TeSys D Contactor, 3P(3 NO), AC-3, <= 440V, 115A, 48VDC, Standard Coil

TeSys D Contactor, 3P(3 NO), AC-3, <= 440V, 115A, 48VDC, Standard Coil

TeSys D Contactor, 3P(3 NO), AC-3, <= 440V, 115A, 48VDC, Standard Coil

Item Number: LC1D1156ED

Retail
$3,423.82
RRP (Inc. GST)

Product Dimensions

Width icon

Width120 mm

Height icon

Height158 mm

Depth icon

Depth136 mm

See full specifications

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

TeSys D

Range

TeSys

Product or component type

contactor

Sustainable offer status

Green Premium product

Warranty

18 months

Physical

[Ue] rated operational voltage

  • power circuit: <= 1000 V AC 25...400 Hz
  • power circuit: <= 300 V DC
    • [Ie] rated operational current

    • 200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
    • 115 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
      • Electrical durability

      • 0.8 Mcycles 200 A AC-1 at Ue <= 440 V
      • 0.95 Mcycles 115 A AC-3 at Ue <= 440 V
        • Mounting support

        • plate
        • rail
          • Standards

          • CSA C22.2 No 14
          • EN 60947-4-1
          • EN 60947-5-1
          • IEC 60947-4-1
          • IEC 60947-5-1
          • UL 508
            • Product certifications

            • CSA
            • UL
            • RINA
            • CCC
            • BV
            • LROS (Lloyds register of shipping)
            • DNV
            • GOST
            • GL
              • Connections - terminals

              • control circuit: lugs-ring terminals (external diameter: 8 mm)
              • power circuit: lugs-ring terminals (external diameter: 25 mm)
              • power circuit: bars 1 cable(s) - busbar cross section: 5 x 25 mm
                • Mechanical durability

                  8 Mcycles

                  Insulation resistance

                  > 10 MOhm for signalling circuit

                  IP degree of protection

                  IP20 front face conforming to IEC 60529

                  Ambient air temperature for storage

                  -60-80 °C

                  Height

                  158 mm

                  Width

                  120 mm

                  Depth

                  136 mm

                  Net weight

                  2.5 kg

                  EU RoHS Directive

                  Compliant

                  Mercury free

                  Yes

                  RoHS exemption information

                  Yes

                  China RoHS Regulation

                  Product out of China RoHS scope. Substance declaration for your information

                  Environmental Disclosure

                  ENVPEP060301EN

                  Circularity Profile

                  ENVEOLI100405EN

                  California proposition 65

                  WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.gov

                  Others

                  Product name

                  TeSys D

                  Device short name

                  LC1D

                  Contactor application

                • motor control
                • resistive load
                  • Utilisation category

                  • AC-1
                  • AC-4
                  • AC-3
                    • Poles description

                      3P

                      Pole contact composition

                      3 NO

                      Motor power kW

                    • 30 kW at 220...230 V AC 50/60 Hz (AC-3)
                    • 55 kW at 380...400 V AC 50/60 Hz (AC-3)
                    • 59 kW at 415...440 V AC 50/60 Hz (AC-3)
                    • 75 kW at 500 V AC 50/60 Hz (AC-3)
                    • 80 kW at 660...690 V AC 50/60 Hz (AC-3)
                    • 65 kW at 1000 V AC 50/60 Hz (AC-3)
                    • 18.5 kW at 400 V AC 50/60 Hz (AC-4)
                      • Motor power hp

                      • 30 hp at 200/208 V AC 50/60 Hz for 3 phases motors
                      • 40 hp at 230/240 V AC 50/60 Hz for 3 phases motors
                      • 75 hp at 460/480 V AC 50/60 Hz for 3 phases motors
                      • 100 hp at 575/600 V AC 50/60 Hz for 3 phases motors
                        • Control circuit type

                          DC standard

                          [Uc] control circuit voltage

                          48 V DC

                          Auxiliary contact composition

                          1 NO + 1 NC

                          [Uimp] rated impulse withstand voltage

                          8 kV conforming to IEC 60947

                          Overvoltage category

                          III

                          [Ith] conventional free air thermal current

                          200 A (at 60 °C) for power circuit

                          Irms rated making capacity

                        • 1260 A at 440 V for power circuit conforming to IEC 60947
                        • 140 A AC for signalling circuit conforming to IEC 60947-5-1
                        • 250 A DC for signalling circuit conforming to IEC 60947-5-1
                          • Rated breaking capacity

                            1100 A at 440 V for power circuit conforming to IEC 60947

                            [Icw] rated short-time withstand current

                          • 250 A 40 °C - 10 min for power circuit
                          • 550 A 40 °C - 1 min for power circuit
                          • 950 A 40 °C - 10 s for power circuit
                          • 1100 A 40 °C - 1 s for power circuit
                          • 100 A - 1 s for signalling circuit
                          • 120 A - 500 ms for signalling circuit
                          • 140 A - 100 ms for signalling circuit
                            • Associated fuse rating

