TeSys D Contactor, 3P(3 NO), AC-3, <= 440V, 9A, 110VDC Coil

TeSys D Contactor, 3P(3 NO), AC-3, <= 440V, 9A, 110VDC Coil

TeSys D Contactor, 3P(3 NO), AC-3, <= 440V, 9A, 110VDC Coil

Item Number: LC1D09FL

Retail
$370.87
RRP (Inc. GST)

Product Dimensions

Width icon

Width45 mm

Height icon

Height77 mm

Depth icon

Depth95 mm

See full specifications

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

TeSys D

Range

TeSys

Product or component type

contactor

Sustainable offer status

Green Premium product

Warranty

18 months

Physical

[Ue] rated operational voltage

  • power circuit: <= 690 V AC 25...400 Hz
  • power circuit: <= 300 V DC
    • [Ie] rated operational current

    • 9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
    • 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
      • Electrical durability

      • 0.6 Mcycles 25 A AC-1 at Ue <= 440 V
      • 2 Mcycles 9 A AC-3 at Ue <= 440 V
        • Mounting support

        • plate
        • rail
          • Standards

          • CSA C22.2 No 14
          • EN 60947-4-1
          • EN 60947-5-1
          • IEC 60947-4-1
          • IEC 60947-5-1
          • UL 508
            • Product certifications

            • DNV
            • GOST
            • LROS (Lloyds register of shipping)
            • BV
            • CSA
            • RINA
            • UL
            • GL
            • CCC
              • Connections - terminals

              • power circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end
              • power circuit: screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end
              • power circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible with cable end
              • power circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end
              • power circuit: screw clamp terminals 1 cable(s) 1-4 mm²solid without cable end
              • power circuit: screw clamp terminals 2 cable(s) 1-4 mm²solid without cable end
              • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end
              • control circuit: screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end
              • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible with cable end
              • control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end
              • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²solid without cable end
              • control circuit: screw clamp terminals 2 cable(s) 1-4 mm²solid without cable end
                • Mechanical durability

                  30 Mcycles

                  Insulation resistance

                  > 10 MOhm for signalling circuit

                  IP degree of protection

                  IP20 front face conforming to IEC 60529

                  Ambient air temperature for storage

                  -60-80 °C

                  Height

                  77 mm

                  Width

                  45 mm

                  Depth

                  95 mm

                  Net weight

                  0.48 kg

                  REACh free of SVHC

                  Yes

                  EU RoHS Directive

                  Compliant

                  Toxic heavy metal free

                  Yes

                  Mercury free

                  Yes

                  RoHS exemption information

                  Yes

                  China RoHS Regulation

                   Pro-active China RoHS declaration (out of China RoHS legal scope)

                  Environmental Disclosure

                  ENVPEP1501004EN

                  Circularity Profile

                  ENVEOLI1501004EN

                  Others

                  Product name

                  TeSys D

                  Device short name

                  LC1D

                  Contactor application

                • resistive load
                • motor control
                  • Utilisation category

                  • AC-1
                  • AC-3
                  • AC-4
                    • Poles description

                      3P

                      Pole contact composition

                      3 NO

                      Motor power kW

                    • 2.2 kW at 220...230 V AC 50/60 Hz (AC-3)
                    • 4 kW at 380...400 V AC 50/60 Hz (AC-3)
                    • 4 kW at 415...440 V AC 50/60 Hz (AC-3)
                    • 5.5 kW at 500 V AC 50/60 Hz (AC-3)
                    • 5.5 kW at 660...690 V AC 50/60 Hz (AC-3)
                    • 2.2 kW at 400 V AC 50/60 Hz (AC-4)
                      • Motor power hp

                      • 1 hp at 230/240 V AC 50/60 Hz for 1 phase motors
                      • 2 hp at 200/208 V AC 50/60 Hz for 3 phases motors
                      • 2 hp at 230/240 V AC 50/60 Hz for 3 phases motors
                      • 5 hp at 460/480 V AC 50/60 Hz for 3 phases motors
                      • 7.5 hp at 575/600 V AC 50/60 Hz for 3 phases motors
                      • 0.33 hp at 115 V AC 50/60 Hz for 1 phase motors
                        • Control circuit type

