LC1D115gp TeSys
CONTACTOR 115A 1F+1O 110V50 60 3P+1O+1F
LC1D115gp TeSys
CONTACTOR 115A 1F+1O 110V50 60 3P+1O+1F

TeSys D Contactor, 3P(3 NO), AC-3, <= 440V, 115A, 415VAC, 50 Hz Coil

Catalogue Number: LC1D1156N5
LC1D115gp TeSys
CONTACTOR 115A 1F+1O 110V50 60 3P+1O+1F
LC1D115gp TeSys
CONTACTOR 115A 1F+1O 110V50 60 3P+1O+1F
Retail
$2,934.09
RRP (Inc. GST)

Specifications

hide show
Range of product
TeSys D
Range
TeSys
Product name
TeSys D
Product or component type
contactor
Device short name
LC1D
Contactor application
  • resistive load
  • motor control
    • Utilisation category
    • AC-3
    • AC-1
    • AC-4
      • Poles description
        3P
        Pole contact composition
        3 NO
        [Ue] rated operational voltage
      • power circuit: <= 1000 V AC 25...400 Hz
      • power circuit: <= 300 V DC
        • [Ie] rated operational current
        • 200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
        • 115 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
          • Motor power kW
          • 30 kW at 220...230 V AC 50/60 Hz (AC-3)
          • 55 kW at 380...400 V AC 50/60 Hz (AC-3)
          • 59 kW at 415...440 V AC 50/60 Hz (AC-3)
          • 75 kW at 500 V AC 50/60 Hz (AC-3)
          • 80 kW at 660...690 V AC 50/60 Hz (AC-3)
          • 65 kW at 1000 V AC 50/60 Hz (AC-3)
          • 18.5 kW at 400 V AC 50/60 Hz (AC-4)
            • Motor power hp
            • 30 hp at 200/208 V AC 50/60 Hz for 3 phases motors
            • 40 hp at 230/240 V AC 50/60 Hz for 3 phases motors
            • 75 hp at 460/480 V AC 50/60 Hz for 3 phases motors
            • 100 hp at 575/600 V AC 50/60 Hz for 3 phases motors
              • Control circuit type
                AC at 50 Hz
                [Uc] control circuit voltage
                415 V AC 50 Hz
                Auxiliary contact composition
                1 NO + 1 NC
                [Uimp] rated impulse withstand voltage
                8 kV conforming to IEC 60947
                Overvoltage category
                III
                [Ith] conventional free air thermal current
                200 A (at 60 °C) for power circuit
                Irms rated making capacity
              • 1260 A at 440 V for power circuit conforming to IEC 60947
              • 140 A AC for signalling circuit conforming to IEC 60947-5-1
              • 250 A DC for signalling circuit conforming to IEC 60947-5-1
                • Rated breaking capacity
                  1100 A at 440 V for power circuit conforming to IEC 60947
                  [Icw] rated short-time withstand current
                • 250 A 40 °C - 10 min for power circuit
                • 550 A 40 °C - 1 min for power circuit
                • 950 A 40 °C - 10 s for power circuit
                • 1100 A 40 °C - 1 s for power circuit
                • 100 A - 1 s for signalling circuit
                • 120 A - 500 ms for signalling circuit
                • 140 A - 100 ms for signalling circuit
                  • Associated fuse rating
                  • 250 A gG at <= 690 V coordination type 1 for power circuit
                  • 200 A gG at <= 690 V coordination type 2 for power circuit
                  • 10 A gG for signalling circuit
                    • Average impedance
                      0.6 mOhm - Ith 200 A 50 Hz for power circuit
                      [Ui] rated insulation voltage
                    • power circuit: 600 V CSA certified
                    • power circuit: 600 V UL certified
                    • power circuit: 1000 V conforming to IEC 60947-4-1
                    • signalling circuit: 690 V conforming to IEC 60947-1
                    • signalling circuit: 600 V CSA certified
                    • signalling circuit: 600 V UL certified
                      • Electrical durability
                      • 0.8 Mcycles 200 A AC-1 at Ue <= 440 V
                      • 0.95 Mcycles 115 A AC-3 at Ue <= 440 V
                        • Power dissipation per pole
                        • 24 W AC-1
                        • 7.9 W AC-3
                          • Protective cover
                            with
                            Mounting support
                          • rail
                          • plate
                            • Standards
                            • CSA C22.2 No 14
                            • EN 60947-4-1
                            • EN 60947-5-1
                            • IEC 60947-4-1
                            • IEC 60947-5-1
                            • UL 508
                              • Product certifications
                              • UL
                              • CSA
                              • BV
                              • RINA
                              • CCC
                              • LROS (Lloyds register of shipping)
                              • GL
                              • GOST
                              • DNV
                                • Connections - terminals
                                • control circuit: lugs-ring terminals (external diameter: 8 mm)
                                • power circuit: lugs-ring terminals (external diameter: 25 mm)
                                • power circuit: bars 1 cable(s) - busbar cross section: 5 x 25 mm
                                  • Tightening torque
                                  • control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver flat Ø 6 mm M3.5
                                  • control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver Philips No 2 M3.5
                                  • power circuit: 12 N.m - on lugs-ring terminals hexagonal screw head 13 mm M8
                                  • power circuit: 12 N.m - on bars hexagonal screw head 13 mm M8
                                    • Operating time
                                    • 6...20 ms opening
                                    • 20...50 ms closing
                                      • Safety reliability level
                                      • B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
