Contacts Block

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range

TeSys

Range of product

  • TeSys D
  • TeSys F
    • Product or component type

      time delay auxiliary contact block

      Sustainable offer status

      Green Premium product

      Warranty

      18 months

      Physical

      [Ue] rated operational voltage

      690 V AC 25...400 Hz

      Standards

    • EN 60947-5-1
    • VDE 0660
    • BS 4794
    • IEC 60947-5-1
    • NF C 63-140
      • Product certifications

      • UL
      • CSA
        • Protection type

          gG fuse 10 A

          Mechanical durability

          5 Mcycles

          Insulation resistance

          > 10 MOhm

          Connections - terminals

        • screw clamp terminals 1 cable(s) 1-2.5 mm²flexible with cable end
        • screw clamp terminals 1 cable(s) 1-2.5 mm²flexible without cable end
        • screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end
        • screw clamp terminals 2 cable(s) 1-2.5 mm²flexible without cable end
        • screw clamp terminals 1 cable(s) 1-2.5 mm²solid with cable end
        • screw clamp terminals 1 cable(s) 1-2.5 mm²solid without cable end
        • screw clamp terminals 2 cable(s) 1-2.5 mm²solid with cable end
          • Environmental characteristic

            normal environment

            IP degree of protection

            IP2x conforming to VDE 0106

            Ambient air temperature for storage

            -60-80 °C

            Ambient air temperature for operation

            -5-60 °C

            EU RoHS Directive

            Compliant

            Mercury free

            Yes

            RoHS exemption information

            Yes

            China RoHS Regulation

            Product out of China RoHS scope. Substance declaration for your information

            Environmental Disclosure

            ENVPEP110702EN

            Others

            Mounting location

            front

            Pole contact composition

            1 NO + 1 NC

            Timer type

            on delay

            Time delay range

            10...180 s

            [Ui] rated insulation voltage

          • 600 V - certifications UL
          • 690 V conforming to IEC 60947-5-1
          • 600 V - certifications CSA
            • [Ith] conventional free air thermal current

              10 A (at 60 °C)

              Irms rated making capacity

            • 140 A at <= 690 V AC conforming to IEC 60947-5-1
            • 250 A at <= 690 V DC conforming to IEC 60947-5-1
              • Permissible short-time rating

              • 100 A 60 °C 1 s
              • 120 A 60 °C 500 ms
              • 140 A 60 °C 100 ms
                • Minimum switching current

                  5 mA

                  Minimum switching voltage

                  17 V

                  Non-overlap time

                • 1.5 ms on de-energisation no overlap between NC and NO contact
                • 1.5 ms on energisation no overlap between NC and NO contact
                  • Shielding continuity terminal

                    without

                    Protective treatment

                    TH conforming to IEC 60068

                    Operating altitude

                    3000 m without derating

                    Unit Type of Package 1

                    PCE

                    Number of Units in Package 1

                    1

                    Package 1 Weight

                    74 g

                    Package 1 Height

                    5 cm

                    Package 1 width

                    5.2 cm

                    Package 1 Length

                    6.5 cm

                    WEEE

                    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                    Show all specifications

                    Documents & downloads

                    hide show
                    Filter items
                    • All

                    • CAD Files and Packs

                    • Product Brochures

                    • Technical Data Catalogues

                    • Product Environmental

                    • Installation Instruction

                    • Certificates (MSDS)

                    • Declaration of Conformity

                    Frequently Asked Questions

                    hide show

                    What is the replacement AC coil for CAD32 and CAD50 relay?

