LC1D115gp TeSys
CONTACTOR
LC1D115gp TeSys
CONTACTOR

TeSys D Contactor, 3P(3 NO), AC-3, <= 440V, 115A, 220VAC, 50/60 Hz Coil

Catalogue Number: LC1D1156M7
LC1D115gp TeSys
CONTACTOR
LC1D115gp TeSys
CONTACTOR
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Range of product
TeSys D
Range
TeSys
Product name
TeSys D
Product or component type
contactor
Device short name
LC1D
Contactor application
  • motor control
  • resistive load
    • Utilisation category
    • AC-3
    • AC-4
    • AC-1
      • Poles description
        3P
        Pole contact composition
        3 NO
        [Ue] rated operational voltage
      • power circuit: <= 1000 V AC 25...400 Hz
      • power circuit: <= 300 V DC
        • [Ie] rated operational current
        • 200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
        • 115 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
          • Motor power kW
          • 30 kW at 220...230 V AC 50/60 Hz (AC-3)
          • 55 kW at 380...400 V AC 50/60 Hz (AC-3)
          • 59 kW at 415...440 V AC 50/60 Hz (AC-3)
          • 75 kW at 500 V AC 50/60 Hz (AC-3)
          • 80 kW at 660...690 V AC 50/60 Hz (AC-3)
          • 65 kW at 1000 V AC 50/60 Hz (AC-3)
          • 18.5 kW at 400 V AC 50/60 Hz (AC-4)
            • Motor power hp
            • 30 hp at 200/208 V AC 50/60 Hz for 3 phases motors
            • 40 hp at 230/240 V AC 50/60 Hz for 3 phases motors
            • 75 hp at 460/480 V AC 50/60 Hz for 3 phases motors
            • 100 hp at 575/600 V AC 50/60 Hz for 3 phases motors
              • Control circuit type
                AC at 50/60 Hz
                [Uc] control circuit voltage
                220 V AC 50/60 Hz
                Auxiliary contact composition
                1 NO + 1 NC
                [Uimp] rated impulse withstand voltage
                8 kV conforming to IEC 60947
                Overvoltage category
                III
                [Ith] conventional free air thermal current
                200 A (at 60 °C) for power circuit
                Irms rated making capacity
              • 1260 A at 440 V for power circuit conforming to IEC 60947
              • 140 A AC for signalling circuit conforming to IEC 60947-5-1
              • 250 A DC for signalling circuit conforming to IEC 60947-5-1
                • Rated breaking capacity
                  1100 A at 440 V for power circuit conforming to IEC 60947
                  [Icw] rated short-time withstand current
                • 250 A 40 °C - 10 min for power circuit
                • 550 A 40 °C - 1 min for power circuit
                • 950 A 40 °C - 10 s for power circuit
                • 1100 A 40 °C - 1 s for power circuit
                • 100 A - 1 s for signalling circuit
                • 120 A - 500 ms for signalling circuit
                • 140 A - 100 ms for signalling circuit
                  • Associated fuse rating
                  • 250 A gG at <= 690 V coordination type 1 for power circuit
                  • 200 A gG at <= 690 V coordination type 2 for power circuit
                  • 10 A gG for signalling circuit
                    • Average impedance
                      0.6 mOhm - Ith 200 A 50 Hz for power circuit
                      [Ui] rated insulation voltage
                    • power circuit: 600 V CSA certified
                    • power circuit: 600 V UL certified
                    • power circuit: 1000 V conforming to IEC 60947-4-1
                    • signalling circuit: 690 V conforming to IEC 60947-1
                    • signalling circuit: 600 V CSA certified
                    • signalling circuit: 600 V UL certified
                      • Electrical durability
                      • 0.8 Mcycles 200 A AC-1 at Ue <= 440 V
                      • 0.95 Mcycles 115 A AC-3 at Ue <= 440 V
                        • Power dissipation per pole
                        • 24 W AC-1
                        • 7.9 W AC-3
                          • Protective cover
                            with
                            Mounting support
                          • plate
                          • rail
                            • Standards
                            • CSA C22.2 No 14
                            • EN 60947-4-1
                            • EN 60947-5-1
                            • IEC 60947-4-1
                            • IEC 60947-5-1
                            • UL 508
                              • Product certifications
                              • CSA
                              • CCC
                              • RINA
                              • GOST
                              • UL
                              • DNV
                              • GL
                              • LROS (Lloyds register of shipping)
                              • BV
                                • Connections - terminals
                                • control circuit: lugs-ring terminals (external diameter: 8 mm)
                                • power circuit: lugs-ring terminals (external diameter: 25 mm)
                                • power circuit: bars 1 cable(s) - busbar cross section: 5 x 25 mm
                                  • Tightening torque
                                  • control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver flat Ø 6 mm M3.5
                                  • control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver Philips No 2 M3.5
                                  • power circuit: 12 N.m - on lugs-ring terminals hexagonal screw head 13 mm M8
                                  • power circuit: 12 N.m - on bars hexagonal screw head 13 mm M8
                                    • Operating time
                                    • 6...20 ms opening
                                    • 20...50 ms closing
                                      • Safety reliability level
                                      • B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
                                      • B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
                                        • Mechanical durability
                                          8 Mcycles
                                          Maximum operating rate
                                          2400 cyc/h 60 °C
                                          Coil technology
