Specifications

hide show
Range
TeSys
Device short name
LAD
Product or component type
pre-wired connector
Accessory / separate part category
connection accessory
Product compatibility
  • LR3D01...D35
  • LC1D09...D18
  • LRD01...35
    • Net weight
      0.002 kg
      Quantity per set
      set of 10
      Compatibility code
      LAD
      REACh Regulation
      Free of Substances of Very High Concern above the threshold
      REACh free of SVHC
      Yes
      EU RoHS Directive
      Compliant
      Toxic heavy metal free
      Yes
      Mercury free
      Yes
      RoHS exemption information
      Yes
      China RoHS Regulation
       Pro-active China RoHS declaration (out of China RoHS legal scope)
      Warranty
      18 months

      Frequently Asked Questions

      hide show

      How to use LRD01…35 LRD33•• & LRD43•• and LRD33** as an indepentent relay?

      The LRD relays has a solid tag to be used with LC1D** contactors. If you are not using LC1D contactors then using the following accessories you can terminate cable directly.

      For LRD01…35 use the following part: LAD7B106
      For LRD33•• & LRD43•• (3) use the following part: LA7D3064

      In regards to LAD5C11 LAD5C31 LAD5C12 LAD5C32 What is the maximum kW range that TeSys SoLink can be used with motor starter combination?

      TeSys SoLink is the connection module to connect GV2/GV3 motor circuit breakers to associated contactors and can be used with GV2 / GV3 breakers up to 30kW.
      For more information please visit the Link provided
      https://www.schneider-electric.com.au/australia/en/products-services/offer-updates/news-viewer.page?c_filepath=/templatedata/Content/News/data/en/local/automation_control/general_information/2014/10/20141024_tesys_solink_integration_system.xml

      In regards to LAD5C11 LAD5C31 LAD5C12 LAD5C32 SoLink What is the maximum number of motor starters that can be connected and controlled with each logic controller?

      Each TM3 I/O module is able to monitor and control up to 4 motor starters and up to 56 motor starters can be connected to logic controller.
      For more information aboput this range please Visit the Schneider website on the link provided
      https://www.schneider-electric.com.au/australia/en/products-services/offer-updates/news-viewer.page?c_filepath=/templatedata/Content/News/data/en/local/automation_control/general_information/2014/10/20141024_tesys_solink_integration_system.xml

      In regards to LAD5C11 LAD5C31 LAD5C12 LAD5C32 SoLink , Can TeSys SoLink be used with AC control supply?

      TeSys SoLink is suitable for 24VDC control supply; the TM3 I/O module provides the 24V DC control voltage to the motor starter.
      For more information on this range please visit the Schneider electric web site on the link provided
      https://www.schneider-electric.com.au/australia/en/products-services/offer-updates/news-viewer.page?c_filepath=/templatedata/Content/News/data/en/local/automation_control/general_information/2014/10/20141024_tesys_solink_integration_system.xml

      Does the LAD703 side or top mount to the overload

       It is side mount

      What is the part code for a 630A Contactor with 230V coil

       The part codes you need LC1F630 + LX1FL220 + LADN11

      What is the auxiliary 3 x N/O and 1 x N/C front fitted needed for a LC1D5011 contactor

      The Auxiliary is an LADN31

      Is there a retrofit plate available for replacement of LC1D40-D65 contactors with the LC1D40A-65A contactors?

      Use a LAD7X3 retrofit plate.


      CTA-ID : 2053453

      Is the LAD7B10 a UL and CSA Recognized Component?

      Issue:
      Is the LAD7B10 a UL or CSA recognized component?

      Product Line:
      IEC Overload Mounting Kit

      Environment:
      IEC Contactors

      Cause:
      Clarify CSA and UL listing for IEC components

      Resolution:
      As of 6/30/2016 this device has been UL component recongnized. This device has not been CSA recognized

      Key words LAD7B10, UL, CSA, separate mounting

      Case Subject:
      LAD7B10

      GV2 Adapter Plate Mounting

      Two lock elements come with LAD311. The first one, already mounted on LAD311 when delivered is suitable for almost all cases of LC1D contactor. However, depending on the type of coil of the contactor (DC or AC), this element shall be mounted in one position for DC or turned by 180° around an horizontal axis for AC coil contactor. Note that on the lateral face of this elements the markings “DC” or “AC” mounted upwards indicates the right position to be used. The second LAD311 lock element shall be used when mounting contactors LC1D09 to LC1D18 with screw clamp. In this case, this element shall be mounted on LAD311 instead of the first one which can be scrapped away.

      See attached document for reference. 

      Will the LAD7B10 or the LAD7B106 work on the Pre-Tesys D line LR2D15*** overload relays?

      Issue:
      Separate mount block needed for older style overload relay

      Product Line:
      IEC contactors and starters

      Environment:
      North American Products

      Resolution:
      No. These are a different design and will not work with the pre - Tesys overload relays.


       

      What is the replacement AC coil for CAD32 and CAD50 relay?

      Issue:
      AC coil replacement for CAD32 and CAD50

      Product Line:
      Relays

      Environment:
      Tesys CAD Control Relays

      Cause:
      Product selection

      Resolution:
      Volt = coil part number
      12 = LXD1J7
      21 = LXD1Z7
      24 = LXD1B7
      32 = LXD1C7
      36 = LXD1CC7
      42 = LXD1D7
      48 = LXD1E7
      60 = LXD1EE7
      100 = LXD1K7
      110 = LXD1F7
      115 = LXD1FE7
      120 = LXD1G7
      127 = LXD1FC7
      200 = LXD1L7
      208 = LXD1LL7
      220/230 = LXD1M7
      230 595 21 LXD1P7
      230/240 = LXD1U7
      277 781 30 LXD1W7
      380/400 = LXD1Q7
      400 = LXD1V7
      415 = LXD1N7
      440 = LXD1R7
      480 = LXD1T7
      600 = LXD1X7
      690 = LXD1Y7

       
      Show More