CONTACTOR
TeSys LC1D115004 reversing contactor, 4 poles, with screw clamp terminals or lugs, with cover, 115A
CONTACTOR
TeSys LC1D115004 reversing contactor, 4 poles, with screw clamp terminals or lugs, with cover, 115A

TeSys D Contactor, 4P(4 NO), AC-1, <= 440V, 200A, 24 VAC 50/60 Hz Coil

Catalogue Number: LC1D1150046B7
CONTACTOR
TeSys LC1D115004 reversing contactor, 4 poles, with screw clamp terminals or lugs, with cover, 115A
CONTACTOR
TeSys LC1D115004 reversing contactor, 4 poles, with screw clamp terminals or lugs, with cover, 115A
Retail
$3,404.69
RRP (Inc. GST)

Specifications

hide show
Range of product
TeSys D
Range
TeSys
Product name
TeSys D
Product or component type
contactor
Device short name
LC1D
Contactor application
resistive load
Utilisation category
AC-1
Poles description
4P
Pole contact composition
4 NO
[Ue] rated operational voltage
  • power circuit: <= 1000 V AC 25...400 Hz
  • power circuit: <= 460 V DC
    • [Ie] rated operational current
      200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
      Control circuit type
      AC at 50/60 Hz
      [Uc] control circuit voltage
      24 V AC 50/60 Hz
      [Uimp] rated impulse withstand voltage
      8 kV conforming to IEC 60947
      Overvoltage category
      III
      [Ith] conventional free air thermal current
      200 A (at 60 °C) for power circuit
      Irms rated making capacity
      1260 A at 440 V for power circuit conforming to IEC 60947
      Rated breaking capacity
      1100 A at 440 V for power circuit conforming to IEC 60947
      [Icw] rated short-time withstand current
    • 250 A 40 °C - 10 min for power circuit
    • 550 A 40 °C - 1 min for power circuit
    • 950 A 40 °C - 10 s for power circuit
    • 1100 A 40 °C - 1 s for power circuit
      • Associated fuse rating
      • 250 A gG at <= 690 V coordination type 1 for power circuit
      • 200 A gG at <= 690 V coordination type 2 for power circuit
        • Average impedance
          0.6 mOhm - Ith 200 A 50 Hz for power circuit
          [Ui] rated insulation voltage
        • power circuit: 600 V CSA certified
        • power circuit: 600 V UL certified
        • power circuit: 1000 V conforming to IEC 60947-4-1
          • Electrical durability
            0.8 Mcycles 200 A AC-1 at Ue <= 440 V
            Power dissipation per pole
            24 W AC-1
            Protective cover
            with
            Mounting support
          • rail
          • plate
            • Standards
            • CSA C22.2 No 14
            • EN 60947-4-1
            • EN 60947-5-1
            • IEC 60947-4-1
            • IEC 60947-5-1
            • UL 508
              • Product certifications
              • GL
              • GOST
              • CSA
              • CCC
              • UL
              • DNV
              • LROS (Lloyds register of shipping)
              • RINA
              • BV
                • Connections - terminals
                • control circuit: lugs-ring terminals (external diameter: 8 mm)
                • power circuit: lugs-ring terminals (external diameter: 25 mm)
                • power circuit: bars 1 cable(s) - busbar cross section: 5 x 25 mm
                  • Tightening torque
                  • control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver flat Ø 6 mm M3.5
                  • control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver Philips No 2 M3.5
                  • power circuit: 12 N.m - on lugs-ring terminals hexagonal screw head 13 mm M8
                  • power circuit: 12 N.m - on bars hexagonal screw head 13 mm M8
                    • Operating time
                    • 6...20 ms opening
                    • 20...50 ms closing
                      • Safety reliability level
                      • B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
                      • B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
                        • Mechanical durability
                          8 Mcycles
                          Maximum operating rate
                          2400 cyc/h 60 °C
                          Coil technology
                          built-in bidirectional peak limiting diode suppressor
                          Inrush power in VA
                        • 280-350 VA 60 Hz cos phi 0.8 (at 20 °C)
                        • 280-350 VA 50 Hz cos phi 0.8 (at 20 °C)
                          • Hold-in power consumption in VA
                          • 2-18 VA 60 Hz cos phi 0.3 (at 20 °C)
                          • 2-18 VA 50 Hz cos phi 0.3 (at 20 °C)
                            • Heat dissipation
                              3-8 W at 50/60 Hz
                              Contact compatibility
                              M14
                              Compatibility code
                              LC1D
                              IP degree of protection
                              IP20 front face conforming to IEC 60529
                              Protective treatment
                              TH conforming to IEC 60068-2-30
                              Pollution degree
                              3
                              Ambient air temperature for storage
                              -60-80 °C
                              Operating altitude
                              3000 m without derating
                              Fire resistance
                              850 °C conforming to IEC 60695-2-1
                              Flame retardance
                              V1 conforming to UL 94
                              Mechanical robustness
                            • vibrations contactor open: 2 Gn, 5...300 Hz
                            • vibrations contactor closed: 4 Gn, 5...300 Hz
                            • shocks contactor closed: 15 Gn for 11 ms
                            • shocks contactor open: 6 Gn for 11 ms
                              • Height
                                158 mm
                                Width
                                155 mm
                                Depth
                                115 mm
                                Net weight
                                2.86 kg
                                Unit Type of Package 1
                                PCE
                                Number of Units in Package 1
                                1
                                Package 1 Weight
                                2.37 kg
                                Package 1 Height
                                16.8 cm
                                Package 1 width
                                21.2 cm
                                Package 1 Length
                                18.5 cm
                                Sustainable offer status
                                Green Premium product
                                EU RoHS Directive
                                Compliant
                                Mercury free
                                Yes
                                RoHS exemption information
                                Yes
                                China RoHS Regulation
                                Product out of China RoHS scope. Substance declaration for your information
                                Environmental Disclosure
                                ENVPEP060301EN
                                Circularity Profile
                                ENVEOLI100405EN
                                WEEE
                                The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                                PVC free
                                Yes
                                Warranty
                                18 months