                                          built-in bidirectional peak limiting diode suppressor
                                          Control circuit voltage limits
                                        • drop-out: 0.3...0.5 Uc AC 50/60 Hz (at 55 °C)
                                        • operational: 0.8...1.15 Uc AC 50/60 Hz (at 55 °C)
                                          • Inrush power in VA
                                          • 280-350 VA 60 Hz cos phi 0.8 (at 20 °C)
                                          • 280-350 VA 50 Hz cos phi 0.8 (at 20 °C)
                                            • Hold-in power consumption in VA
                                            • 2-18 VA 60 Hz cos phi 0.3 (at 20 °C)
                                            • 2-18 VA 50 Hz cos phi 0.3 (at 20 °C)
                                              • Heat dissipation
                                                3-8 W at 50/60 Hz
                                                Auxiliary contacts type
                                              • type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
                                              • type mirror contact 1 NC conforming to IEC 60947-4-1
                                                • Signalling circuit frequency
                                                  25...400 Hz
                                                  Minimum switching current
                                                  5 mA for signalling circuit
                                                  Minimum switching voltage
                                                  17 V for signalling circuit
                                                  Non-overlap time
                                                • 1.5 ms on de-energisation between NC and NO contact
                                                • 1.5 ms on energisation between NC and NO contact
                                                  • Insulation resistance
                                                    > 10 MOhm for signalling circuit
                                                    Contact compatibility
                                                    M13
                                                    Compatibility code
                                                    LC1D
                                                    IP degree of protection
                                                    IP20 front face conforming to IEC 60529
                                                    Protective treatment
                                                    TH conforming to IEC 60068-2-30
                                                    Pollution degree
                                                    3
                                                    Ambient air temperature for operation
                                                    -5-60 °C
                                                    Ambient air temperature for storage
                                                    -60-80 °C
                                                    Permissible ambient air temperature around the device
                                                    -40-70 °C at Uc
                                                    Operating altitude
                                                    3000 m without
                                                    Fire resistance
                                                    850 °C conforming to IEC 60695-2-1
                                                    Flame retardance
                                                    V1 conforming to UL 94
                                                    Mechanical robustness
                                                  • vibrations contactor open: 2 Gn, 5...300 Hz
                                                  • vibrations contactor closed: 4 Gn, 5...300 Hz
                                                  • shocks contactor closed: 15 Gn for 11 ms
                                                  • shocks contactor open: 6 Gn for 11 ms
                                                    • Height
                                                      158 mm
                                                      Width
                                                      120 mm
                                                      Depth
                                                      136 mm
                                                      Net weight
                                                      2.5 kg
                                                      Sustainable offer status
                                                      Green Premium product
                                                      REACh Regulation
                                                      Free of Substances of Very High Concern above the threshold
                                                      EU RoHS Directive
                                                      Compliant
                                                      Mercury free
                                                      Yes
                                                      RoHS exemption information
                                                      Yes
                                                      China RoHS Regulation
                                                      Product out of China RoHS scope. Substance declaration for your information
                                                      Environmental Disclosure
                                                      ENVPEP060301EN
                                                      Circularity Profile
                                                      ENVEOLI100405
                                                      WEEE
                                                      The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                                                      California proposition 65
                                                      WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.gov
                                                      Warranty
                                                      18 months

