Instantaneous auxiliary contact block LADN, 1 contact, with connection by screw clamps terminals

TeSys D Auxiliary Contact Block, 1 NC, Screw Clamps Terminals

Catalogue Number: LADN01
Instantaneous auxiliary contact block LADN, 1 contact, with connection by screw clamps terminals
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Range of product
TeSys D
Range
TeSys
Device short name
LADN
Product or component type
auxiliary contact block
Range compatibility
  • TeSys CAD
  • TeSys LC1D
  • TeSys LC1F
  • TeSys CR1F
    • Auxiliary contacts operation
      instantaneous
      Pole contact composition
      1 NC
      Shielding continuity terminal
      without
      Connections - terminals
    • screw clamp terminals 1 cable(s) 1-2.5 mm²flexible with cable end
    • screw clamp terminals 1 cable(s) 1-2.5 mm²flexible without cable end
    • screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end
    • screw clamp terminals 2 cable(s) 1-2.5 mm²flexible without cable end
    • screw clamp terminals 1 cable(s) 1-2.5 mm²solid
    • screw clamp terminals 2 cable(s) 1-2.5 mm²solid
      • Mounting location
        front
        [Ui] rated insulation voltage
      • 690 V conforming to IEC 60947-5-1
      • 600 V - certifications CSA
      • 600 V - certifications UL
        • [Ue] rated operational voltage
          690 V AC 25...400 Hz
          [Ith] conventional free air thermal current
          10 A (at 60 °C)
          Irms rated making capacity
        • 140 A AC conforming to IEC 60947-5-1
        • 250 A DC conforming to IEC 60947-5-1
          • Permissible short-time rating
          • 100 A 60 °C 1 s
          • 120 A 60 °C 500 ms
          • 140 A 60 °C 100 ms
            • Protection type
              gG fuse 10 A
              Mechanical durability
              30 Mcycles
              Minimum switching current
              5 mA
              Minimum switching voltage
              17 V
              Non-overlap time
            • 1.5 ms on de-energisation no overlap between NC and NO contact
            • 1.5 ms on energisation no overlap between NC and NO contact
              • Insulation resistance
                > 10 MOhm
                Tightening torque
                1.7 N.m
                Net weight
                0.02 kg
                Environmental characteristic
                normal environment
                Standards
              • EN/IEC 60947-5-1
              • UL 60947-5-1
              • CSA C22.2 No 60947-5-1
              • GB/T 14048.5
                • Specific use
                  general
                  Product certifications
                • IECEE CB Scheme
                • UL
                • CSA
                • CCC
                • EAC
                  • IP degree of protection
                    IP20 conforming to IEC 60529
                    Protective treatment
                    TH conforming to IEC 60068
                    Ambient air temperature for operation
                    -5-60 °C
                    Ambient air temperature for storage
                    -60-80 °C
                    Operating altitude
                    3000 m
                    Sustainable offer status
                    Green Premium product
                    REACh Regulation
                    Free of Substances of Very High Concern above the threshold
                    REACh free of SVHC
                    Yes
                    EU RoHS Directive
                    Compliant
                    Toxic heavy metal free
                    Yes
                    Mercury free
                    Yes
                    RoHS exemption information
                    Yes
                    China RoHS Regulation
                     Pro-active China RoHS declaration (out of China RoHS legal scope)
                    Environmental Disclosure
                    ENVPEP110807EN_V1
                    WEEE
                    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                    Warranty
                    18 months

                    Documents & downloads

                    hide show
                    Filter items
                    • All

                    • Product Brochures

                    • Technical Data Catalogues

                    • Product Environmental

                    • Installation Instruction

                    • Declaration of Conformity

                    Frequently Asked Questions

                    hide show

                    What is the replacement AC coil for CAD32 and CAD50 relay?

                    Issue:
                    AC coil replacement for CAD32 and CAD50

                    Product Line:
                    Relays

                    Environment:
                    Tesys CAD Control Relays

                    Cause:
                    Product selection

                    Resolution:
                    Volt = coil part number
                    12 = LXD1J7
                    21 = LXD1Z7
                    24 = LXD1B7
                    32 = LXD1C7
                    36 = LXD1CC7
                    42 = LXD1D7
                    48 = LXD1E7
                    60 = LXD1EE7
                    100 = LXD1K7
                    110 = LXD1F7
                    115 = LXD1FE7
                    120 = LXD1G7
                    127 = LXD1FC7
                    200 = LXD1L7
                    208 = LXD1LL7
                    220/230 = LXD1M7
                    230 595 21 LXD1P7
                    230/240 = LXD1U7
                    277 781 30 LXD1W7
                    380/400 = LXD1Q7
                    400 = LXD1V7
                    415 = LXD1N7
                    440 = LXD1R7
                    480 = LXD1T7
                    600 = LXD1X7
                    690 = LXD1Y7

                     

                    What is the Difference between LADN206 and LADN20?