                          DC low consumption

                          [Uc] control circuit voltage

                          110 V DC

                          Auxiliary contact composition

                          1 NO + 1 NC

                          [Uimp] rated impulse withstand voltage

                          6 kV conforming to IEC 60947

                          Overvoltage category

                          III

                          [Ith] conventional free air thermal current

                        • 25 A (at 60 °C) for power circuit
                        • 10 A (at 60 °C) for signalling circuit
                          • Irms rated making capacity

                          • 250 A at 440 V for power circuit conforming to IEC 60947
                          • 140 A AC for signalling circuit conforming to IEC 60947-5-1
                          • 250 A DC for signalling circuit conforming to IEC 60947-5-1
                            • Rated breaking capacity

                              250 A at 440 V for power circuit conforming to IEC 60947

                              [Icw] rated short-time withstand current

                            • 105 A 40 °C - 10 s for power circuit
                            • 210 A 40 °C - 1 s for power circuit
                            • 30 A 40 °C - 10 min for power circuit
                            • 61 A 40 °C - 1 min for power circuit
                            • 100 A - 1 s for signalling circuit
                            • 120 A - 500 ms for signalling circuit
                            • 140 A - 100 ms for signalling circuit
                              • Associated fuse rating

                              • 10 A gG for signalling circuit conforming to IEC 60947-5-1
                              • 25 A gG at <= 690 V coordination type 1 for power circuit
                              • 20 A gG at <= 690 V coordination type 2 for power circuit
                                • Average impedance

                                  2.5 mOhm - Ith 25 A 50 Hz for power circuit

                                  [Ui] rated insulation voltage

                                • power circuit: 690 V conforming to IEC 60947-4-1
                                • power circuit: 600 V CSA certified
                                • power circuit: 600 V UL certified
                                • signalling circuit: 690 V conforming to IEC 60947-1
                                • signalling circuit: 600 V CSA certified
                                • signalling circuit: 600 V UL certified
                                  • Power dissipation per pole

                                  • 1.56 W AC-1
                                  • 0.2 W AC-3
                                    • Protective cover

                                      with

                                      Tightening torque

                                    • power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
                                    • power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
                                    • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
                                    • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
                                      • Operating time

                                      • 65.45...88.55 ms closing
                                      • 20...30 ms opening
                                        • Safety reliability level

                                        • B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
                                        • B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
                                          • Maximum operating rate

                                            3600 cyc/h 60 °C

                                            Coil technology

                                            built-in bidirectional peak limiting diode suppressor

                                            Time constant

                                            40 ms

                                            Inrush power in W

                                            2.4-2.4 W (at 20 °C)

                                            Hold-in power consumption in W

                                            2.4-2.4 W at 20 °C

                                            Auxiliary contacts type

                                          • type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
                                          • type mirror contact 1 NC conforming to IEC 60947-4-1
                                            • Signalling circuit frequency

                                              25...400 Hz

                                              Minimum switching current

                                              5 mA for signalling circuit

                                              Minimum switching voltage

                                              17 V for signalling circuit

                                              Non-overlap time

                                            • 1.5 ms on de-energisation between NC and NO contact
                                            • 1.5 ms on energisation between NC and NO contact
                                              • Contact compatibility

                                                M5

                                                Compatibility code

                                                LC1D

                                                Power range

                                              • 1.1-2 kW at 200-240 V 3 phases
                                              • 2.2-3 kW at 380-440 V 3 phases
                                              • 4-6 kW at 380-440 V 3 phases
                                              • 4-6 kW at 480-500 V 3 phases
                                                • Motor starter type