                                                      Documents & downloads

                                                      hide show
                                                      Filter items
                                                      • All

                                                      • CAD Files and Packs

                                                      • Product Brochures

                                                      • Technical Data Catalogues

                                                      • End of Life Manual

                                                      • Installation Instruction

                                                      • Data Bulletin

                                                      • Product Environmental

                                                      • Certificates (MSDS)

                                                      • Declaration of Conformity

                                                      Frequently Asked Questions

                                                      hide show

                                                      What is the maximum UL/CSA AC voltage rating of the LC1D power contacts ?

                                                      Issue:
                                                      Identifying maximum voltage of an LC1D contactor

                                                      Product Line:
                                                      TeSys D Contactors

                                                      Environment:
                                                      IEC contactors and starters used in North America

                                                      Cause:
                                                      n/a

                                                      Resolution:
                                                      IThe maximum voltage per UL and CSA is 600VAC. 
                                                       

                                                      Where are the control coil terminals for TeSys LC1D09 to LC1D38 contactor?

                                                      Issue:
                                                      Determine the control coil terminal marking and location on LC1D09 to LC1D38 contactor

                                                      Product Line: 
                                                      Tesys D Contactors

                                                      Environment:
                                                      IEC contactors

                                                      Resolution:
                                                      The coil terminals are marked A1 and A2, you can see them on the front of the contactor on the white part (control section).  They are next to the auxiliary contact (13/14, 21/22) terminals.
                                                       

                                                      What is the replacement coil part number for the LC*D09 through LC*D32 and LC*DT20 through LC*DT40 TeSys contactors?

                                                      Issue:
                                                      Identifying replacement coils for tesys D non-reversing and reversing conactors

                                                      Product Line:
                                                      IEC Contactors and Starters

                                                      Environment:
                                                      Products sold and used in the United States

                                                      Cause:
                                                      Replacement coil is needed

                                                      Resolution:
                                                      DC replacement coils are not available.
                                                      AC Coils are 50/60 hertz for voltages as listed below:

                                                      Volts - Part Number
                                                      12 ____ LXD1J7
                                                      21 ____ LXD1Z7
                                                      24 ____ LXD1B7
                                                      32 ____ LXD1C7
                                                      36 ____ LXD1CC7
                                                      42 ____ LXD1D7
                                                      48 ____ LXD1E7
                                                      60 ____ LXD1EE7
                                                      100 ___ LXD1K7 ( never brought to North America )
                                                      110 ___ LXD1F7
                                                      115 ___ LXD1FE7
                                                      120 ___ LXD1G7
                                                      127 ___ LXD1FC7
                                                      200 ___ LXD1L7
                                                      208 ___ LXD1LE7
                                                      220 ___ LXD1M7
                                                      230 ___ LXD1P7
                                                      240 ___ LXD1U7
                                                      277 ___ LXD1W7
                                                      380 ___ LXD1Q7
                                                      400 ___ LXD1V7
                                                      415 ___ LXD1N7
                                                      440 ___ LXD1R7
                                                      480 ___ LXD1T7
                                                      575 ___ LXD1SC7
                                                      600 ___ LXD1X7
                                                      690 ___ LXD1Y7


                                                      Note: A contactor with an AC coil can be changed to a different AC voltage coil, IE you can take an LC1D09 with a 120VAC coil and put a 24VAC coil in it instead. An AC device cannot be switched to a DC coil, and a DC device cannot be switches to an AC coil. 

                                                      What is the difference between LC1D115 and LC1D1156?

                                                      The 6 in LC1D1156.. is that the 6 denotes lug bar terminals. Use LC1D115.. for cable connections.


                                                       

                                                      What is the difference between the LC1D1506N7 and the LC1D150N7?

                                                      The LC1D1506N7 can accept 5X25mm Bars aswell as Lugs or ring terminals. The LC1D150N7 only accepts cable lugs upto 120mm2.

                                                      Does the LC1D1156U7 come with 1NO & 1NC Aux contact

                                                      Yes - all the D range contactors have one of each aux contact

                                                      What is the terminal shroud part number for a LC1D1156**

                                                      The part code is LA9D115703

                                                      What is the power terminal lug data for the LC1D09, LC1DT20, LC1D12, and LC1DT25 contactor?

                                                      Issue:
                                                      Power terminal lug data required for the 9 and 12 amp rated Tesys D contactors

                                                      Product Line:
                                                      NEMA combination starters

                                                      Environment:
                                                      Products sold and used in the United States

                                                      Resolution:
                                                      For contactors with screw clamp terminals:
                                                      stranded cable w/o cable end : One or Two #18-10 AWG per terminal.
                                                      stranded cable w/cable end: One or Two #18-10 AWG per terminal.
                                                      solid cable: One or Two #18-8 AWG per terminal.