                                      • B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
                                        • Mechanical durability
                                          8 Mcycles
                                          Maximum operating rate
                                          2400 cyc/h 60 °C
                                          Coil technology
                                          without built-in suppressor module
                                          Inrush power in VA
                                          300-300 VA 50 Hz cos phi 0.8 (at 20 °C)
                                          Hold-in power consumption in VA
                                          22-22 VA 50 Hz cos phi 0.3 (at 20 °C)
                                          Heat dissipation
                                          3-8 W at 50 Hz
                                          Auxiliary contacts type
                                        • type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
                                        • type mirror contact 1 NC conforming to IEC 60947-4-1
                                          • Signalling circuit frequency
                                            25...400 Hz
                                            Minimum switching current
                                            5 mA for signalling circuit
                                            Minimum switching voltage
                                            17 V for signalling circuit
                                            Non-overlap time
                                          • 1.5 ms on de-energisation between NC and NO contact
                                          • 1.5 ms on energisation between NC and NO contact
                                            • Insulation resistance
                                              > 10 MOhm for signalling circuit
                                              Contact compatibility
                                              M13
                                              Compatibility code
                                              LC1D
                                              IP degree of protection
                                              IP20 front face conforming to IEC 60529
                                              Protective treatment
                                              TH conforming to IEC 60068-2-30
                                              Pollution degree
                                              3
                                              Ambient air temperature for storage
                                              -60-80 °C
                                              Operating altitude
                                              3000 m without derating
                                              Fire resistance
                                              850 °C conforming to IEC 60695-2-1
                                              Flame retardance
                                              V1 conforming to UL 94
                                              Mechanical robustness
                                            • vibrations contactor open: 2 Gn, 5...300 Hz
                                            • vibrations contactor closed: 4 Gn, 5...300 Hz
                                            • shocks contactor closed: 15 Gn for 11 ms
                                            • shocks contactor open: 6 Gn for 11 ms
                                              • Height
                                                158 mm
                                                Width
                                                120 mm
                                                Depth
                                                136 mm
                                                Net weight
                                                2.5 kg
                                                Unit Type of Package 1
                                                PCE
                                                Number of Units in Package 1
                                                1
                                                Package 1 Weight
                                                2.11 kg
                                                Package 1 Height
                                                16.8 cm
                                                Package 1 width
                                                20.8 cm
                                                Package 1 Length
                                                18.5 cm
                                                Sustainable offer status
                                                Green Premium product
                                                EU RoHS Directive
                                                Compliant
                                                Mercury free
                                                Yes
                                                RoHS exemption information
                                                Yes
                                                China RoHS Regulation
                                                Product out of China RoHS scope. Substance declaration for your information
                                                Environmental Disclosure
                                                ENVPEP060301EN
                                                Circularity Profile
                                                ENVEOLI100405EN
                                                WEEE
                                                The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                                                PVC free
                                                Yes
                                                Warranty
                                                18 months

