CONTACTOR TIME DELAY AUX.CONTACT BLOCK
Time delay auxiliary contact block for D range
Time delay auxiliary contact blocks TeSys LADT, 0,1s to 180s
CONTACTOR TIME DELAY AUX.CONTACT BLOCK
Time delay auxiliary contact block for D range
Time delay auxiliary contact blocks TeSys LADT, 0,1s to 180s

Contacts Block

Catalogue Number: LADR0
CONTACTOR TIME DELAY AUX.CONTACT BLOCK
Time delay auxiliary contact block for D range
Time delay auxiliary contact blocks TeSys LADT, 0,1s to 180s
CONTACTOR TIME DELAY AUX.CONTACT BLOCK
Time delay auxiliary contact block for D range
Time delay auxiliary contact blocks TeSys LADT, 0,1s to 180s
Retail
$598.32
RRP (Inc. GST)

Specifications

hide show
Range of product
  • TeSys D control relay
  • TeSys F
  • TeSys D
    • Range
      TeSys
      Product or component type
      time delay auxiliary contact block
      Pole contact composition
      1 NO + 1 NC
      Shielding continuity terminal
      without
      Connections - terminals
    • screw clamp terminals 1 cable(s) 1-2.5 mm²flexible with cable end
    • screw clamp terminals 1 cable(s) 1-2.5 mm²flexible without cable end
    • screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end
    • screw clamp terminals 2 cable(s) 1-2.5 mm²flexible without cable end
    • screw clamp terminals 1 cable(s) 1-2.5 mm²solid with cable end
    • screw clamp terminals 1 cable(s) 1-2.5 mm²solid without cable end
    • screw clamp terminals 2 cable(s) 1-2.5 mm²solid with cable end
    • screw clamp terminals 2 cable(s) 1-2.5 mm²solid without cable end
      • Mounting location
        front
        [Ui] rated insulation voltage
      • 600 V - certifications UL
      • 690 V conforming to IEC 60947-5-1
      • 600 V - certifications CSA
        • [Ue] rated operational voltage
          690 V AC 25...400 Hz
          [Ith] conventional free air thermal current
          10 A (at 60 °C)
          Irms rated making capacity
        • 140 A AC conforming to IEC 60947-5-1
        • 250 A DC conforming to IEC 60947-5-1
          • Permissible short-time rating
          • 100 A 60 °C 1 s
          • 120 A 60 °C 500 ms
          • 140 A 60 °C 100 ms
            • Protection type
              gG fuse 10 A
              Associated fuse rating
              10 A gG conforming to IEC 60947-5-1
              Mechanical durability
              5 Mcycles
              Minimum switching current
              5 mA
              Minimum switching voltage
              17 V
              Non-overlap time
            • 1.5 ms on de-energisation no overlap between NC and NO contact
            • 1.5 ms on energisation no overlap between NC and NO contact
              • Timer type
                off delay
                Time delay range
                0.1...3 s
                Insulation resistance
                > 10 MOhm
                Environmental characteristic
                normal environment
                Standards
              • NF C 63-140
              • EN 60947-5-1
              • VDE 0660
              • BS 4794
              • IEC 60947-5-1
                • Product certifications
                • CSA
                • UL
                  • IP degree of protection
                    IP2x conforming to VDE 0660
                    Protective treatment
                    TH conforming to IEC 60068
                    Ambient air temperature for operation
                    -5-60 °C
                    Ambient air temperature for storage
                    -60-80 °C
                    Operating altitude
                    3000 m
                    Unit Type of Package 1
                    PCE
                    Number of Units in Package 1
                    1
                    Package 1 Weight
                    76 g
                    Package 1 Height
                    5 cm
                    Package 1 width
                    5.2 cm
                    Package 1 Length
                    6.5 cm
                    Unit Type of Package 2
                    BB1
                    Number of Units in Package 2
                    10
                    Package 2 Weight
                    1.76 kg
                    Package 2 Height
                    5.4 cm
                    Package 2 width
                    13.2 cm
                    Package 2 Length
                    24.2 cm
                    Unit Type of Package 3
                    S03
                    Number of Units in Package 3
                    140
                    Package 3 Weight
                    11.099 kg
                    Package 3 Height
                    30 cm
                    Package 3 width
                    30 cm
                    Package 3 Length
                    40 cm
                    Sustainable offer status
                    Green Premium product
                    EU RoHS Directive
                    Compliant
                    Mercury free
                    Yes
                    RoHS exemption information
                    Yes
                    China RoHS Regulation
                    Product out of China RoHS scope. Substance declaration for your information
                    Environmental Disclosure
                    ENVPEP110702EN
                    WEEE
                    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                    Warranty
                    18 months

                    Documents & downloads

                    hide show
                    Filter items
                    • All

                    • CAD Files and Packs

                    • Product Brochures

                    • Technical Data Catalogues

                    • Product Environmental

                    • Installation Instruction

                    • Certificates (MSDS)

                    • Declaration of Conformity

                    Frequently Asked Questions

                    hide show

                    What is the replacement AC coil for CAD32 and CAD50 relay?