                                                      What is the code for a contactor rated at 100A AC3 with a 240V AC coil ?

                                                      Code = LC1D1156U7 ( 3 Pole Contactor comes with 1 N/C + 1 N/O Auxilliary as a standard ) 

                                                      What is the part number for the 415V AC Coil for the LC1D1156 Contactor?

                                                      The part number for the 415V AC Coil for the LC1D1156 Contactor is "LX1D8N7"

                                                      https://www.schneider-electric.com.au/en/search/lx1d8n7


                                                       

                                                      What is the interlock to use with the lcd1156**

                                                       The interlock is LA9D11502

                                                      Are the D-Line contactors rated to break DC voltages?

                                                      Issue: 
                                                      Can the TeSys D line be used to control DC loads? 

                                                      Product Line:
                                                      Tesys D contactors

                                                      Environment:
                                                      Products sold and used in the United States
                                                       
                                                      Cause:
                                                       DC power circuit
                                                       
                                                      Resolution:
                                                       
                                                      Yes, 75 VDC (125 VDC for D115 & D150) per pole which means that through a four pole device breaking 300 VDC is possible by wiring all four power poles in series. However, be aware that the device current ratings will differ according to the number of poles in series and the type of application.

                                                      Devices are suitable but not UL Listed for DC applications.

                                                      More information on their DC ratings can be found in the current TeSys Motor Control and Protection Compentns catalog: https://www.schneider-electric.us/en/download/document/MKTED210011EN/


                                                       

                                                      What are the coil voltage codes for the LC1D115 / LC2D115 and LC1D150 / LC2D150 TeSys contactor?

                                                      Issue:
                                                      LC1D115 / LC2D115 and LC1D150 / LC2D150

                                                      Product Line:
                                                      Tesys D line Contactors

                                                      Environment:
                                                      North America

                                                      Resolution:
                                                      The following list the more common voltage suffix codes for these product lines.  For a more comprehensive list and to determine compatibility with a given product, refer to the catalog below.

                                                      Note 1: LC1D150 contactors are only available with *7 coil codes.
                                                      Note 2: Coil Code ending number represents frequency rating as follows:
                                                      5 = 50 Hertz
                                                      6 = 60 Hertz
                                                      7 = 50/60 Hertz

                                                      AC Volts ___Code                DC Volts ___Code
                                                      24 ___ B5 or B6 or B7          12 ___ Not Avail.        
                                                      42 ___ D5 or D7                   24 ___ BD
                                                      48 ___ E5 or E6 or E7          36 ___ CD
                                                      110 ___ F5 or F6 or F7         48 ___ ED
                                                      115 ___ FE5 or FE7             60 ___ ND
                                                      120 ___ G6 or G7                72 ___ SD
                                                      127 ___ FC5 or FC7            110 ___ FD
                                                      208 ___ L6 or LE7               125 ___ GD
                                                      220 ___ M5 or M6 or M7       220 ___ MD
                                                      230 ___ P5 or P7                 250 ___ UD
                                                      240 ___ U5 or U6 or U7        440 ___ RD
                                                      277 ___ W6 or UE7                
                                                      380 ___ Q5 or Q6 or Q7                
                                                      400 ___ V5 or V7                
                                                      415 ___ N5 or N7                
                                                      440 ___ R5 or R6 or R7                
                                                      480 ___ T6 or T7                
                                                      500 ___ S5 or S7                


                                                       

                                                      What is the difference between LA9D11569 and LA9D115691?

                                                      Issue:
                                                      Identifying differences between two part numbers

                                                      Product Line:
                                                      IEC contactors and starters

                                                      Environment:
                                                      Products sold and used in the United States

                                                      Cause:
                                                      Selecting between two similar part numbers

                                                      Resolution:
                                                      LA9D11569 is a set of power connections. LA9D115691 is the bottom connector only as shown on page 16-9 of Digest 173 for the LC1D115 and LC1D150 contactor.


                                                       

                                                      What is the altitude derating for a TeSys D-Line contactor?

                                                      Issue:​
                                                      What is the altitude derating for a TeSys D-Line contactor?