                                Documents & downloads

                                hide show
                                Filter items
                                • All

                                • CAD Files and Packs

                                • Product Brochures

                                • End of Life Manual

                                • Installation Instruction

                                • Product Environmental

                                • Certificates (MSDS)

                                • Declaration of Conformity

                                Frequently Asked Questions

                                hide show

                                Video: What auxiliary contact modules are available for the LC1D and LC2D contactors?

                                Issue:
                                Auxiliary contact modules for the LC1D and LC2D contactors

                                Product Line: 
                                Contactor and Starters - IEC

                                Environment:
                                North American Products

                                Resolution:
                                Select based on application requirements. Please note that the TeSys and Pre-TeSys auxiliary blocks are backward/forward compatible.
                                Front Mounting; maximum of 1 block per contactor:

                                N.O.-------N.C.-----TeSys P/N--------Pre-TeSys P/N
                                --1-----------1---------LADN11-----------LA1DN11
                                --1-----------1---------LADN11G---------LA1DN11G (See Footnote 1)
                                --1-----------1---------LADN11P---------LA1DN11P (See Footnote 1)
                                --2-----------0---------LADN20-----------LA1DN20
                                --2-----------0---------LA1DX20---------LA1DX20 (See Footnote 2)
                                --2-----------0---------LA1DY20---------LA1DY20 (See Footnote 3)
                                --0-----------2---------LADN02-----------LA1DN02
                                --2-----------2---------LADN22-----------LA1DN22
                                --2-----------2---------LADN22G---------LA1DN22G (See Footnote 1)
                                --2-----------2---------LADN22P---------LA1DN22P (See Footnote 1)
                                --2-----------2---------LADC22------------LA1DC22 (See Footnote 4)
                                --3-----------1---------LADN31------------LA1DN31
                                --3-----------1---------LA1DZ31----------LA1DZ31 (See Footnote 5)
                                --1-----------3---------LADN13------------LA1DN13
                                --4-----------0---------LADN40------------LA1DN40
                                --4-----------0---------LA1DZ40-----------LA1DZ40 (See Footnote 6)
                                --0-----------4---------LADN04------------LA1DN04




                                Front Mounting; maximum of 1 block per contactor: For use with D2 Series 25 amp through 80 amp contactors and TeSys Series 40 amp through 80 amp only.

                                N.O.-------N.C.-----TeSys P/N--------Pre-TeSys P/N
                                --1-----------0--------LADN10----------LA1DN10
                                --0-----------1--------LADN01----------LA1DN01

                                Side Mounting; maximum of 1 block on each side for D2 Series and Tesys Series 40 through 80 amp contactors. Tesys 9 through 32, 115, and 150 amps contactors will accept 1 block and is limited to left side only. (*) DC control devices will not accept side mount auxiliaries.
                                (*) DC control exceptions that will accept one left side mounted auxiliary: LC1D115 & LC1D150.

                                N.O.-------N.C.-----TeSys P/N--------Pre-TeSys P/N
                                --1-----------1--------LAD8N11----------LA8DN11
                                --2-----------0--------LAD8N20----------LA8DN20
                                --0-----------2--------LAD8N02----------N/A

                                Footnotes:
                                {1} EN50 012 Machine Tool Terminal Markings
                                {2} (2) NO Sealed Dust Tight Contacts
                                {3} Gold Flash Contacts
                                {4} (1) NO & (1) NC Standard and (1) NO & (1) NC Make Before Break
                                {5} (2) NO Dust Tight Contacts & (1) NO & (1) NC Standard Contacts
                                {6} (2) NO Dust Tight Contacts & (2) NO Standard Contacts

                                What is the color scheme of the Tesys D-Line contactors?

                                Issue:
                                Looking for different color scheme of the Tesys D-Line contactors.