                                                  direct on-line contactor

                                                  Contactor coil voltage

                                                  110 V DC low consumption

                                                  Protective treatment

                                                  TH conforming to IEC 60068-2-30

                                                  Pollution degree

                                                  3

                                                  Operating altitude

                                                  3000 m without derating

                                                  Fire resistance

                                                  850 °C conforming to IEC 60695-2-1

                                                  Flame retardance

                                                  V1 conforming to UL 94

                                                  Mechanical robustness

                                                • vibrations contactor open: 2 Gn, 5...300 Hz
                                                • vibrations contactor closed: 4 Gn, 5...300 Hz
                                                • shocks contactor open: 10 Gn for 11 ms
                                                • shocks contactor closed: 15 Gn for 11 ms
                                                  • Package 1 Weight

                                                    0.332 kg

                                                    Package 1 Height

                                                    0.49 dm

                                                    Package 1 width

                                                    1.11 dm

                                                    Package 1 Length

                                                    0.89 dm

                                                    WEEE

                                                    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

                                                    PVC free

                                                    Yes
                                                    Show all specifications

                                                    Documents & downloads

                                                    hide show
                                                    Filter items
                                                    • All

                                                    • CAD Files and Packs

                                                    • Product Brochures

                                                    • Technical Data Catalogues

                                                    • End of Life Manual

                                                    • Product Environmental

                                                    • Installation Instruction

                                                    • Data Bulletin

                                                    • Certificates (MSDS)

                                                    • eTechPub

                                                    • Declaration of Conformity

                                                    Frequently Asked Questions

                                                    hide show

                                                    Where are the control coil terminals for TeSys LC1D09 to LC1D38 contactor?

                                                    Issue:
                                                    Determine the control coil terminal marking and location on LC1D09 to LC1D38 contactor

                                                    Product Line: 
                                                    Tesys D Contactors

                                                    Environment:
                                                    IEC contactors

                                                    Resolution:
                                                    The coil terminals are marked A1 and A2, you can see them on the front of the contactor on the white part (control section).  They are next to the auxiliary contact (13/14, 21/22) terminals.
                                                     

                                                    What is the altitude derating for a TeSys D-Line contactor?

                                                    Issue:​
                                                    What is the altitude derating for a TeSys D-Line contactor?

                                                    Product Line:
                                                    Digest 177 Section 18 : Contactors and Starters, IEC

                                                    Environment:
                                                    North American Products

                                                    Resolution:
                                                    The contactors are fully rated up to 3000 meters. Following are derating multipliers for altitudes above 3000 meters for both voltage and current:

                                                    Voltage
                                                    3500m x 0.90
                                                    4000m x 0.80
                                                    4500m x 0.70
                                                    5000m x 0.60

                                                    Current
                                                    3500m x 0.92
                                                    4000m x 0.90
                                                    4500m x 0.88
                                                    5000m x 0.86

                                                    For example, an LC1D80 at 5000 meters:
                                                    - The maximum rated operational voltage is 1,000V (IEC947-4) and 690V (UL/CSA). At 5000 meters it becomes 1000V x 0.6 = 600V (IEC947-4) and 690V x 0.6 = 414V (UL/CSA).
                                                    - The maximum rated operational AC3 current is 80A. At 5000 meters it becomes 80A x 0.86 = 68A.



                                                     

                                                    What is the maximum UL/CSA AC voltage rating of the LC1D power contacts ?

                                                    Issue:
                                                    Identifying maximum voltage of an LC1D contactor

                                                    Product Line:
                                                    TeSys D Contactors

                                                    Environment:
                                                    IEC contactors and starters used in North America

                                                    Cause:
                                                    n/a

                                                    Resolution:
                                                    IThe maximum voltage per UL and CSA is 600VAC. 
                                                     

                                                    Can a GV2AF3 or GV2AF4 interconnection block work on a contactor with a DC coil?

                                                    Issue:
                                                    Mounting adaptor for GV2 and LC1D contactor

                                                    Product Line:
                                                    Motor Starters and Protectors

                                                    Environment:
                                                    TeSys GV Manual Starter and Protectors
                                                    Tesys D Contactors
                                                     
                                                    Resolution:
                                                    The GV2AF3 clip has to be moved to the DC position to accommodate the contactor with a DC coil.