                    Issue:
                    AC coil replacement for CAD32 and CAD50

                    Product Line:
                    Relays

                    Environment:
                    Tesys CAD Control Relays

                    Cause:
                    Product selection

                    Resolution:
                    Volt = coil part number
                    12 = LXD1J7
                    21 = LXD1Z7
                    24 = LXD1B7
                    32 = LXD1C7
                    36 = LXD1CC7
                    42 = LXD1D7
                    48 = LXD1E7
                    60 = LXD1EE7
                    100 = LXD1K7
                    110 = LXD1F7
                    115 = LXD1FE7
                    120 = LXD1G7
                    127 = LXD1FC7
                    200 = LXD1L7
                    208 = LXD1LL7
                    220/230 = LXD1M7
                    230 595 21 LXD1P7
                    230/240 = LXD1U7
                    277 781 30 LXD1W7
                    380/400 = LXD1Q7
                    400 = LXD1V7
                    415 = LXD1N7
                    440 = LXD1R7
                    480 = LXD1T7
                    600 = LXD1X7
                    690 = LXD1Y7

                     

                    Will the LAD** time delay auxiliary contact module fit the D2 series pre-Tesys contactors?

                    Issue:
                    Can new accessories be used on older style contactors

                    Product Line:
                    IEC contactors and starters

                    Environment:
                    Products sold and used in the United States

                    Cause:
                    Identifying product compatibility

                    Resolution:
                    Yes, all front mount D2 and Tesys series auxiliary modules are backward forward compatible.


                     

                    Can the old D-line front mount attachments fit on the new CAD relays?

                    Issue: 
                    Can the old D-line attachments fit the new CAD relays
                     
                    Product Line:
                    IEC Contactors

                    Environment:
                    Tesys D contactors and relays
                     
                    Cause:
                    Using old accessories with new CAD relays

                    Resolution:
                     Yes, the old style front mount latch attachments, timing attachments, and auxiliary contacts will mount on the new Tesys D-line relays.

                    What is the LA2DT0 replacement timer?

                    Replacement is the LADT0 - TeSys D - time delay auxiliary contact block - 1 NO + 1 NC screw clamp terminals
                    https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=LADT0

                    Are the LAD4 RC suppressors CE marked?

                    Product Line:  
                    Tesys D line Contactors and Accessories

                    Resolution:
                    Yes these are CE marked.
                     

                    What is the part code for the Adaptor to join the GV2P16 to a LC1D09BL

                    You can use GV2AF3 or GV2AF4 + LAD31

                    What is the continuous rating for the LADT, LADS, LADR - D-Line / TeSys Time Delay Auxiliary Contact Blocks?

                    Issue:
                    What is the current and voltage rating for the LC1D timer accessories? 

                    Product Line:
                    IEC Contactors - GIC Product

                    Environment:
                    US Product

                    Cause:
                    Product Characteristics

                    Resolution:
                    They are rated NEMA A600 and Q600. 

                    This means it is rated for a maximum of 600VAC 10 amp max continuous current, and 600VDC 2.5 amp max continuous current. 

                    Will the LC1D12U7 contactor go with the LADR2 timer?

                    Yes it will. the LADR2 timer slides on the top of the LC1D12U7 contactor.

                    What is the replacement for the LA3DR2?

                    The replacement part number is LADR2

                    Is there a data jack that is silver or grey to match the Clipsal 4031VH-OM

                    Can use the Clipsal 30RJ88SMA5-SG while stock lasts

                    What is the 415v remote reset for the LRD14 overload?

                    The part number for the415VAC or DC remote reset for the LRD01...35 and the LRD313....365 is LAD703N
                    See data sheet for more information......https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=LAD703N...User-added image
                     

                    What is the difference between the LAD4TB and LAD4TBDL bi-directional peak limiting diode?

                    Issue:
                    Identifying the difference between LAD4TB and LAD4TBDL

                    Product Line:
                    IEC contactors and starters

                    Environment:
                    Products sold and used in the United States

                    Cause:
                    Identifying the difference between two similar part numbers

                    Resolution:
                    The LAD4TB is for 24V AC coils for the Tesys Series LC1D09 through LC1D38 contactors when supplied with G7 voltage code. The LAD4TBDL is 24 vdc bi-directional diode offered as a replacement if for some reason the diode supplied with the Tesys LC1D09 through LC1D38 contactors when ordered with BD or BL voltage code breaks or is no longer working.


                     
                    Show More