Accessorie for thermal overload relay
TERMINAL BLOCK FOR SEPARATE MOUNT CL 20
TERMINAL BLOCK FOR SEPARATE MOUNT CL 20
Accessorie for thermal overload relay
TERMINAL BLOCK FOR SEPARATE MOUNT CL 20
TERMINAL BLOCK FOR SEPARATE MOUNT CL 20

TeSys, Thermal Overload Relays, Terminal Block

Catalogue Number: LAD7B205
Accessorie for thermal overload relay
TERMINAL BLOCK FOR SEPARATE MOUNT CL 20
TERMINAL BLOCK FOR SEPARATE MOUNT CL 20
Accessorie for thermal overload relay
TERMINAL BLOCK FOR SEPARATE MOUNT CL 20
TERMINAL BLOCK FOR SEPARATE MOUNT CL 20
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Range
TeSys
Product or component type
terminal block
Device short name
LAD
Accessory / separate part category
connection accessory
Product compatibility
  • LR9D..
  • LRD..L
  • LR3D..L
    • Height
      85 mm
      Width
      45 mm
      Depth
      86.1 mm
      Compatibility code
      LAD
      Sustainable offer status
      Green Premium product
      REACh Regulation
      Free of Substances of Very High Concern above the threshold
      REACh free of SVHC
      Yes
      EU RoHS Directive
      Compliant
      Toxic heavy metal free
      Yes
      Mercury free
      Yes
      RoHS exemption information
      Yes
      China RoHS Regulation
       Pro-active China RoHS declaration (out of China RoHS legal scope)
      Environmental Disclosure
      ENVPEP111213EN_V1
      Circularity Profile
      N/A
      WEEE
      The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
      California proposition 65
      WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.gov

      Documents & downloads

      hide show
      Filter items
      • All

      • CAD Files and Packs

      • Product Brochures

      • Movies

      • Technical Data Catalogues

      • Catalog Page

      • Technical Leaflet

      • Installation Instruction

      • End of Life Manual

      • Product Environmental

      • Data Bulletin

      • Operating Manuals

      • Declaration of Conformity

      • Certificates (MSDS)

      • Marine Certificate

      • White Paper

      Frequently Asked Questions

      hide show

      Is the LAD7B10 a UL and CSA Recognized Component?

      Issue:
      Is the LAD7B10 a UL or CSA recognized component?

      Product Line:
      IEC Overload Mounting Kit

      Environment:
      IEC Contactors

      Cause:
      Clarify CSA and UL listing for IEC components

      Resolution:
      As of 6/30/2016 this device has been UL component recongnized. This device has not been CSA recognized

      Key words LAD7B10, UL, CSA, separate mounting

      Case Subject:
      LAD7B10

      What is the Din rail terminal block to suit the LRD12?

      The LAD7B106 fits the LRD01 to LRD35 range.
       

      What is the difference between the LA7D305 and LAD7305, remote control reset mechanism by flexible cable?

      Issue:
      Identifying differences between two similar part numbers.

      Product Line:
      IEC contactors and starters

      Environment:
      Products sold and used in the United States

      Cause:
      Choosing the correct part number

      Resolution:
      LAD7305 is for use on LRD01 to LRD35 , LR3D01 to LR3D35, and LRD313 to LRD365.
      LA7D305 is for use on all other relays (except LRD01 to LRD35 and LR3D01 to LR3D35).

       

      Will the LAD7B10 or the LAD7B106 work on the Pre-Tesys D line LR2D15*** overload relays?

      Issue:
      Separate mount block needed for older style overload relay

      Product Line:
      IEC contactors and starters

      Environment:
      North American Products

      Resolution:
      No. These are a different design and will not work with the pre - Tesys overload relays.


       

      Will the LA7D1064 fit the new TeSys LRD overload relays?

      Issue:
      Identifying separate mount for newer style LRD overload relays

      Product Line:
      IEC contactors and starters

      Environment:
      Products sold and used in the United States

      Resolution:
      No, they are a different design and will not work with the Tesys overload relays, you will need the LAD7B10 or LAD7B10..

      What is the Difference between LADN206 and LADN20?

      LADN206 has 2N/O Lugs ring terminal
      LADN20 has 2 N/O - screw-clamps terminals
      Rest of the specifications are the same.

      what is new alternative for Code 15961 ?

      Code = A9C20833

      What size cable does a LAD7B10 accept?

      Issue:
      Need to know the size cable accepted by the LAD7B10 block.

      Product Line:
      IEC Contactors and starters

      Environment:
      Products sold and used in the United States

      Cause:
      Identifying cabling requirements.