                                Product Line:
                                Tesys D Contactors

                                Environment:
                                LC1D contactors

                                Resolution:
                                Beige and dark gray.
                                 

                                What is the part number for a replacement 4 pole 25amp contactor for the LC1D12004B7?

                                The part number for a replacement 4 pole 25amp contactor for the LC1D12004B7 is - LC1DT25B7

                                For further information, visit the link below:-
                                https://www.schneider-electric.com.au/en/search/LC1DT25B7
                                User-added image

                                 

                                What code is a mechanical interlock for the 4pole LC1D1150046 contactor?

                                LA9D11502 will fit the 4p LC1D115 and LC1D150 contactors

                                What are the stand alone short circuit current ratings on the LC1D** contactors?

                                Issue:
                                Tesys D SCCR

                                Product Line:
                                Contactors and Overload Relays

                                Environment:
                                TeSys™ D Contactors and Overload Relays
                                 
                                Resolution:
                                The contactors have a stand alone withstand rating that has been established by UL and is based on the maximum horsepower rating for a given device. However, only combination type starters are supplied with short circuit protective devices having a short circuit current rating.

                                They are as follows:
                                Horsepower SCCR (A)

                                0 thru 1 1,000
                                1 thru 50 5,000
                                51 thru 200 10,000
                                201 thru 400 18,000
                                401 thru 600 30,000
                                601 thru 900 42,000
                                901 thru 1600 85,000
                                1601+ 100,000

                                Are the D-Line contactors rated to break DC voltages?

                                Issue: 
                                Can the TeSys D line be used to control DC loads? 

                                Product Line:
                                Tesys D contactors

                                Environment:
                                Products sold and used in the United States
                                 
                                Cause:
                                 DC power circuit
                                 
                                Resolution:
                                 
                                Yes, 75 VDC (125 VDC for D115 & D150) per pole which means that through a four pole device breaking 300 VDC is possible by wiring all four power poles in series. However, be aware that the device current ratings will differ according to the number of poles in series and the type of application.

                                Devices are suitable but not UL Listed for DC applications.

                                More information on their DC ratings can be found in the current TeSys Motor Control and Protection Compentns catalog: https://www.schneider-electric.us/en/download/document/MKTED210011EN/


                                 

                                What are the coil voltage codes for the LC1D115 / LC2D115 and LC1D150 / LC2D150 TeSys contactor?

                                Issue:
                                LC1D115 / LC2D115 and LC1D150 / LC2D150

                                Product Line:
                                Tesys D line Contactors

                                Environment:
                                North America

                                Resolution:
                                The following list the more common voltage suffix codes for these product lines.  For a more comprehensive list and to determine compatibility with a given product, refer to the catalog below.

                                Note 1: LC1D150 contactors are only available with *7 coil codes.
                                Note 2: Coil Code ending number represents frequency rating as follows:
                                5 = 50 Hertz
                                6 = 60 Hertz
                                7 = 50/60 Hertz

                                AC Volts ___Code                DC Volts ___Code
                                24 ___ B5 or B6 or B7          12 ___ Not Avail.        
                                42 ___ D5 or D7                   24 ___ BD
                                48 ___ E5 or E6 or E7          36 ___ CD
                                110 ___ F5 or F6 or F7         48 ___ ED
                                115 ___ FE5 or FE7             60 ___ ND
                                120 ___ G6 or G7                72 ___ SD
                                127 ___ FC5 or FC7            110 ___ FD
                                208 ___ L6 or LE7               125 ___ GD
                                220 ___ M5 or M6 or M7       220 ___ MD
                                230 ___ P5 or P7                 250 ___ UD
                                240 ___ U5 or U6 or U7        440 ___ RD
                                277 ___ W6 or UE7                
                                380 ___ Q5 or Q6 or Q7                
                                400 ___ V5 or V7                
                                415 ___ N5 or N7                
                                440 ___ R5 or R6 or R7                
                                480 ___ T6 or T7                
                                500 ___ S5 or S7                


                                 

                                What replaces the LC1D12004M7 contactor?

                                Will the LAD** time delay auxiliary contact module fit the D2 series pre-Tesys contactors?

                                Issue:
                                Can new accessories be used on older style contactors

                                Product Line:
                                IEC contactors and starters

                                Environment:
                                Products sold and used in the United States

                                Cause:
                                Identifying product compatibility

                                Resolution:
                                Yes, all front mount D2 and Tesys series auxiliary modules are backward forward compatible.


                                 

                                What is the difference between the LC1D1506N7 and the LC1D150N7?

                                The LC1D1506N7 can accept 5X25mm Bars aswell as Lugs or ring terminals. The LC1D150N7 only accepts cable lugs upto 120mm2.

                                Does the LC1D1156U7 come with 1NO & 1NC Aux contact

                                Yes - all the D range contactors have one of each aux contact

                                What is the replacement contactor for the LC1D65004F5?

                                The new code is LC1DT80AF7 which is made to order.
                                Show More