Specifications

hide show
Range of product
  • TeSys D
  • TeSys F
  • TeSys D control relay
    • Range
      TeSys
      Product or component type
      time delay auxiliary contact block
      Pole contact composition
      1 NO + 1 NC
      Shielding continuity terminal
      without
      Connections - terminals
    • screw clamp terminals 1 cable(s) 1-2.5 mm²flexible with cable end
    • screw clamp terminals 1 cable(s) 1-2.5 mm²flexible without cable end
    • screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end
    • screw clamp terminals 2 cable(s) 1-2.5 mm²flexible without cable end
    • screw clamp terminals 1 cable(s) 1-2.5 mm²solid with cable end
    • screw clamp terminals 1 cable(s) 1-2.5 mm²solid without cable end
    • screw clamp terminals 2 cable(s) 1-2.5 mm²solid with cable end
    • screw clamp terminals 2 cable(s) 1-2.5 mm²solid without cable end
      • Mounting location
        front
        [Ui] rated insulation voltage
      • 600 V - certifications UL
      • 690 V conforming to IEC 60947-5-1
      • 600 V - certifications CSA
        • [Ue] rated operational voltage
          690 V AC 25...400 Hz
          [Ith] conventional free air thermal current
          10 A (at 60 °C)
          Irms rated making capacity
        • 140 A at <= 690 V AC conforming to IEC 60947-5-1
        • 250 A at <= 690 V DC conforming to IEC 60947-5-1
          • Permissible short-time rating
          • 100 A 60 °C 1 s
          • 120 A 60 °C 500 ms
          • 140 A 60 °C 100 ms
            • Protection type
              gG fuse 10 A
              Associated fuse rating
              10 A gG conforming to IEC 60947-5-1
              Mechanical durability
              5 Mcycles
              Minimum switching current
              5 mA
              Minimum switching voltage
              17 V
              Non-overlap time
            • 1.5 ms on de-energisation no overlap between NC and NO contact
            • 1.5 ms on energisation no overlap between NC and NO contact
              • Timer type
                on delay
                Time delay range
                1...30 s
                Insulation resistance
                > 10 MOhm
                Environmental characteristic
                normal environment
                Standards
              • VDE 0660
              • NF C 63-140
              • IEC 60947-5-1
              • EN 60947-5-1
              • BS 4794
                • Product certifications
                • CSA
                • UL
                  • IP degree of protection
                    IP2x conforming to VDE 0106
                    Protective treatment
                    TH conforming to IEC 60068
                    Ambient air temperature for operation
                    -5-60 °C
                    Ambient air temperature for storage
                    -60-80 °C
                    Operating altitude
                    3000 m without
                    Sustainable offer status
                    Green Premium product
                    REACh Regulation
                    Reference contains Substances of Very High Concern above the threshold
                    REACh free of SVHC
                    Yes
                    EU RoHS Directive
                    Compliant
                    Mercury free
                    Yes
                    RoHS exemption information
                    Yes
                    China RoHS Regulation
                    Product out of China RoHS scope. Substance declaration for your information
                    Environmental Disclosure
                    ENVPEP110702EN
                    WEEE
                    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                    Warranty
                    18 months

                    Documents & downloads

                    hide show
                    Filter items
                    • All

                    • CAD Files and Packs

                    • Product Brochures

                    • Technical Data Catalogues

                    • Product Environmental

                    • Installation Instruction

                    • Certificates (MSDS)

                    • Declaration of Conformity

                    Frequently Asked Questions

                    hide show

                    What is the replacement for a Schneider LA2DS2 ?

                    The replacement is a LADS2. This product is interchangeable with the previous product.

                    What is the replacement AC coil for CAD32 and CAD50 relay?

                    Issue:
                    AC coil replacement for CAD32 and CAD50

                    Product Line:
                    Relays

                    Environment:
                    Tesys CAD Control Relays

                    Cause:
                    Product selection

                    Resolution:
                    Volt = coil part number
                    12 = LXD1J7
                    21 = LXD1Z7
                    24 = LXD1B7
                    32 = LXD1C7
                    36 = LXD1CC7
                    42 = LXD1D7
                    48 = LXD1E7
                    60 = LXD1EE7
                    100 = LXD1K7
                    110 = LXD1F7
                    115 = LXD1FE7
                    120 = LXD1G7
                    127 = LXD1FC7
                    200 = LXD1L7
                    208 = LXD1LL7
                    220/230 = LXD1M7
                    230 595 21 LXD1P7
                    230/240 = LXD1U7
                    277 781 30 LXD1W7
                    380/400 = LXD1Q7
                    400 = LXD1V7
                    415 = LXD1N7
                    440 = LXD1R7
                    480 = LXD1T7
                    600 = LXD1X7
                    690 = LXD1Y7

                     

                    Will the LAD** time delay auxiliary contact module fit the D2 series pre-Tesys contactors?

                    Issue:
                    Can new accessories be used on older style contactors

                    Product Line:
                    IEC contactors and starters

                    Environment:
                    Products sold and used in the United States

                    Cause:
                    Identifying product compatibility

                    Resolution:
                    Yes, all front mount D2 and Tesys series auxiliary modules are backward forward compatible.


                     

                    Will the LC1D12U7 contactor go with the LADR2 timer?

                    Yes it will. the LADR2 timer slides on the top of the LC1D12U7 contactor.

                    What is the replacement for the LA3DR2?

                    The replacement part number is LADR2

                    Can the old D-line front mount attachments fit on the new CAD relays?

                    Issue: 
                    Can the old D-line attachments fit the new CAD relays
                     
                    Product Line:
                    IEC Contactors

                    Environment:
                    Tesys D contactors and relays
                     
                    Cause:
                    Using old accessories with new CAD relays

                    Resolution:
                     Yes, the old style front mount latch attachments, timing attachments, and auxiliary contacts will mount on the new Tesys D-line relays.

                    What does LAD93217 kit come with?

                    What colour are the Dali leads?

                     Black leads with light blue ends.

                    What is the timer for TeSys contactors

                     The timer is LATD2

                    What are the wiring terminals on the IEC LRD* overload relays?

                    Product Line:
                    Tesys D line Overload Relays
                     
                    Resolution:
                    The normally closed overload contact are terminals 95 & 96; and the normally open overload contact are terminals 97 & 98.
                    T1 T2 and T3 are the load terminals. 

                    The normally closed control circuit contact will open when there is a fault, this contact is typically used in series with the control circuit. 

                    The normally open trip signal contact closes when a fault occurs which is typically used to control a pilot light, or alarm. 

                     

                    How many contacts does the electronic timer LA2KT2E have?

                    Issue:
                    LA2KT2E and LA2KT2U contacts

                    Product Line:
                    Tesys K Line Contactors

                    Environment:
                    IEC Contactor Accessories
                     
                    Resolution:
                    This module has one form C contact.
                    One normally open and one normally closed with a shared common.  Instructions are attached.

                    What is the replacement for LA1DN22 ?

                    LADN22
                    Show More