                                                    What is the heat dissipated by the LC1D09 contactor?

                                                    Issue:
                                                    Contactors dissipate heat

                                                    Product Line:
                                                    Tesys D Contactors

                                                    Environment:
                                                    IEC Contactors and Starters

                                                    Resolution:
                                                    Total heat dissipation is 3.60 watts maximum; .20 watts dissipated across each power pole and 2 to 3 watts dissipated by the AC control coil.


                                                     

                                                    What is the replacement coil part number for the LC*D09 through LC*D32 and LC*DT20 through LC*DT40 TeSys contactors?

                                                    Issue:
                                                    Identifying replacement coils for tesys D non-reversing and reversing conactors

                                                    Product Line:
                                                    IEC Contactors and Starters

                                                    Environment:
                                                    Products sold and used in the United States

                                                    Cause:
                                                    Replacement coil is needed

                                                    Resolution:
                                                    DC replacement coils are not available.
                                                    AC Coils are 50/60 hertz for voltages as listed below:

                                                    Volts - Part Number
                                                    12 ____ LXD1J7
                                                    21 ____ LXD1Z7
                                                    24 ____ LXD1B7
                                                    32 ____ LXD1C7
                                                    36 ____ LXD1CC7
                                                    42 ____ LXD1D7
                                                    48 ____ LXD1E7
                                                    60 ____ LXD1EE7
                                                    100 ___ LXD1K7 ( never brought to North America )
                                                    110 ___ LXD1F7
                                                    115 ___ LXD1FE7
                                                    120 ___ LXD1G7
                                                    127 ___ LXD1FC7
                                                    200 ___ LXD1L7
                                                    208 ___ LXD1LE7
                                                    220 ___ LXD1M7
                                                    230 ___ LXD1P7
                                                    240 ___ LXD1U7
                                                    277 ___ LXD1W7
                                                    380 ___ LXD1Q7
                                                    400 ___ LXD1V7
                                                    415 ___ LXD1N7
                                                    440 ___ LXD1R7
                                                    480 ___ LXD1T7
                                                    575 ___ LXD1SC7
                                                    600 ___ LXD1X7
                                                    690 ___ LXD1Y7


                                                    Note: A contactor with an AC coil can be changed to a different AC voltage coil, IE you can take an LC1D09 with a 120VAC coil and put a 24VAC coil in it instead. An AC device cannot be switched to a DC coil, and a DC device cannot be switches to an AC coil. 

                                                    What is the power terminal lug data for the LC1D09, LC1DT20, LC1D12, and LC1DT25 contactor?

                                                    Issue:
                                                    Power terminal lug data required for the 9 and 12 amp rated Tesys D contactors

                                                    Product Line:
                                                    NEMA combination starters

                                                    Environment:
                                                    Products sold and used in the United States

                                                    Resolution:
                                                    For contactors with screw clamp terminals:
                                                    stranded cable w/o cable end : One or Two #18-10 AWG per terminal.
                                                    stranded cable w/cable end: One or Two #18-10 AWG per terminal.
                                                    solid cable: One or Two #18-8 AWG per terminal.

                                                    Are the D-Line contactors rated to break DC voltages?

                                                    Issue: 
                                                    Can the TeSys D line be used to control DC loads? 

                                                    Product Line:
                                                    Tesys D contactors

                                                    Environment:
                                                    Products sold and used in the United States
                                                     
                                                    Cause:
                                                     DC power circuit
                                                     
                                                    Resolution:
                                                     
                                                    Yes, 75 VDC (125 VDC for D115 & D150) per pole which means that through a four pole device breaking 300 VDC is possible by wiring all four power poles in series. However, be aware that the device current ratings will differ according to the number of poles in series and the type of application.

                                                    Devices are suitable but not UL Listed for DC applications.

