TeSys D Auxiliary Contact Block, 4 NC, Screw Clamps Terminals

TeSys D Auxiliary Contact Block, 4 NC, Screw Clamps Terminals

TeSys D Auxiliary Contact Block, 4 NC, Screw Clamps Terminals

Item Number: LADN04

Retail
$155.18
RRP (Inc. GST)

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range

TeSys

Range of product

TeSys D

Product or component type

auxiliary contact block

Sustainable offer status

Green Premium product

Warranty

18 months

Physical

Range compatibility

  • TeSys LC1D
  • TeSys CAD
  • TeSys LC1F
  • TeSys CR1F
    • [Ue] rated operational voltage

      690 V AC 25...400 Hz

      Standards

    • EN/IEC 60947-5-1
    • UL 60947-5-1
    • CSA C22.2 No 60947-5-1
    • GB/T 14048.5
      • Product certifications

      • IECEE CB Scheme
      • UL
      • CSA
      • CCC
      • EAC
        • Protection type

          gG fuse 10 A

          Mechanical durability

          30 Mcycles

          Insulation resistance

          > 10 MOhm

          Connections - terminals

        • screw clamp terminals 1 cable(s) 1-2.5 mm²flexible with cable end
        • screw clamp terminals 1 cable(s) 1-2.5 mm²flexible without cable end
        • screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end
        • screw clamp terminals 2 cable(s) 1-2.5 mm²flexible without cable end
        • screw clamp terminals 1 cable(s) 1-2.5 mm²solid
        • screw clamp terminals 2 cable(s) 1-2.5 mm²solid
          • Net weight

            0.05 kg

            Environmental characteristic

            normal environment

            IP degree of protection

            IP20 conforming to IEC 60529

            Ambient air temperature for storage

            -60-80 °C

            Ambient air temperature for operation

            -5-60 °C

            REACh free of SVHC

            Yes

            EU RoHS Directive

            Compliant

            Toxic heavy metal free

            Yes

            Mercury free

            Yes

            RoHS exemption information

            Yes

            China RoHS Regulation

             Pro-active China RoHS declaration (out of China RoHS legal scope)

            Environmental Disclosure

            ENVPEP110807EN_V1

            Others

            Device short name

            LADN

            Specific use

            general

            Mounting location

            front

            Pole contact composition

            4 NC

            Auxiliary contacts operation

            instantaneous

            [Ui] rated insulation voltage

          • 690 V conforming to IEC 60947-5-1
          • 600 V - certifications CSA
          • 600 V - certifications UL
            • [Ith] conventional free air thermal current

              10 A (at 60 °C)

              Irms rated making capacity

            • 140 A AC conforming to IEC 60947-5-1
            • 250 A DC conforming to IEC 60947-5-1
              • Permissible short-time rating

              • 100 A 60 °C 1 s
              • 120 A 60 °C 500 ms
              • 140 A 60 °C 100 ms
                • Minimum switching current

                  5 mA

                  Minimum switching voltage

                  17 V

                  Non-overlap time

                • 1.5 ms on de-energisation no overlap between NC and NO contact
                • 1.5 ms on energisation no overlap between NC and NO contact
                  • Tightening torque

                    1.7 N.m

                    Shielding continuity terminal

                    without

                    Protective treatment

                    TH conforming to IEC 60068

                    Operating altitude

                    3000 m

                    Unit Type of Package 1

                    PCE

                    Number of Units in Package 1

                    1

                    Package 1 Weight

                    62 g

                    Package 1 Height

                    4.2 cm

                    Package 1 width

                    4.8 cm

                    Package 1 Length

                    5 cm

                    Unit Type of Package 2

                    BB1

                    Number of Units in Package 2

                    10

                    Package 2 Weight

                    624 g

                    Package 2 Height

                    4.8 cm

                    Package 2 width

                    8.6 cm

                    Package 2 Length

                    25.5 cm

                    Unit Type of Package 3

                    S03

                    Number of Units in Package 3

                    160

                    Package 3 Weight

                    10.398 kg

                    Package 3 Height

                    30 cm

                    Package 3 width

                    30 cm

                    Package 3 Length

                    40 cm

                    WEEE

                    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                    Show all specifications

                    Documents & downloads

                    hide show
                    Filter items
                    • All

                    • CAD Files and Packs

                    • Product Brochures

                    • Technical Data Catalogues

                    • Product Environmental

                    • Installation Instruction

                    • Declaration of Conformity

                    Frequently Asked Questions

                    hide show

                    What is the replacement AC coil for CAD32 and CAD50 relay?