      Resolution:
      It takes either a 1 flexible cable without cable end size 14-8 AWG or 1 flex cable with cable end size 16-12AWG or 1 solid cable without cable end size 16-10 AWG.


       

      Is the Clipsal 224/2 floor outlet still available

       Obsolete and deleted. Use a SBIP2P-XX  
      The PDL 535F has been obsoleted as well

      What is the temperature range for the ZB5AD range? ZB5AD2 ZB5AD3 ZB5AD4 ZB5AD5 ZB5AD7 ZB5AD8

      Ambient air temperature for storage -40...158 °F (-40 to 70 °C)
      Ambient air temperature for operation -13...158 °F (-25 to 70 °C)

      ETSNZ - How do I wire the BMXDDO3202K discrete IO 24 VDC positive logic module for a M340 PLC?

      BMXDDO3202K wiring the 24 VDC positive logic module as per the diagram:

      What can be done to fix the issue of HOA switch working backwards after ATV58 was replaced with ATV61 drive?

      Issue:
      After replacing the ATV58 with an ATV61 the HOA is working backwards.

      Product Line:
      EconoFlex 58

      Environment:
      All

      Cause:
      Reference analog input programming  need to be changed on the new ATV61 drive.

      Resolution:
      New ATV61 needs to be programmed.
      • Menu 1.6 Command menu
      • Ref 1 = AI2
      • Ref 1 B switching = LI3
      • Ref 1 B channel is AI1
      • Logic input LI3 is low for auto and high for hand.

      Why would the FFTK pass a Micrologic breaker on all functions except for Short-Time?

      Issue:
      Micrologic breaker fails short time test on FFTK

      Product Line:
      Circuit Breakers

      Environment:

      Powerpact P, R, Masterpact NT, NW

      Resolution:
      If the Inst. setting is too close to the short-time setting, the test kit may inject enough current to trip the breaker on Instantaneous.  Because an instantaneous trip is so fast the trip time will be wrong and the test kit will indicate that it failed.  Proper testing requires setting the Instantaneous function to at least 200% above the short-time.

      Is it possible to add side instantaneous auxiliary contacts blocks to the TeSys D DC coil contactors and relays?

      No, with the TeSYS D range, the DC coil contactors (both standard and low consumption) only allow front mountable auxiliaries.
      The part numbers LAD8N11, LAD8N20 and LAD8N02 will fit only the contactors with AC coils.

      What is the replacement AC coil for CAD32 and CAD50 relay?

      Issue:
      Are replacement  AC coil available for CAD32 and CAD50 relay?

      Product Line:
      Tesys Relays

      Environment:
      All Products

      Cause:
      Product selection

      Resolution:
      Volt = coil part number
      12 = LXD1J7
      21 = LXD1Z7
      24 = LXD1B7
      32 = LXD1C7
      36 = LXD1CC7
      42 = LXD1D7
      48 = LXD1E7
      60 = LXD1EE7
      100 = LXD1K7
      110 = LXD1F7
      115 = LXD1FE7
      120 = LXD1G7
      127 = LXD1FC7
      200 = LXD1L7
      208 = LXD1LL7
      220/230 = LXD1M7
      230 595 21 LXD1P7
      230/240 = LXD1U7
      277 781 30 LXD1W7
      380/400 = LXD1Q7
      400 = LXD1V7
      415 = LXD1N7
      440 = LXD1R7
      480 = LXD1T7
      600 = LXD1X7
      690 = LXD1Y7

       

      Input count range for the ADU205 Compact I/O module changes after converting from an A145 to a E275.

      Goals and Symptoms

      Why does the Input count range for the ADU205 Compact I/O module change after converting from
      a Compact 984-A145 PLC to a Compact 984-E275 PLC.

      Facts and Changes

      The input count range for the ADU205 Compact IO module is defined as 2049-6143 for an input range of
      -20mA to +20mA. When the PLC type is changed to 984-E275, the input count range is changed and the
      module input irange s no longer valid for the application.

      Causes and Fixes

      According to the 'Modicon A120 Seris I/O Modules User Guide', this is a normal behavior for the module.
      The problem is due to the different input resolution used for the 984-E2xx Compact PLC.

      To resolve the problem:

      • Open the rack view
      • Click on the BADU205 module in the rack view.
      • Clcik on the button that is located next to the 'Card Config' textbox.



      1.) Selecti the option for 13-bits resolution with the channel configured as -20mA/+20mA. This will provide an
      equivalent input count range with that obtained from the Compact A145 PLC..

      Legacy KB System (APS) Data: RESL176648 V1.0, Originally authored by on , Last Edited by on
      Related ranges: ProWORX