Quantcast

TeSys D Contactor, 3P(3 NO), AC-3, <= 440V, 9A, 220VDC Coil

TeSys D Contactor, 3P(3 NO), AC-3, <= 440V, 9A, 220VDC Coil

TeSys D Contactor, 3P(3 NO), AC-3, <= 440V, 9A, 220VDC Coil

Item Number: LC1D09MD

Retail
$588.46
RRP (Inc. GST)

Product Dimensions

Width icon

Width45 mm

Height icon

Height77 mm

Depth icon

Depth95 mm

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

TeSys D

Range

TeSys

Product or component type

contactor

Sustainable offer status

Green Premium product

Warranty

18 months

Physical

[Ue] rated operational voltage

  • power circuit: <= 690 V AC 25...400 Hz
  • power circuit: <= 300 V DC
    • [Ie] rated operational current

    • 9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
    • 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
      • Electrical durability

      • 0.6 Mcycles 25 A AC-1 at Ue <= 440 V
      • 2 Mcycles 9 A AC-3 at Ue <= 440 V
        • Mounting support

        • rail
        • plate
          • Standards

          • CSA C22.2 No 14
          • EN 60947-4-1
          • EN 60947-5-1
          • IEC 60947-4-1
          • IEC 60947-5-1
          • UL 508
            • Product certifications

            • CSA
            • CCC
            • RINA
            • LROS (Lloyds register of shipping)
            • BV
            • GL
            • UL
            • GOST
            • DNV
              • Connections - terminals

              • power circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end
              • power circuit: screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end
              • power circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible with cable end
              • power circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end
              • power circuit: screw clamp terminals 1 cable(s) 1-4 mm²solid without cable end
              • power circuit: screw clamp terminals 2 cable(s) 1-4 mm²solid without cable end
              • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end
              • control circuit: screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end
              • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible with cable end
              • control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end
              • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²solid without cable end
              • control circuit: screw clamp terminals 2 cable(s) 1-4 mm²solid without cable end
                • Mechanical durability

                  30 Mcycles

                  Insulation resistance

                  > 10 MOhm for signalling circuit

                  IP degree of protection

                  IP20 front face conforming to IEC 60529

                  Ambient air temperature for operation

                • -40-60 °C
                • 60-70 °C with derating
                  • Ambient air temperature for storage

                    -60-80 °C

                    Height

                    77 mm

                    Width

                    45 mm

                    Depth

                    95 mm

                    Net weight

                    0.48 kg

                    REACh Regulation

                    Free of Substances of Very High Concern above the threshold

                    EU RoHS Directive

                    Compliant

                    Mercury free

                    Yes

                    RoHS exemption information

                    Yes

                    China RoHS Regulation

                    Product out of China RoHS scope. Substance declaration for your information

                    Environmental Disclosure

                    ENVPEP110230EN

                    Circularity Profile

                    ENVEOLI1102030EN

                    California proposition 65

                    WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov

                    Others

                    Product name

                    TeSys D

                    Device short name

                    LC1D

                    Contactor application

                  • motor control
                  • resistive load
                    • Utilisation category

                    • AC-4
                    • AC-1
                    • AC-3
                      • Poles description

                        3P

                        Pole contact composition

                        3 NO

                        Motor power kW

                      • 2.2 kW at 220...230 V AC 50/60 Hz (AC-3)
                      • 4 kW at 380...400 V AC 50/60 Hz (AC-3)
                      • 4 kW at 415...440 V AC 50/60 Hz (AC-3)
                      • 5.5 kW at 500 V AC 50/60 Hz (AC-3)
                      • 5.5 kW at 660...690 V AC 50/60 Hz (AC-3)
                      • 2.2 kW at 400 V AC 50/60 Hz (AC-4)
                        • Motor power hp