                                                    More information on their DC ratings can be found in the current TeSys Motor Control and Protection Compentns catalog: https://www.schneider-electric.us/en/download/document/MKTED210011EN/


                                                     

                                                    What is the power terminal lug data for the LC1D40, LC1D50, LC1D65, LP1D40, LP1D50, and LP1D65 contactor?

                                                    Issue:
                                                    Identifying power terminal lug data for the D2 style contactors

                                                    Product Line:
                                                    Tesys D line contactors

                                                    Environment:
                                                    Products sold and used in the United States

                                                    Cause:
                                                    Power terminal lug data required

                                                    Resolution:
                                                    For contactors with screw clamp terminals:
                                                    stranded cable w/o cable end : One #10-3 AWG or Two #10-4 AWG per terminal.
                                                    stranded cable w/cable end: One #10-4 AWG or Two #12-2 AWG per terminal.
                                                    solid cable: One #10-3 AWG or Two #10-6 AWG per terminal.

                                                    What are the coil voltage codes for the LC1D09 / LC2D09 through LC1D38 / LC2D38 TeSys contactors?

                                                    Issue:
                                                    What are the coil voltage codes for the LC1D09 / LC2D09through LC1D38 / LC2D38 TeSys contactors?

                                                    Product Line:
                                                    IEC Contactors

                                                    Environment:
                                                    Ordering

                                                    Cause:
                                                    Selection

                                                    Resolution:
                                                    The following lists the more common voltage suffix codes for these product lines.  For a more comprehensive list and to determine compatibility with a given product, refer to the catalog below.

                                                    AC Volts ___Code     AC Volts ___Code
                                                    12 ___ J7                   208 ___ LE7
                                                    21 ___ Z7                   220 ___ M7
                                                    24 ___ B7                  230 ___ P7
                                                    32 ___ C7                  240 ___ U7
                                                    36 ___ CC7               277 ___ W7
                                                    42 ___ D7                  380 ___ Q7
                                                    48 ___ E7                   400 ___ V7
                                                    60 ___ EE7                415 ___ N7
                                                    100 ___ K7                440 ___ R7
                                                    110 ___ F7                480 ___ T7
                                                    115 ___ FE7              575 ___ SC7
                                                    120 ___ G7                600 ___ X7
                                                    127 ___ FC7              690 ___ Y7
                                                    200 ___ L7                
                                                                   
                                                    Standard Coil                Low Consumption
                                                    DC Volts ___Code          DC Volts ___Code
                                                    12 ___ JD                           5 ___ AL
                                                    24 ___ BD                         12 ___ JL
                                                    36 ___ CD                         20 ___ ZL
                                                    48 ___ ED                         24 ___ BL
                                                    60 ___ ND                         48 ___ EL
                                                    72 ___ SD                         72 ___ SL
                                                    110 ___ FD                       96 ___ DL
                                                    125 ___ GD                     110 ___ FL
                                                    220 ___ MD                    220 ___ ML
                                                    250 ___ UD                     250 ___ UL
                                                    440 ___ RD                

                                                    What is the part code for the Adaptor to join the GV2P16 to a LC1D09BL

                                                    You can use GV2AF3 or GV2AF4 + LAD31

                                                    What is the difference between the LAD4TB and LAD4TBDL bi-directional peak limiting diode?

                                                    Issue:
                                                    Identifying the difference between LAD4TB and LAD4TBDL

                                                    Product Line:
                                                    IEC contactors and starters

                                                    Environment:
                                                    Products sold and used in the United States

                                                    Cause:
                                                    Identifying the difference between two similar part numbers

                                                    Resolution:
                                                    The LAD4TB is for 24V AC coils for the Tesys Series LC1D09 through LC1D38 contactors when supplied with G7 voltage code. The LAD4TBDL is 24 vdc bi-directional diode offered as a replacement if for some reason the diode supplied with the Tesys LC1D09 through LC1D38 contactors when ordered with BD or BL voltage code breaks or is no longer working.


                                                     
                                                    Show More