                            • 250 A gG at <= 690 V coordination type 1 for power circuit
                            • 200 A gG at <= 690 V coordination type 2 for power circuit
                            • 10 A gG for signalling circuit
                              • Average impedance

                                0.6 mOhm - Ith 200 A 50 Hz for power circuit

                                [Ui] rated insulation voltage

                              • power circuit: 600 V CSA certified
                              • power circuit: 600 V UL certified
                              • power circuit: 1000 V conforming to IEC 60947-4-1
                              • signalling circuit: 690 V conforming to IEC 60947-1
                              • signalling circuit: 600 V CSA certified
                              • signalling circuit: 600 V UL certified
                                • Power dissipation per pole

                                • 24 W AC-1
                                • 7.9 W AC-3
                                  • Protective cover

                                    with

                                    Tightening torque

                                  • control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver flat Ø 6 mm M3.5
                                  • control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver Philips No 2 M3.5
                                  • power circuit: 12 N.m - on lugs-ring terminals hexagonal screw head 13 mm M8
                                  • power circuit: 12 N.m - on bars hexagonal screw head 13 mm M8
                                    • Operating time

                                    • 20...35 ms closing
                                    • 40...75 ms opening
                                      • Safety reliability level

                                      • B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
                                      • B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
                                        • Maximum operating rate

                                          1200 cyc/h 60 °C

                                          Coil technology

                                          with integral suppression device

                                          Time constant

                                          25 ms

                                          Inrush power in W

                                          270-365 W (at 20 °C)

                                          Hold-in power consumption in W

                                          2.4-5.1 W at 20 °C

                                          Auxiliary contacts type

                                        • type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
                                        • type mirror contact 1 NC conforming to IEC 60947-4-1
                                          • Signalling circuit frequency

                                            25...400 Hz

                                            Minimum switching current

                                            5 mA for signalling circuit

                                            Minimum switching voltage

                                            17 V for signalling circuit

                                            Non-overlap time

                                          • 1.5 ms on de-energisation between NC and NO contact
                                          • 1.5 ms on energisation between NC and NO contact
                                            • Contact compatibility

                                              M10

                                              Compatibility code

                                              LC1D

                                              Protective treatment

                                              TH conforming to IEC 60068-2-30

                                              Pollution degree

                                              3

                                              Operating altitude

                                              3000 m without derating

                                              Fire resistance

                                              850 °C conforming to IEC 60695-2-1

                                              Flame retardance

                                              V1 conforming to UL 94

                                              Mechanical robustness

                                            • vibrations contactor open: 2 Gn, 5...300 Hz
                                            • vibrations contactor closed: 4 Gn, 5...300 Hz
                                            • shocks contactor closed: 15 Gn for 11 ms
                                            • shocks contactor open: 6 Gn for 11 ms
                                              • Unit Type of Package 1

                                                PCE

                                                Number of Units in Package 1

                                                1

                                                Package 1 Weight

                                                2.11 kg

                                                Package 1 Height

                                                16.8 cm

                                                Package 1 width

                                                20.8 cm

                                                Package 1 Length

                                                18.5 cm

                                                WEEE

                                                The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

                                                PVC free

                                                Yes
                                                Show all specifications

                                                Documents & downloads

                                                hide show
                                                Filter items
                                                • All

                                                • CAD Files and Packs

                                                • Product Brochures

                                                • Technical Data Catalogues

                                                • End of Life Manual

                                                • Installation Instruction

                                                • Product Environmental

                                                • Data Bulletin

                                                • Declaration of Conformity

                                                • Certificates (MSDS)

                                                Frequently Asked Questions

                                                hide show

                                                What is the maximum UL/CSA AC voltage rating of the LC1D power contacts ?

                                                Issue:
                                                Identifying maximum voltage of an LC1D contactor

                                                Product Line:
                                                TeSys D Contactors

                                                Environment:
                                                IEC contactors and starters used in North America

                                                Cause:
                                                n/a

                                                Resolution:
                                                IThe maximum voltage per UL and CSA is 600VAC. 
                                                 

                                                What is the difference between LC1D115 and LC1D1156?

                                                The 6 in LC1D1156.. is that the 6 denotes lug bar terminals. Use LC1D115.. for cable connections.


                                                 

                                                What is the terminal shroud part number for a LC1D1156**

                                                The part code is LA9D115703

                                                Does the LC1D1156U7 come with 1NO & 1NC Aux contact

                                                Yes - all the D range contactors have one of each aux contact

                                                Where are the control coil terminals for TeSys LC1D09 to LC1D38 contactor?

                                                Issue:
                                                Determine the control coil terminal marking and location on LC1D09 to LC1D38 contactor

                                                Product Line: 
                                                Tesys D Contactors

                                                Environment:
                                                IEC contactors

                                                Resolution:
                                                The coil terminals are marked A1 and A2, you can see them on the front of the contactor on the white part (control section).  They are next to the auxiliary contact (13/14, 21/22) terminals.
                                                 

                                                What is the part number for the 415V AC Coil for the LC1D1156 Contactor?

