys D line be used to control DC loads? 

                                                        Product Line:
                                                        Tesys D contactors

                                                        Environment:
                                                        Products sold and used in the United States
                                                         
                                                        Cause:
                                                         DC power circuit
                                                         
                                                        Resolution:
                                                         
                                                        Yes, 75 VDC (125 VDC for D115 & D150) per pole which means that through a four pole device breaking 300 VDC is possible by wiring all four power poles in series. However, be aware that the device current ratings will differ according to the number of poles in series and the type of application.

                                                        Devices are suitable but not UL Listed for DC applications.

                                                        More information on their DC ratings can be found in the current TeSys Motor Control and Protection Compentns catalog: https://www.schneider-electric.us/en/download/document/MKTED210011EN/


                                                         

                                                        What is the coil burden for the standard DC control coil for the LC*D09__ through LC*D38__ TeSys contactors?

                                                        Issue:
                                                        LC*D09-38 coil consumption

                                                        Product Line:
                                                        Contactors and Overload Relays

                                                        Environment:
                                                        TeSys™ D Contactors and Overload Relays

                                                        Resolution:
                                                        The standard DC coil is 5.4 watts of consumption.

                                                        What is the power terminal lug data for the LC1D40, LC1D50, LC1D65, LP1D40, LP1D50, and LP1D65 contactor?

                                                        Issue:
                                                        Identifying power terminal lug data for the D2 style contactors

                                                        Product Line:
                                                        Tesys D line contactors

                                                        Environment:
                                                        Products sold and used in the United States

                                                        Cause:
                                                        Power terminal lug data required

                                                        Resolution:
                                                        For contactors with screw clamp terminals:
                                                        stranded cable w/o cable end : One #10-3 AWG or Two #10-4 AWG per terminal.
                                                        stranded cable w/cable end: One #10-4 AWG or Two #12-2 AWG per terminal.
                                                        solid cable: One #10-3 AWG or Two #10-6 AWG per terminal.

                                                        What is the difference between the LAD4TB and LAD4TBDL bi-directional peak limiting diode?

                                                        Issue:
                                                        Identifying the difference between LAD4TB and LAD4TBDL

                                                        Product Line:
                                                        IEC contactors and starters

                                                        Environment:
                                                        Products sold and used in the United States

                                                        Cause:
                                                        Identifying the difference between two similar part numbers

                                                        Resolution:
                                                        The LAD4TB is for 24V AC coils for the Tesys Series LC1D09 through LC1D38 contactors when supplied with G7 voltage code. The LAD4TBDL is 24 vdc bi-directional diode offered as a replacement if for some reason the diode supplied with the Tesys LC1D09 through LC1D38 contactors when ordered with BD or BL voltage code breaks or is no longer working.


                                                         

                                                        What replaces a LC1D18M7

                                                        Use the LC1D18U7

                                                        Video: What auxiliary contact modules are available for the LC1D and LC2D contactors?

                                                        Issue:
                                                        Auxiliary contact modules for the LC1D and LC2D contactors

                                                        Product Line: 
                                                        Contactor and Starters - IEC

                                                        Environment:
                                                        North American Products

                                                        Resolution:
                                                        Select based on application requirements. Please note that the TeSys and Pre-TeSys auxiliary blocks are backward/forward compatible.
                                                        Front Mounting; maximum of 1 block per contactor:

                                                        N.O.-------N.C.-----TeSys P/N--------Pre-TeSys P/N
                                                        --1-----------1---------LADN11-----------LA1DN11
                                                        --1-----------1---------LADN11G---------LA1DN11G (See Footnote 1)
                                                        --1-----------1---------LADN11P---------LA1DN11P (See Footnote 1)
                                                        --2-----------0---------LADN20-----------LA1DN20
                                                        --2-----------0---------LA1DX20---------LA1DX20 (See Footnote 2)
                                                        --2-----------0---------LA1DY20---------LA1DY20 (See Footnote 3)
                                                        --0-----------2---------LADN02-----------LA1DN02
                                                        --2-----------2---------LADN22-----------LA1DN22
                                                        --2-----------2---------LADN22G---------LA1DN22G (See Footnote 1)
                                                        --2-----------2---------LADN22P---------LA1DN22P (See Footnote 1)
                                                        --2-----------2---------LADC22------------LA1DC22 (See Footnote 4)
                                                        --3-----------1---------LADN31------------LA1DN31
                                                        --3-----------1---------LA1DZ31----------LA1DZ31 (See Footnote 5)
                                                        --1-----------3---------LADN13------------LA1DN13
                                                        --4-----------0---------LADN40------------LA1DN40
                                                        --4-----------0---------LA1DZ40-----------LA1DZ40 (See Footnote 6)
                                                        --0-----------4---------LADN04------------LA1DN04




                                                        Front Mounting; maximum of 1 block per contactor: For use with D2 Series 25 amp through 80 amp contactors and TeSys Series 40 amp through 80 amp only.

                                                        N.O.-------N.C.-----TeSys P/N--------Pre-TeSys P/N
                                                        --1-----------0--------LADN10----------LA1DN10
                                                        --0-----------1--------LADN01----------LA1DN01

                                                        Side Mounting; maximum of 1 block on each side for D2 Series and Tesys Series 40 through 80 amp contactors. Tesys 9 through 32, 115, and 150 amps contactors will accept 1 block and is limited to left side only. (*) DC control devices will not accept side mount auxiliaries.
                                                        (*) DC control exceptions that will accept one left side mounted auxiliary: LC1D115 & LC1D150.

                                                        N.O.-------N.C.-----TeSys P/N--------Pre-TeSys P/N
                                                        --1-----------1--------LAD8N11----------LA8DN11
                                                        --2-----------0--------LAD8N20----------LA8DN20
                                                        --0-----------2--------LAD8N02----------N/A

                                                        Footnotes:
                                                        {1} EN50 012 Machine Tool Terminal Markings
                                                        {2} (2) NO Sealed Dust Tight Contacts
                                                        {3} Gold Flash Contacts
                                                        {4} (1) NO & (1) NC Standard and (1) NO & (1) NC Make Before Break
                                                        {5} (2) NO Dust Tight Contacts & (1) NO & (1) NC Standard Contacts
                                                        {6} (2) NO Dust Tight Contacts & (2) NO Standard Contacts
                                                        Show More