                        • 1 hp at 230/240 V AC 50/60 Hz for 1 phase motors
                        • 2 hp at 200/208 V AC 50/60 Hz for 3 phases motors
                        • 2 hp at 230/240 V AC 50/60 Hz for 3 phases motors
                        • 5 hp at 460/480 V AC 50/60 Hz for 3 phases motors
                        • 7.5 hp at 575/600 V AC 50/60 Hz for 3 phases motors
                        • 0.33 hp at 115 V AC 50/60 Hz for 1 phase motors
                          • Control circuit type

                            DC standard

                            [Uc] control circuit voltage

                            220 V DC

                            Auxiliary contact composition

                            1 NO + 1 NC

                            [Uimp] rated impulse withstand voltage

                            6 kV conforming to IEC 60947

                            Overvoltage category

                            III

                            [Ith] conventional free air thermal current

                          • 25 A (at 60 °C) for power circuit
                          • 10 A (at 60 °C) for signalling circuit
                            • Irms rated making capacity

                            • 250 A at 440 V for power circuit conforming to IEC 60947
                            • 140 A AC for signalling circuit conforming to IEC 60947-5-1
                            • 250 A DC for signalling circuit conforming to IEC 60947-5-1
                              • Rated breaking capacity

                                250 A at 440 V for power circuit conforming to IEC 60947

                                [Icw] rated short-time withstand current

                              • 105 A 40 °C - 10 s for power circuit
                              • 210 A 40 °C - 1 s for power circuit
                              • 30 A 40 °C - 10 min for power circuit
                              • 61 A 40 °C - 1 min for power circuit
                              • 100 A - 1 s for signalling circuit
                              • 120 A - 500 ms for signalling circuit
                              • 140 A - 100 ms for signalling circuit
                                • Associated fuse rating

                                • 10 A gG for signalling circuit conforming to IEC 60947-5-1
                                • 25 A gG at <= 690 V coordination type 1 for power circuit
                                • 20 A gG at <= 690 V coordination type 2 for power circuit
                                  • Average impedance

                                    2.5 mOhm - Ith 25 A 50 Hz for power circuit

                                    [Ui] rated insulation voltage

                                  • power circuit: 690 V conforming to IEC 60947-4-1
                                  • power circuit: 600 V CSA certified
                                  • power circuit: 600 V UL certified
                                  • signalling circuit: 690 V conforming to IEC 60947-1
                                  • signalling circuit: 600 V CSA certified
                                  • signalling circuit: 600 V UL certified
                                    • Power dissipation per pole

                                    • 1.56 W AC-1
                                    • 0.2 W AC-3
                                      • Protective cover

                                        with

                                        Tightening torque

                                      • power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
                                      • power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
                                      • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
                                      • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
                                        • Operating time

                                        • 53.55...72.45 ms closing
                                        • 16...24 ms opening
                                          • Safety reliability level

                                          • B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
                                          • B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
                                            • Maximum operating rate

                                              3600 cyc/h 60 °C

                                              Coil technology

                                              built-in bidirectional peak limiting diode suppressor

                                              Control circuit voltage limits

                                            • 0.1...0.25 Uc (-40-70 °C):drop-out DC
                                            • 0.7...1.25 Uc (-40-60 °C):operational DC
                                            • 1...1.25 Uc (60-70 °C):operational DC
                                              • Time constant

                                                28 ms

                                                Inrush power in W

                                                5.4-5.4 W (at 20 °C)

                                                Hold-in power consumption in W

                                                5.4-5.4 W at 20 °C

                                                Auxiliary contacts type

                                              • type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
                                              • type mirror contact 1 NC conforming to IEC 60947-4-1
                                                • Signalling circuit frequency

                                                  25...400 Hz

                                                  Minimum switching current

                                                  5 mA for signalling circuit

                                                  Minimum switching voltage

                                                  17 V for signalling circuit

                                                  Non-overlap time

                                                • 1.5 ms on de-energisation between NC and NO contact
                                                • 1.5 ms on energisation between NC and NO contact
                                                  • Contact compatibility