                                                      Product Line:
                                                      Digest 177 Section 18 : Contactors and Starters, IEC

                                                      Environment:
                                                      North American Products

                                                      Resolution:
                                                      The contactors are fully rated up to 3000 meters. Following are derating multipliers for altitudes above 3000 meters for both voltage and current:

                                                      Voltage
                                                      3500m x 0.90
                                                      4000m x 0.80
                                                      4500m x 0.70
                                                      5000m x 0.60

                                                      Current
                                                      3500m x 0.92
                                                      4000m x 0.90
                                                      4500m x 0.88
                                                      5000m x 0.86

                                                      For example, an LC1D80 at 5000 meters:
                                                      - The maximum rated operational voltage is 1,000V (IEC947-4) and 690V (UL/CSA). At 5000 meters it becomes 1000V x 0.6 = 600V (IEC947-4) and 690V x 0.6 = 414V (UL/CSA).
                                                      - The maximum rated operational AC3 current is 80A. At 5000 meters it becomes 80A x 0.86 = 68A.



                                                       

                                                      What is the 85A Overload to suit LC1D115* Contactor

                                                      85A Overload code for LC1D115* Contactor = LRD4365 

                                                      What replaces a LC1D18M7

                                                      Use the LC1D18U7

                                                      What is part number for terminal shrouds for LC1D1506U7?

                                                      The part number for terminal shrouds for LC1D1506 and LC1D1156 contactors is LA9D115703
                                                      User-added image

                                                      LA9D115703

                                                      Shrouds - for 3 poles TeSys model D

                                                      For furher information see:
                                                      https://www.schneider-electric.com.au/en/product/LA9D115703/shrouds---for-3-poles-tesys-model-d

                                                       

                                                      Are replacement contacts available for LC1D115?

                                                      Issue:
                                                      Replacement contacts needed for 115 amp D line contactor

                                                      Product Line:
                                                      IEC contactors and starters

                                                      Environment:
                                                      Products sold and used in the United States

                                                      Cause:
                                                      Identifying part number to order replacement contact kit

                                                      Resolution:
                                                      Yes, order LA5D1158031 for 3 pole kit or LA5D115804 for 4 pole kit.


                                                      CTA-ID : 11125

                                                      What code is a mechanical interlock for the 4pole LC1D1150046 contactor?

                                                      LA9D11502 will fit the 4p LC1D115 and LC1D150 contactors

                                                      What replaces the LC1D12004M7 contactor?

                                                      Will the LAD** time delay auxiliary contact module fit the D2 series pre-Tesys contactors?

                                                      Issue:
                                                      Can new accessories be used on older style contactors

                                                      Product Line:
                                                      IEC contactors and starters

                                                      Environment:
                                                      Products sold and used in the United States

                                                      Cause:
                                                      Identifying product compatibility

                                                      Resolution:
                                                      Yes, all front mount D2 and Tesys series auxiliary modules are backward forward compatible.


                                                       

                                                      What is the color scheme of the Tesys D-Line contactors?

                                                      Issue:
                                                      Looking for different color scheme of the Tesys D-Line contactors.

                                                      Product Line:
                                                      Tesys D Contactors

                                                      Environment:
                                                      LC1D contactors

                                                      Resolution:
                                                      Beige and dark gray.
                                                       

                                                      Video: What auxiliary contact modules are available for the LC1D and LC2D contactors?

                                                      Issue:
                                                      Auxiliary contact modules for the LC1D and LC2D contactors

                                                      Product Line: 
                                                      Contactor and Starters - IEC

                                                      Environment:
                                                      North American Products

                                                      Resolution:
                                                      Select based on application requirements. Please note that the TeSys and Pre-TeSys auxiliary blocks are backward/forward compatible.
                                                      Front Mounting; maximum of 1 block per contactor:

                                                      N.O.-------N.C.-----TeSys P/N--------Pre-TeSys P/N
                                                      --1-----------1---------LADN11-----------LA1DN11
                                                      --1-----------1---------LADN11G---------LA1DN11G (See Footnote 1)
                                                      --1-----------1---------LADN11P---------LA1DN11P (See Footnote 1)
                                                      --2-----------0---------LADN20-----------LA1DN20
                                                      --2-----------0---------LA1DX20---------LA1DX20 (See Footnote 2)
                                                      --2-----------0---------LA1DY20---------LA1DY20 (See Footnote 3)
                                                      --0-----------2---------LADN02-----------LA1DN02
                                                      --2-----------2---------LADN22-----------LA1DN22
                                                      --2-----------2---------LADN22G---------LA1DN22G (See Footnote 1)
                                                      --2-----------2---------LADN22P---------LA1DN22P (See Footnote 1)
                                                      --2-----------2---------LADC22------------LA1DC22 (See Footnote 4)
                                                      --3-----------1---------LADN31------------LA1DN31
                                                      --3-----------1---------LA1DZ31----------LA1DZ31 (See Footnote 5)
                                                      --1-----------3---------LADN13------------LA1DN13
                                                      --4-----------0---------LADN40------------LA1DN40
                                                      --4-----------0---------LA1DZ40-----------LA1DZ40 (See Footnote 6)
                                                      --0-----------4---------LADN04------------LA1DN04




                                                      Front Mounting; maximum of 1 block per contactor: For use with D2 Series 25 amp through 80 amp contactors and TeSys Series 40 amp through 80 amp only.