                    Issue:
                    AC coil replacement for CAD32 and CAD50

                    Product Line:
                    Relays

                    Environment:
                    Tesys CAD Control Relays

                    Cause:
                    Product selection

                    Resolution:
                    Volt = coil part number
                    12 = LXD1J7
                    21 = LXD1Z7
                    24 = LXD1B7
                    32 = LXD1C7
                    36 = LXD1CC7
                    42 = LXD1D7
                    48 = LXD1E7
                    60 = LXD1EE7
                    100 = LXD1K7
                    110 = LXD1F7
                    115 = LXD1FE7
                    120 = LXD1G7
                    127 = LXD1FC7
                    200 = LXD1L7
                    208 = LXD1LL7
                    220/230 = LXD1M7
                    230 595 21 LXD1P7
                    230/240 = LXD1U7
                    277 781 30 LXD1W7
                    380/400 = LXD1Q7
                    400 = LXD1V7
                    415 = LXD1N7
                    440 = LXD1R7
                    480 = LXD1T7
                    600 = LXD1X7
                    690 = LXD1Y7

                     

                    What is the Difference between LADN206 and LADN20?

                    LADN206 has 2N/O Lugs ring terminal
                    LADN20 has 2 N/O - screw-clamps terminals
                    Rest of the specifications are the same.

                    What is the replacement for LA1DN04?

                    The replacement for LA1DN04 is LADN04

                    LADN04 
                    TeSys D - auxiliary contact block - 4 NC - screw clamp terminals
                    Fore more information see:https://www.schneider-electric.com.au/en/product-range-selector/665-tesys-f/?p_url=http%3A%2F%2Fwww.ops-ecat.schneider-electric.com%2Fecatalogue%2Fbrowse.do%3Fel_typ%3Dproduct%26cat_id%3DBU_POW_665_L3_Z010%26conf%3Dbasket%26prd_id%3DLADN04%26scp_id%3DZ010

                    Will a single circuit auxiliary contact block, like a LADN10 or LADN01, fit onto the Tesys D09-D38 amp contactors?

                    Issue:
                    Identifying auxiliary contact blocks for Tesys D contactors

                    Product Line:
                    IEC contactors and starters

                    Environment:
                    Products sold and used in the United States

                    Cause:
                    single auxiliary contact block needed for use on a Tesys D line contactor

                    Resolution:
                    No, the single pole contact block will not fit . A LADN11,LADN20, LADN02 etc will fit. Anything with 2 auxiliary contacts in one block will fit.
                     

                    ETSNZ - Can Tesys F range contactors be used in safety applications?

                    According to IEC60947-4-1 appendix F, mirror contact is one of the means necessary to ensure safety for contactors
                    (in the standard "...mirror contact should not be relied upon exclusively as a means to ensure safety..." ).

                    TeSys F contactors do not include internal mirror contacts. So we, Schneider, do not actively promote TeSys F as a contactor for safety applications.
                    However, TeSys F can be fitted with auxiliary contacts add-on blocks. For some of these blocks LADN01, LADN02, LADN04, LADN11, LADN22, LADN31 and LADN13, a NC auxiliary contact has been recognised by VDE as mirror contact. This allows to use TeSys F in safety applications.
                    Attached are the VDE Certificates recognising the NC auxiliary contact with the blocks mentioned above as mirror contact.

                    To sum up and give clear answers to TeSys F and safety applications ;
                    1. If Tesys F contactor can be used for safety applications?

                    Yes, it can be used if, this is mandatory, it is fitted with one the above mentioned add-on blocks. VDE Certificate recognising the auxiliary contact as mirror can be provided.


                    2. When asked, can we answer that Tesys F have mirror contact, provided by auxiliary contact blocks?

                    Yes for the above mentioned add-on blocks and with the VDE Certificate

                    Can the old D-line front mount attachments fit on the new CAD relays?

                    Issue: 
                    Can the old D-line attachments fit the new CAD relays
                     
                    Product Line:
                    IEC Contactors

                    Environment:
                    Tesys D contactors and relays
                     
                    Cause:
                    Using old accessories with new CAD relays

                    Resolution:
                     Yes, the old style front mount latch attachments, timing attachments, and auxiliary contacts will mount on the new Tesys D-line relays.

                    What is the replacement for LA1DN22 ?

                    LADN22

                    Does the LAD703 side or top mount to the overload

                     It is side mount

                    What is the part code for a 630A Contactor with 230V coil

                     The part codes you need LC1F630 + LX1FL220 + LADN11

                    What is the auxiliary 3 x N/O and 1 x N/C front fitted needed for a LC1D5011 contactor

                    The Auxiliary is an LADN31

                    What is the part number for remote module for LR97D07?

                    We can use
                    LAD703 .

                    What is the part code for a 320A 3P Contactor 230V interlock aux 2 n/o 2n/c

                    The part codes are LC1F330 coil + LX1FH2402 interlock  + LA9FJ970 aux  = LADN22
                    Show More