                                                The part number for the 415V AC Coil for the LC1D1156 Contactor is "LX1D8N7"

                                                https://www.schneider-electric.com.au/en/search/lx1d8n7


                                                 

                                                What is the interlock to use with the lcd1156**

                                                 The interlock is LA9D11502

                                                Are the D-Line contactors rated to break DC voltages?

                                                Issue: 
                                                Can the TeSys D line be used to control DC loads? 

                                                Product Line:
                                                Tesys D contactors

                                                Environment:
                                                Products sold and used in the United States
                                                 
                                                Cause:
                                                 DC power circuit
                                                 
                                                Resolution:
                                                 
                                                Yes, 75 VDC (125 VDC for D115 & D150) per pole which means that through a four pole device breaking 300 VDC is possible by wiring all four power poles in series. However, be aware that the device current ratings will differ according to the number of poles in series and the type of application.

                                                Devices are suitable but not UL Listed for DC applications.

                                                More information on their DC ratings can be found in the current TeSys Motor Control and Protection Compentns catalog: https://www.schneider-electric.us/en/download/document/MKTED210011EN/


                                                 

                                                What are the coil voltage codes for the LC1D115 / LC2D115 and LC1D150 / LC2D150 TeSys contactor?

                                                Issue:
                                                LC1D115 / LC2D115 and LC1D150 / LC2D150

                                                Product Line:
                                                Tesys D line Contactors

                                                Environment:
                                                North America

                                                Resolution:
                                                The following list the more common voltage suffix codes for these product lines.  For a more comprehensive list and to determine compatibility with a given product, refer to the catalog below.

                                                Note 1: LC1D150 contactors are only available with *7 coil codes.
                                                Note 2: Coil Code ending number represents frequency rating as follows:
                                                5 = 50 Hertz
                                                6 = 60 Hertz
                                                7 = 50/60 Hertz

                                                AC Volts ___Code                DC Volts ___Code
                                                24 ___ B5 or B6 or B7          12 ___ Not Avail.        
                                                42 ___ D5 or D7                   24 ___ BD
                                                48 ___ E5 or E6 or E7          36 ___ CD
                                                110 ___ F5 or F6 or F7         48 ___ ED
                                                115 ___ FE5 or FE7             60 ___ ND
                                                120 ___ G6 or G7                72 ___ SD
                                                127 ___ FC5 or FC7            110 ___ FD
                                                208 ___ L6 or LE7               125 ___ GD
                                                220 ___ M5 or M6 or M7       220 ___ MD
                                                230 ___ P5 or P7                 250 ___ UD
                                                240 ___ U5 or U6 or U7        440 ___ RD
                                                277 ___ W6 or UE7                
                                                380 ___ Q5 or Q6 or Q7                
                                                400 ___ V5 or V7                
                                                415 ___ N5 or N7                
                                                440 ___ R5 or R6 or R7                
                                                480 ___ T6 or T7                
                                                500 ___ S5 or S7                


                                                 

                                                What is the code for a contactor rated at 100A AC3 with a 240V AC coil ?

                                                Code = LC1D1156U7 ( 3 Pole Contactor comes with 1 N/C + 1 N/O Auxilliary as a standard ) 

                                                What is the difference between LA9D11569 and LA9D115691?

                                                Issue:
                                                Identifying differences between two part numbers

                                                Product Line:
                                                IEC contactors and starters

                                                Environment:
                                                Products sold and used in the United States

                                                Cause:
                                                Selecting between two similar part numbers

                                                Resolution:
                                                LA9D11569 is a set of power connections. LA9D115691 is the bottom connector only as shown on page 16-9 of Digest 173 for the LC1D115 and LC1D150 contactor.


                                                 

                                                What is the altitude derating for a TeSys D-Line contactor?

                                                Issue:​
                                                What is the altitude derating for a TeSys D-Line contactor?

                                                Product Line:
                                                Digest 177 Section 18 : Contactors and Starters, IEC

                                                Environment:
                                                North American Products

                                                Resolution:
                                                The contactors are fully rated up to 3000 meters. Following are derating multipliers for altitudes above 3000 meters for both voltage and current:

                                                Voltage
                                                3500m x 0.90
                                                4000m x 0.80
                                                4500m x 0.70
                                                5000m x 0.60

                                                Current
                                                3500m x 0.92
                                                4000m x 0.90
                                                4500m x 0.88
                                                5000m x 0.86

                                                For example, an LC1D80 at 5000 meters:
                                                - The maximum rated operational voltage is 1,000V (IEC947-4) and 690V (UL/CSA). At 5000 meters it becomes 1000V x 0.6 = 600V (IEC947-4) and 690V x 0.6 = 414V (UL/CSA).
                                                - The maximum rated operational AC3 current is 80A. At 5000 meters it becomes 80A x 0.86 = 68A.



                                                 
                                                Show More