                                                      N.O.-------N.C.-----TeSys P/N--------Pre-TeSys P/N
                                                      --1-----------0--------LADN10----------LA1DN10
                                                      --0-----------1--------LADN01----------LA1DN01

                                                      Side Mounting; maximum of 1 block on each side for D2 Series and Tesys Series 40 through 80 amp contactors. Tesys 9 through 32, 115, and 150 amps contactors will accept 1 block and is limited to left side only. (*) DC control devices will not accept side mount auxiliaries.
                                                      (*) DC control exceptions that will accept one left side mounted auxiliary: LC1D115 & LC1D150.

                                                      N.O.-------N.C.-----TeSys P/N--------Pre-TeSys P/N
                                                      --1-----------1--------LAD8N11----------LA8DN11
                                                      --2-----------0--------LAD8N20----------LA8DN20
                                                      --0-----------2--------LAD8N02----------N/A

                                                      Footnotes:
                                                      {1} EN50 012 Machine Tool Terminal Markings
                                                      {2} (2) NO Sealed Dust Tight Contacts
                                                      {3} Gold Flash Contacts
                                                      {4} (1) NO & (1) NC Standard and (1) NO & (1) NC Make Before Break
                                                      {5} (2) NO Dust Tight Contacts & (1) NO & (1) NC Standard Contacts
                                                      {6} (2) NO Dust Tight Contacts & (2) NO Standard Contacts

                                                      Is 240 volt replacement control coil available for LC1D11500?

                                                      Issue:
                                                      Identifying replacement coil part number

                                                      Product Line:
                                                      IEC contactors and starters

                                                      Environment:
                                                      Products sold and used in the United States

                                                      Cause:
                                                      Replacement control coil needed for older style Tesys Contactor

                                                      Resolution:
                                                      Yes, order LX1D8U5 for 50 hertz, LX1D8U6 for 60 hertz or LX1D8U7 for 50/60 hertz. Average coil consumption is 300 VA inrush 22 VA sealed for 50 hertz, 300 VA inrush 22 VA sealed for 60 hertz and 280 to 350 VA inrush 2 to 18 VA sealed for 50/60 hertz.


                                                      CTA-ID : 11321

                                                      What are the stand alone short circuit current ratings on the LC1D** contactors?

                                                      Issue:
                                                      Tesys D SCCR

                                                      Product Line:
                                                      Contactors and Overload Relays

                                                      Environment:
                                                      TeSys™ D Contactors and Overload Relays
                                                       
                                                      Resolution:
                                                      The contactors have a stand alone withstand rating that has been established by UL and is based on the maximum horsepower rating for a given device. However, only combination type starters are supplied with short circuit protective devices having a short circuit current rating.

                                                      They are as follows:
                                                      Horsepower SCCR (A)

                                                      0 thru 1 1,000
                                                      1 thru 50 5,000
                                                      51 thru 200 10,000
                                                      201 thru 400 18,000
                                                      401 thru 600 30,000
                                                      601 thru 900 42,000
                                                      901 thru 1600 85,000
                                                      1601+ 100,000

                                                      What is the power terminal lug data for the LC1D40, LC1D50, LC1D65, LP1D40, LP1D50, and LP1D65 contactor?

                                                      Issue:
                                                      Identifying power terminal lug data for the D2 style contactors

                                                      Product Line:
                                                      Tesys D line contactors

                                                      Environment:
                                                      Products sold and used in the United States

                                                      Cause:
                                                      Power terminal lug data required

                                                      Resolution:
                                                      For contactors with screw clamp terminals:
                                                      stranded cable w/o cable end : One #10-3 AWG or Two #10-4 AWG per terminal.
                                                      stranded cable w/cable end: One #10-4 AWG or Two #12-2 AWG per terminal.
                                                      solid cable: One #10-3 AWG or Two #10-6 AWG per terminal.