                                                    M4

                                                    Compatibility code

                                                    LC1D

                                                    Protective treatment

                                                    TH conforming to IEC 60068-2-30

                                                    Pollution degree

                                                    3

                                                    Operating altitude

                                                    0...3000 m

                                                    Fire resistance

                                                    850 °C conforming to IEC 60695-2-1

                                                    Flame retardance

                                                    V1 conforming to UL 94

                                                    Mechanical robustness

                                                  • vibrations contactor open: 2 Gn, 5...300 Hz
                                                  • vibrations contactor closed: 4 Gn, 5...300 Hz
                                                  • shocks contactor open: 10 Gn for 11 ms
                                                  • shocks contactor closed: 15 Gn for 11 ms
                                                    • Package 1 Weight

                                                      0.496 kg

                                                      Package 1 Height

                                                      0.5 dm

                                                      Package 1 width

                                                      0.92 dm

                                                      Package 1 Length

                                                      1.12 dm

                                                      WEEE

                                                      The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

                                                      PVC free

                                                      Yes
                                                      Show all specifications

                                                      Documents & downloads

                                                      hide show
                                                      Filter items
                                                      • All

                                                      • CAD Files and Packs

                                                      • Product Brochures

                                                      • Technical Data Catalogues

                                                      • Product Environmental

                                                      • End of Life Manual

                                                      • Installation Instruction

                                                      • Data Bulletin

                                                      • Technical illustration

                                                      • Technical Drawing

                                                      • Certificates (MSDS)

                                                      • Declaration of Conformity

                                                      Frequently Asked Questions

                                                      hide show

                                                      What is the replacement coil part number for the LC*D09 through LC*D32 and LC*DT20 through LC*DT40 TeSys contactors?

                                                      Issue:
                                                      Identifying replacement coils for tesys D non-reversing and reversing conactors

                                                      Product Line:
                                                      IEC Contactors and Starters

                                                      Environment:
                                                      Products sold and used in the United States

                                                      Cause:
                                                      Replacement coil is needed

                                                      Resolution:
                                                      DC replacement coils are not available.
                                                      AC Coils are 50/60 hertz for voltages as listed below:

                                                      Volts - Part Number
                                                      12 ____ LXD1J7
                                                      21 ____ LXD1Z7
                                                      24 ____ LXD1B7
                                                      32 ____ LXD1C7
                                                      36 ____ LXD1CC7
                                                      42 ____ LXD1D7
                                                      48 ____ LXD1E7
                                                      60 ____ LXD1EE7
                                                      100 ___ LXD1K7 ( never brought to North America )
                                                      110 ___ LXD1F7
                                                      115 ___ LXD1FE7
                                                      120 ___ LXD1G7
                                                      127 ___ LXD1FC7
                                                      200 ___ LXD1L7
                                                      208 ___ LXD1LE7
                                                      220 ___ LXD1M7
                                                      230 ___ LXD1P7
                                                      240 ___ LXD1U7
                                                      277 ___ LXD1W7
                                                      380 ___ LXD1Q7
                                                      400 ___ LXD1V7
                                                      415 ___ LXD1N7
                                                      440 ___ LXD1R7
                                                      480 ___ LXD1T7
                                                      575 ___ LXD1SC7
                                                      600 ___ LXD1X7
                                                      690 ___ LXD1Y7


                                                      Note: A contactor with an AC coil can be changed to a different AC voltage coil, IE you can take an LC1D09 with a 120VAC coil and put a 24VAC coil in it instead. An AC device cannot be switched to a DC coil, and a DC device cannot be switches to an AC coil. 

                                                      What is the maximum UL/CSA AC voltage rating of the LC1D power contacts ?

                                                      Issue:
                                                      Identifying maximum voltage of an LC1D contactor

                                                      Product Line:
                                                      TeSys D Contactors

                                                      Environment:
                                                      IEC contactors and starters used in North America

                                                      Cause:
                                                      n/a

                                                      Resolution:
                                                      IThe maximum voltage per UL and CSA is 600VAC. 
                                                       

                                                      What is the power terminal lug data for the LC1D09, LC1DT20, LC1D12, and LC1DT25 contactor?