                                                Documents & downloads

                                                hide show
                                                Filter items
                                                • All

                                                • CAD Files and Packs

                                                • Product Brochures

                                                • End of Life Manual

                                                • Installation Instruction

                                                • Product Environmental

                                                • Certificates (MSDS)

                                                • Declaration of Conformity

                                                Frequently Asked Questions

                                                hide show

                                                What is the maximum UL/CSA AC voltage rating of the LC1D power contacts ?

                                                Issue:
                                                Identifying maximum voltage of an LC1D contactor

                                                Product Line:
                                                TeSys D Contactors

                                                Environment:
                                                IEC contactors and starters used in North America

                                                Cause:
                                                n/a

                                                Resolution:
                                                IThe maximum voltage per UL and CSA is 600VAC. 
                                                 

                                                What is the difference between LC1D115 and LC1D1156?

                                                The 6 in LC1D1156.. is that the 6 denotes lug bar terminals. Use LC1D115.. for cable connections.


                                                 

                                                What is the difference between the LC1D1506N7 and the LC1D150N7?

                                                The LC1D1506N7 can accept 5X25mm Bars aswell as Lugs or ring terminals. The LC1D150N7 only accepts cable lugs upto 120mm2.

                                                What is the terminal shroud part number for a LC1D1156**

                                                The part code is LA9D115703

                                                Does the LC1D1156U7 come with 1NO & 1NC Aux contact

                                                Yes - all the D range contactors have one of each aux contact

                                                What is the part number for the 415V AC Coil for the LC1D1156 Contactor?

                                                The part number for the 415V AC Coil for the LC1D1156 Contactor is "LX1D8N7"

                                                https://www.schneider-electric.com.au/en/search/lx1d8n7


                                                 

                                                What are the coil voltage codes for the LC1D115 / LC2D115 and LC1D150 / LC2D150 TeSys contactor?

                                                Issue:
                                                LC1D115 / LC2D115 and LC1D150 / LC2D150

                                                Product Line:
                                                Tesys D line Contactors

                                                Environment:
                                                North America

                                                Resolution:
                                                The following list the more common voltage suffix codes for these product lines.  For a more comprehensive list and to determine compatibility with a given product, refer to the catalog below.

                                                Note 1: LC1D150 contactors are only available with *7 coil codes.
                                                Note 2: Coil Code ending number represents frequency rating as follows:
                                                5 = 50 Hertz
                                                6 = 60 Hertz
                                                7 = 50/60 Hertz

                                                AC Volts ___Code                DC Volts ___Code
                                                24 ___ B5 or B6 or B7          12 ___ Not Avail.        
                                                42 ___ D5 or D7                   24 ___ BD
                                                48 ___ E5 or E6 or E7          36 ___ CD
                                                110 ___ F5 or F6 or F7         48 ___ ED
                                                115 ___ FE5 or FE7             60 ___ ND
                                                120 ___ G6 or G7                72 ___ SD
                                                127 ___ FC5 or FC7            110 ___ FD
                                                208 ___ L6 or LE7               125 ___ GD
                                                220 ___ M5 or M6 or M7       220 ___ MD
                                                230 ___ P5 or P7                 250 ___ UD
                                                240 ___ U5 or U6 or U7        440 ___ RD
                                                277 ___ W6 or UE7                
                                                380 ___ Q5 or Q6 or Q7                
                                                400 ___ V5 or V7                
                                                415 ___ N5 or N7                
                                                440 ___ R5 or R6 or R7                
                                                480 ___ T6 or T7                
                                                500 ___ S5 or S7                


                                                 

                                                What is the interlock to use with the lcd1156**

                                                 The interlock is LA9D11502

                                                Are the D-Line contactors rated to break DC voltages?

                                                Issue: 
                                                Can the TeSys D line be used to control DC loads? 

                                                Product Line:
                                                Tesys D contactors

                                                Environment:
                                                Products sold and used in the United States
                                                 
                                                Cause:
                                                 DC power circuit
                                                 
                                                Resolution:
                                                 
                                                Yes, 75 VDC (125 VDC for D115 & D150) per pole which means that through a four pole device breaking 300 VDC is possible by wiring all four power poles in series. However, be aware that the device current ratings will differ according to the number of poles in series and the type of application.

                                                Devices are suitable but not UL Listed for DC applications.

                                                More information on their DC ratings can be found in the current TeSys Motor Control and Protection Compentns catalog: https://www.schneider-electric.us/en/download/document/MKTED210011EN/


                                                 

                                                What is the code for a contactor rated at 100A AC3 with a 240V AC coil ?

                                                Code = LC1D1156U7 ( 3 Pole Contactor comes with 1 N/C + 1 N/O Auxilliary as a standard ) 

                                                What is the difference between LA9D11569 and LA9D115691?

                                                Issue:
                                                Identifying differences between two part numbers

                                                Product Line:
                                                IEC contactors and starters

                                                Environment:
                                                Products sold and used in the United States

                                                Cause:
                                                Selecting between two similar part numbers

                                                Resolution:
                                                LA9D11569 is a set of power connections. LA9D115691 is the bottom connector only as shown on page 16-9 of Digest 173 for the LC1D115 and LC1D150 contactor.


                                                 

                                                What is the 85A Overload to suit LC1D115* Contactor

                                                85A Overload code for LC1D115* Contactor = LRD4365 
                                                Show More