                                                      What is the part number for the red safety cover to go on the LC1D contactors?

                                                      The LC1D09-65 take the LAD9ET1S
                                                      The LC1D80-95 take the LAD9ET3S 
                                                      The LC1D115-150 take the LAD9ET4S

                                                      What is the part number for the replacement contactor for the LC1D1210N7?

                                                      The part number for the replacement contactor for the LC1D1210N7 is - LC1D12N7

                                                      For further information, visit the link below:-
                                                      https://www.schneider-electric.com.au/en/search/LC1D12N7
                                                      User-added image

                                                      What is the part number for a 3 pole 115amp contactor with 240VAC coil?

                                                      The part number for a 3 pole 115amp contactor with 240VAC coil is - LC1D1156U7

                                                      For further information , visit link below:-
                                                      https://www.schneider-electric.com.au/en/search/LC1D1156
                                                      User-added image

                                                      Do the Everlink reversing contactors come with electrical interlocking?

                                                      Issue:
                                                      Looking for electrical interlock kit for the LC1D65A Everlnk contactors

                                                      Product line:
                                                      Tesys D LC1D40A, LC1D50A, LC1D65A

                                                      Environment:
                                                      Everlink, all voltage codes

                                                      Cause:
                                                      Old D2 version offered an electrical interlock kit

                                                      Resolution:
                                                      The current Everlink version does not offer an electrical interlock kit.  The customer can wire electrical interlocking using the normally closed contacts provided on the contactor.

                                                      What is the coil consumption or burden for the Tesys LC*D** contactors?

                                                      * 1 or 2
                                                      ** 09 through 38

                                                      Issue:
                                                      Coil consumption or burden for the Tesys LC1D/2D contactors from 9A - 38A

                                                      Product Line: 
                                                      Contactors and Starters - IEC

                                                      Environment:
                                                      North American Products

                                                      Resolution:
                                                      All AC coils for the LC1D09 through LC1D38 3-pole contactors ( including ring tongue, quick connect and spring terminal versions ) have an inrush of 70 volt-amps for either 50 or 60 Hertz applications, and a sealed value of 7 volt-amps for 50Hertz applications or 7.5 volt-amps for 60 Hertz applications.

                                                      What is the part code for a 4P 2 N/O and 2 N/C 40Amp 240V ac coil contactor

                                                      Part code is LC1D258U7

                                                      Can the LE1D and LE2D enclosed Tesys D-Line contactors be obtained with DC control coils?

                                                      Issue:  
                                                      Tesys D enclosed starter with a DC control 

                                                      Product Line:
                                                       Enclosed Tesys D line starters

                                                      Environment:
                                                      North American Products
                                                       
                                                      Cause:
                                                      DC control circuit 
                                                       
                                                      Resolution:
                                                      Yes but limited to 24 VDC.

                                                      What is the part number for replacement contacts for the LC1D115 contactor??

                                                      The part number for replacement contacts for the LC1D115 contactor is - LA5D1158031
                                                      For further information on this part go to link below:-

                                                      https://www.schneider-electric.com.au/en/search/LA5D1158031

                                                      Does LC1D65AB7 3P (3 NO) TeSys Model D contactor have a normally opened and normally closed auxiliary contact?

                                                      What are the main DC power supply voltage and current ratings of LC1F115 & LC1F150 Contactors.

                                                      The LC1D115/150 was launched in 1996 in order to substitute the LC1F115/150 in the future, and offer better performances using an improved design.
                                                       
                                                      For this reason the characteristics of LC1F115 and LC1F150 were removed from most recent catalogues.
                                                       
                                                      Refer the attached data sheet for the specifications showing the DC characteristics and the details of the rated voltage & relevant current rating with the no. of poles in series.

                                                      Note: Use the attached sheet only for the LC1F115-150 contactor ratings as this is an old catalog sheet. For other rating contactors use the latest Technical Catalogue available on net (www.schneider-electric.com).

                                                      What is the overload for LC1D65AU7 Contactor, when rating is 20-25A ?

                                                      17-25 Amps = LRD325
                                                      23-32 Amps =LRD332

                                                      What is the replacement for LC1D115 with LX1D6G7 coil?

                                                      The replacement for LC1D115 with LX1D6G7 coil is LC1D1156F7

                                                      LC1D1156F7
                                                      TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 115 A - 110 V AC 50/60 Hz coil

                                                      For more information see:
                                                      https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=LC1D1156F7

                                                      What is the difference between the LC1D25E7 and LC1D258E7?