                                                      Issue:
                                                      Power terminal lug data required for the 9 and 12 amp rated Tesys D contactors

                                                      Product Line:
                                                      IEC Contactors and Starters

                                                      Environment:
                                                      Tesys D Contactors

                                                      Resolution:
                                                      For contactors with screw clamp terminals:
                                                      stranded cable w/o cable end : One or Two #18-10 AWG per terminal.
                                                      stranded cable w/cable end: One or Two #18-10 AWG per terminal.
                                                      solid cable: One or Two #18-8 AWG per terminal.

                                                      What is the coil tolerance for Tesys D-line contactors LC1D09 - LC1D38?

                                                      Issue:
                                                      LC1D09 - LC1D38 Coil tolerance

                                                      Product Line:
                                                      Contactors and Starters, IEC

                                                      Environment:
                                                      Tesys D Contactors

                                                      Cause:
                                                      Needs the coil tolerance for Tesys D-line contactors LC1D09 - LC1D38.

                                                      Resolution:
                                                      AC single frequency coils: 50Hz and 60 Hz (-20% / +10%);
                                                      AC dual frequency coils: 50Hz (-20% / +10%) ; 60Hz (-15% / +10%)
                                                      DC standard coil for LC1D09 -D38 and LC1DT20 to DT40: (-30% / +25%)
                                                      DC standard coil for LP1D12 and D25: (-20% / +10%)
                                                      DC wide range coil for LP1D12 and D25 : (-30% to +25%)

                                                      What is the heat dissipated by the LC1D09 contactor?

                                                      Issue:
                                                      Contactors dissipate heat

                                                      Product Line:
                                                      Tesys D Contactors

                                                      Environment:
                                                      IEC Contactors and Starters

                                                      Resolution:
                                                      Total heat dissipation is 3.60 watts maximum; .20 watts dissipated across each power pole and 2 to 3 watts dissipated by the AC control coil.

                                                      What are the coil voltage codes for the LC1D09 / LC2D09 through LC1D38 / LC2D38 TeSys contactors?

                                                      Issue:
                                                      Coil Voltage suffixes for Tesys D contactors LC*D 09/38

                                                      Product Line:
                                                      IEC Contactors and Starters

                                                      Environment:
                                                      Tesys D contactors

                                                      Cause:
                                                      Selection

                                                      Resolution:
                                                      The following lists the more common voltage suffix codes for these product lines.  For a more comprehensive list and to determine compatibility with a given product, refer to the catalog below.

                                                      AC Volts ___Code     AC Volts ___Code
                                                      12 ___ J7                   208 ___ LE7
                                                      21 ___ Z7                   220 ___ M7
                                                      24 ___ B7                  230 ___ P7
                                                      32 ___ C7                  240 ___ U7
                                                      36 ___ CC7               277 ___ W7
                                                      42 ___ D7                  380 ___ Q7
                                                      48 ___ E7                   400 ___ V7
                                                      60 ___ EE7                415 ___ N7
                                                      100 ___ K7                440 ___ R7
                                                      110 ___ F7                480 ___ T7
                                                      115 ___ FE7              575 ___ SC7
                                                      120 ___ G7                600 ___ X7
                                                      127 ___ FC7              690 ___ Y7
                                                      200 ___ L7                
                                                                     
                                                      Standard Coil                Low Consumption
                                                      DC Volts ___Code          DC Volts ___Code
                                                      12 ___ JD                           5 ___ AL
                                                      24 ___ BD                         12 ___ JL
                                                      36 ___ CD                         20 ___ ZL
                                                      48 ___ ED                         24 ___ BL
                                                      60 ___ ND                         48 ___ EL
                                                      72 ___ SD                         72 ___ SL
                                                      110 ___ FD                       96 ___ DL
                                                      125 ___ GD                     110 ___ FL
                                                      220 ___ MD                    220 ___ ML
                                                      250 ___ UD                     250 ___ UL
                                                      440 ___ RD                
                                                      Show More