Key Features & Specifications

hide show
Range of product
TeSys D
Range
TeSys
Product name
TeSys D
Product or component type
contactor
Device short name
LC1D
Contactor application
resistive load
Utilisation category
AC-1
Poles description
4P
Pole contact composition
4 NO
[Ue] rated operational voltage
  • power circuit: <= 1000 V AC 25...400 Hz
  • power circuit: <= 460 V DC
    • [Ie] rated operational current
      200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
      Control circuit type
      AC at 50/60 Hz
      [Uc] control circuit voltage
      48 V AC 50/60 Hz
      [Uimp] rated impulse withstand voltage
      8 kV conforming to IEC 60947
      Overvoltage category
      III
      [Ith] conventional free air thermal current
      200 A (at 60 °C) for power circuit
      Irms rated making capacity
      1260 A at 440 V for power circuit conforming to IEC 60947
      Rated breaking capacity
      1100 A at 440 V for power circuit conforming to IEC 60947
      [Icw] rated short-time withstand current
    • 250 A 40 °C - 10 min for power circuit
    • 550 A 40 °C - 1 min for power circuit
    • 950 A 40 °C - 10 s for power circuit
    • 1100 A 40 °C - 1 s for power circuit
      • Associated fuse rating
      • 250 A gG at <= 690 V coordination type 1 for power circuit
      • 200 A gG at <= 690 V coordination type 2 for power circuit
        • Average impedance
          0.6 mOhm - Ith 200 A 50 Hz for power circuit
          [Ui] rated insulation voltage
        • power circuit: 600 V CSA certified
        • power circuit: 600 V UL certified
        • power circuit: 1000 V conforming to IEC 60947-4-1
          • Electrical durability
            0.8 Mcycles 200 A AC-1 at Ue <= 440 V
            Power dissipation per pole
            24 W AC-1
            Protective cover
            with
            Mounting support
          • rail
          • plate
            • Standards
            • CSA C22.2 No 14
            • EN 60947-4-1
            • EN 60947-5-1
            • IEC 60947-4-1
            • IEC 60947-5-1
            • UL 508
              • Product certifications
              • BV
              • LROS (Lloyds register of shipping)
              • CCC
              • GL
              • DNV
              • RINA
              • GOST
              • UL
              • CSA
                • Connections - terminals
                • control circuit: lugs-ring terminals (external diameter: 8 mm)
                • power circuit: lugs-ring terminals (external diameter: 25 mm)
                • power circuit: bars 1 cable(s) - busbar cross section: 5 x 25 mm
                  • Tightening torque
                  • control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver flat Ø 6 mm M3.5
                  • control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver Philips No 2 M3.5
                  • power circuit: 12 N.m - on lugs-ring terminals hexagonal screw head 13 mm M8
                  • power circuit: 12 N.m - on bars hexagonal screw head 13 mm M8
                    • Operating time
                    • 6...20 ms opening
                    • 20...50 ms closing
                      • Safety reliability level
                      • B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
                      • B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
                        • Mechanical durability
                          8 Mcycles
                          Maximum operating rate
                          2400 cyc/h 60 °C
                          Coil technology
                          built-in bidirectional peak limiting diode suppressor
                          Control circuit voltage limits
                        • drop-out: 0.3...0.5 Uc AC 50/60 Hz (at 55 °C)
                        • operational: 0.8...1.15 Uc AC 50/60 Hz (at 55 °C)
                          • Inrush power in VA
                          • 280-350 VA 60 Hz cos phi 0.8 (at 20 °C)
                          • 280-350 VA 50 Hz cos phi 0.8 (at 20 °C)
                            • Hold-in power consumption in VA
                            • 2-18 VA 60 Hz cos phi 0.3 (at 20 °C)
                            • 2-18 VA 50 Hz cos phi 0.3 (at 20 °C)
                              • Heat dissipation
                                3-8 W at 50/60 Hz
                                Contact compatibility
                                M14
                                Compatibility code
                                LC1D
                                IP degree of protection
                                IP20 front face conforming to IEC 60529
                                Protective treatment
                                TH conforming to IEC 60068-2-30
                                Pollution degree
                                3
                                Ambient air temperature for operation
                                -5-60 °C
                                Ambient air temperature for storage
                                -60-80 °C
                                Permissible ambient air temperature around the device
                                -40-70 °C at Uc
                                Operating altitude
                                3000 m without
                                Fire resistance
                                850 °C conforming to IEC 60695-2-1
                                Flame retardance
                                V1 conforming to UL 94
                                Mechanical robustness
                              • vibrations contactor open: 2 Gn, 5...300 Hz
                              • vibrations contactor closed: 4 Gn, 5...300 Hz
                              • shocks contactor closed: 15 Gn for 11 ms
                              • shocks contactor open: 6 Gn for 11 ms
                                • Height
                                  158 mm
                                  Width
                                  155 mm
                                  Depth
                                  115 mm
                                  Net weight
                                  2.86 kg
                                  Sustainable offer status
                                  Green Premium product
                                  REACh Regulation
                                  Free of Substances of Very High Concern above the threshold
                                  EU RoHS Directive
                                  Compliant
                                  Mercury free
                                  Yes
                                  RoHS exemption information
                                  Yes
                                  China RoHS Regulation
                                  Product out of China RoHS scope. Substance declaration for your information
                                  Environmental Disclosure
                                  ENVPEP060301EN
                                  Circularity Profile
                                  ENVEOLI100405
                                  WEEE
                                  The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                                  Warranty
                                  18 months

                                  Documents & downloads

                                  hide show
                                  Filter items
                                  • All

                                  • CAD Files and Packs

                                  • Product Brochures

                                  • Movies

                                  • Catalog Page

                                  • Technical Data Catalogues

                                  • Technical Leaflet

                                  • Product Environmental

                                  • End of Life Manual

                                  • Installation Instruction

                                  • Handout

                                  • Data Bulletin

                                  • Operating Manuals

                                  • Application Solutions

                                  • Declaration of Conformity

                                  • Certificates (MSDS)

                                  • White Paper

                                  • eTechPub

                                  • Marine Certificate

                                  • Software - Released