                                                      The LC1D25E7 is a 3 Poles 25 Amps (AC-3) Contactor

                                                      Where as

                                                      The LC1D258E7 is a 4 Pole (2NO + 2NC) 25 Amps (AC-3) Contactor

                                                      https://www.schneider-electric.com.au/en/search/LC1D25E7

                                                      Are the LC1D115 and LC1D150 contactors din rail mountable?

                                                      Issue: 
                                                      LC1D115 and D150 mounting

                                                      Product Line:
                                                       Tesys D contactors

                                                      Environment:
                                                      Products sold and used in the United States
                                                       
                                                      Cause:
                                                      Din rail mounting desired for large D line contactor
                                                       
                                                      Resolution:
                                                       
                                                      Yes, they use 2-35mm din rails


                                                       

                                                      What is the mechanical interlock for the LC1D115 contactor?

                                                      Issue:
                                                      Interlock needed for a pair of LC1D115 contactors

                                                      Product Line:
                                                      NEMA combination starters

                                                      Environment:
                                                      Products sold and used in the United States

                                                      Cause:
                                                      Application requires mechanical interlocking

                                                      Resolution:
                                                      LA9D11502. It includes the electrical interlocks.

                                                       

                                                      What is the part code for terminal shrouds to fit LC1D115 or LC1D150

                                                      The part code is LA9D115703 for 3 pole
                                                      The part code for 4 pole is LA9D115704

                                                      What is the part number for 60A contactor with 240V/415V coil?

                                                      What is the difference between a LC1D65A3U7 and LC1D65AU7?

                                                      The difference between the LC1D65A3U7 and the LC1D65AU7 is that the Control connections are spring terminals for the LC1D65A3U7 and screw clamp terminals for the LC1D65AU7
                                                      see data sheets for comparrisons...
                                                      https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=lc1d65a3u7

                                                      https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=lc1d65au7
                                                      User-added image.................User-added image

                                                      What is the reference for the separate mounting kit for LRD4369 overload relay

                                                      The LRD43xx type of thermal overload relays are directly mounted to the contactors LC1D115 & LC1D150 only. There is no separate mounting kit for the LRD43xx.

                                                      If a separate mounting is required for the contactors LC1D115 or LC1D150 type, then LRD336xx shall be selected as these range of overload relays have indepentdent mounting and have similar setting range and are of Class 10A.

                                                      What does the (3) designate in the part number LC1D123G7?

                                                      For spring termination versions, add (3) to the catalog number prior to adding the voltage code. (ex. LC1D12G7 becomes a LC1D123G7 or LC1D40AG7 becomes LC1D40A3G7). This applies only for the LC1D09 - LC1D65A contactors. Note: For the LC1D40A to D65A, the spring terminals are only on the control terminations and not on power terminations.



                                                      CTA-ID : 2053127

                                                      What is the Tesys D-Line maximum frequency for Power Poles?

                                                      Issue:
                                                      Checking on the maximum Hz voltage that can be applied to the Tesys D-line contactors.

                                                      Product Line:
                                                      Tesys D Contactors

                                                      Environment:
                                                      IEC Contactors and Starters

                                                      Cause:
                                                      Product Characteristics

                                                      Resolution:
                                                      These units have been tested for frequencies 25Hz to 400hz within the operational current of the device .  No testing has been done beyond this frequency.

                                                      Does the 150A IEC contactor LC1D150BD with a 24 volt DC coil have a coil suppressor built in?

                                                      Issue: 
                                                      Does the LC1D150 with a DC coil include suppression? 

                                                      Product Line:
                                                       Tesys D line contactors and accessories

                                                      Environment:
                                                      Products sold and used in the United States
                                                       
                                                      Cause:
                                                       Identifying components and accessories
                                                       
                                                      Resolution:
                                                       
                                                      Yes. Suppression is built into the 150A DC contactor coil.
                                                       

                                                      Which rectifier is required for the LX9F*917 48V coil?

                                                      Issue:
                                                      Which rectifier is required for the LX9F*917 48V coil?

                                                      Product Line:
                                                      TeSys F-Line Contactors

                                                      Environment:
                                                      All Product Lines

                                                      Cause:
                                                      Can not find it in the Digest

                                                      Resolution:
                                                      For the LX9FJ917, LX9FK917, and LX9FL917 48V coils, use rectifier part number: DR5TF4V
                                                      Show More