                    Issue:
                    AC coil replacement for CAD32 and CAD50

                    Product Line:
                    Relays

                    Environment:
                    Tesys CAD Control Relays

                    Cause:
                    Product selection

                    Resolution:
                    Volt = coil part number
                    12 = LXD1J7
                    21 = LXD1Z7
                    24 = LXD1B7
                    32 = LXD1C7
                    36 = LXD1CC7
                    42 = LXD1D7
                    48 = LXD1E7
                    60 = LXD1EE7
                    100 = LXD1K7
                    110 = LXD1F7
                    115 = LXD1FE7
                    120 = LXD1G7
                    127 = LXD1FC7
                    200 = LXD1L7
                    208 = LXD1LL7
                    220/230 = LXD1M7
                    230 595 21 LXD1P7
                    230/240 = LXD1U7
                    277 781 30 LXD1W7
                    380/400 = LXD1Q7
                    400 = LXD1V7
                    415 = LXD1N7
                    440 = LXD1R7
                    480 = LXD1T7
                    600 = LXD1X7
                    690 = LXD1Y7

                     

                    Will the LAD** time delay auxiliary contact module fit the D2 series pre-Tesys contactors?

                    Issue:
                    Can new accessories be used on older style contactors

                    Product Line:
                    IEC contactors and starters

                    Environment:
                    Products sold and used in the United States

                    Cause:
                    Identifying product compatibility

                    Resolution:
                    Yes, all front mount D2 and Tesys series auxiliary modules are backward forward compatible.


                     

                    Will the LC1D12U7 contactor go with the LADR2 timer?

                    Yes it will. the LADR2 timer slides on the top of the LC1D12U7 contactor.

                    What is the replacement for the LA3DR2?

                    The replacement part number is LADR2

                    Can the old D-line front mount attachments fit on the new CAD relays?

                    Issue: 
                    Can the old D-line attachments fit the new CAD relays
                     
                    Product Line:
                    IEC Contactors

                    Environment:
                    Tesys D contactors and relays
                     
                    Cause:
                    Using old accessories with new CAD relays

                    Resolution:
                     Yes, the old style front mount latch attachments, timing attachments, and auxiliary contacts will mount on the new Tesys D-line relays.

                    What is the LA2DT0 replacement timer?

                    Replacement is the LADT0 - TeSys D - time delay auxiliary contact block - 1 NO + 1 NC screw clamp terminals
                    https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=LADT0

                    What is the continuous rating for the LADT, LADS, LADR - D-Line / TeSys Time Delay Auxiliary Contact Blocks?

                    Issue:
                    What is the current and voltage rating for the LC1D timer accessories? 

                    Product Line:
                    IEC Contactors - GIC Product

                    Environment:
                    US Product

                    Cause:
                    Product Characteristics

                    Resolution:
                    They are rated NEMA A600 and Q600. 

                    This means it is rated for a maximum of 600VAC 10 amp max continuous current, and 600VDC 2.5 amp max continuous current. 

                    What is the part code for the Adaptor to join the GV2P16 to a LC1D09BL

                    You can use GV2AF3 or GV2AF4 + LAD31

                    Does the LAD703 side or top mount to the overload

                     It is side mount

                    LAD9R3 kit components

                    Issue:
                    What does the LAD9R3 reversing interlock kit include

                    Product Line:
                    LC1D contactors
                    LC2D reversing contactors

                    Environment:
                    US Product

                    Cause:
                    It is necessary to ensure that this kit will include all of the pieces an End User would need.

                    Resolution:
                    This kit includes a mechanical interlock (LAD4CM) as well as reversing power connections (LA9D65A69).

                    What is the code for an off delay auxiliary contact block for Tesys contactors?

                    The code is LADR2. This is a 0.1-30s off Delay

                    Will a single circuit auxiliary contact block, like a LADN10 or LADN01, fit onto the Tesys D09-D38 amp contactors?

                    Issue:
                    Identifying auxiliary contact blocks for Tesys D contactors

                    Product Line:
                    IEC contactors and starters

                    Environment:
                    Products sold and used in the United States

                    Cause:
                    single auxiliary contact block needed for use on a Tesys D line contactor

                    Resolution:
                    No, the single pole contact block will not fit . A LADN11,LADN20, LADN02 etc will fit. Anything with 2 auxiliary contacts in one block will fit.
                     
                    Show More