                    LADN206 has 2N/O Lugs ring terminal
                    LADN20 has 2 N/O - screw-clamps terminals
                    Rest of the specifications are the same.

                    Will a single circuit auxiliary contact block, like a LADN10 or LADN01, fit onto the Tesys D09-D38 amp contactors?

                    Issue:
                    Identifying auxiliary contact blocks for Tesys D contactors

                    Product Line:
                    IEC contactors and starters

                    Environment:
                    Products sold and used in the United States

                    Cause:
                    single auxiliary contact block needed for use on a Tesys D line contactor

                    Resolution:
                    No, the single pole contact block will not fit . A LADN11,LADN20, LADN02 etc will fit. Anything with 2 auxiliary contacts in one block will fit.
                     

                    ETSNZ - Can Tesys F range contactors be used in safety applications?

                    According to IEC60947-4-1 appendix F, mirror contact is one of the means necessary to ensure safety for contactors
                    (in the standard "...mirror contact should not be relied upon exclusively as a means to ensure safety..." ).

                    TeSys F contactors do not include internal mirror contacts. So we, Schneider, do not actively promote TeSys F as a contactor for safety applications.
                    However, TeSys F can be fitted with auxiliary contacts add-on blocks. For some of these blocks LADN01, LADN02, LADN04, LADN11, LADN22, LADN31 and LADN13, a NC auxiliary contact has been recognised by VDE as mirror contact. This allows to use TeSys F in safety applications.
                    Attached are the VDE Certificates recognising the NC auxiliary contact with the blocks mentioned above as mirror contact.

                    To sum up and give clear answers to TeSys F and safety applications ;
                    1. If Tesys F contactor can be used for safety applications?

                    Yes, it can be used if, this is mandatory, it is fitted with one the above mentioned add-on blocks. VDE Certificate recognising the auxiliary contact as mirror can be provided.


                    2. When asked, can we answer that Tesys F have mirror contact, provided by auxiliary contact blocks?

                    Yes for the above mentioned add-on blocks and with the VDE Certificate

                    Can the old D-line front mount attachments fit on the new CAD relays?

                    Issue: 
                    Can the old D-line attachments fit the new CAD relays
                     
                    Product Line:
                    IEC Contactors

                    Environment:
                    Tesys D contactors and relays
                     
                    Cause:
                    Using old accessories with new CAD relays

                    Resolution:
                     Yes, the old style front mount latch attachments, timing attachments, and auxiliary contacts will mount on the new Tesys D-line relays.

                    What is the part code for a 630A Contactor with 230V coil

                     The part codes you need LC1F630 + LX1FL220 + LADN11

                    What is the auxiliary 3 x N/O and 1 x N/C front fitted needed for a LC1D5011 contactor

                    The Auxiliary is an LADN31

                    What is the replacement for LA1DN22 ?

                    LADN22

                    Need the spare part code for a DOL starter LE1D12, only need the arm behind push button

                     The part code is LAD9091

                    Can the single pole LA1DN and LADN auxiliary contact module be mounted on the TeSys contactors?

                    ISSUE
                    Can the single pole LA1DN and LADN auxiliary contact module be mounted on the TeSys contactors?
                    PRODUCT LINE
                    Auxiliary contacts for the Tesys D line
                    ENVIRONMENT
                    Tesys D-Line and Tesys F
                    CAUSE
                    Fit
                    RESOLUTION
                    These contacts will only fit on the following contactors:
                    Front mount only for LC1D40 through LC1D115 devices and LC1D40A - LC1D65A.
                    Left side mount only to LC1F contactors
                    CTA-ID : 2002751

                    Does the LAD703 side or top mount to the overload

                     It is side mount

                    What is the difference between LAD703 and LA7D03

                    Issue:
                    Identifying differences between two similar part numbers

                    Product Line:
                    IEC contactors and starters

                    Environment:
                    Products sold and used in the United States

                    Cause:
                    Identifying differences between two similar part numbers

                    Resolution:
                    Both will remotely stop (trip) or electrically reset the overload, however;
                    LAD703 is used on Tesys overload LRD01 through LRD35 and LR3D01 to LR3D35.
                    LA7D03 is used on all other LR*D overload relays other than LRD01 to LRD35 and LR3D01 to LR3D35.


                     
                    Show More