Specifications

hide show
Range
TeSys
Product or component type
electrical remote stop
Device short name
LAD
Accessory / separate part category
electrical accessory
Product compatibility
  • LRD313...LRD365
  • LRD01...35
  • LR3D01...D35
  • LR3D313...LR3D365
    • [Uc] control circuit voltage
      415/440 V AC 50/60 Hz
      Maximum inrush power in VA
      100 VA
      Net weight
      0.09 kg
      Compatibility code
      LAD
      Sustainable offer status
      Green Premium product
      REACh Regulation
      Free of Substances of Very High Concern above the threshold
      EU RoHS Directive
      Compliant
      Mercury free
      Yes
      RoHS exemption information
      Yes
      China RoHS Regulation
      Product out of China RoHS scope. Substance declaration for your information
      Environmental Disclosure
      ENVPEP111213EN_V1
      Circularity Profile
      N/A
      WEEE
      The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
      California proposition 65
      WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.gov
      Warranty
      18 months

      Documents & downloads

      hide show
      Filter items
      • All

      • CAD Files and Packs

      • Product Brochures

      • Movies

      • Technical Data Catalogues

      • Catalog Page

      • Technical Leaflet

      • Installation Instruction

      • Product Environmental

      • End of Life Manual

      • Data Bulletin

      • Operating Manuals

      • Certificates (MSDS)

      • Marine Certificate

      • White Paper

      • Declaration of Conformity

      Frequently Asked Questions

      hide show

      Does the LAD703 side or top mount to the overload

       It is side mount

      What is the part number for remote module for LR97D07?

      We can use
      LAD703 .

      What is the replacement AC coil for CAD32 and CAD50 relay?

      Issue:
      Are replacement  AC coil available for CAD32 and CAD50 relay?

      Product Line:
      Tesys Relays

      Environment:
      All Products

      Cause:
      Product selection

      Resolution:
      Volt = coil part number
      12 = LXD1J7
      21 = LXD1Z7
      24 = LXD1B7
      32 = LXD1C7
      36 = LXD1CC7
      42 = LXD1D7
      48 = LXD1E7
      60 = LXD1EE7
      100 = LXD1K7
      110 = LXD1F7
      115 = LXD1FE7
      120 = LXD1G7
      127 = LXD1FC7
      200 = LXD1L7
      208 = LXD1LL7
      220/230 = LXD1M7
      230 595 21 LXD1P7
      230/240 = LXD1U7
      277 781 30 LXD1W7
      380/400 = LXD1Q7
      400 = LXD1V7
      415 = LXD1N7
      440 = LXD1R7
      480 = LXD1T7
      600 = LXD1X7
      690 = LXD1Y7

       

      What is the difference between LAD703 and LA7D03

      Issue:
      Identifying differences between two similar part numbers

      Product Line:
      IEC contactors and starters

      Environment:
      Products sold and used in the United States

      Cause:
      Identifying differences between two similar part numbers

      Resolution:
      Both will remotely stop (trip) or electrically reset the overload, however;
      LAD703 is used on Tesys overload LRD01 through LRD35 and LR3D01 to LR3D35.
      LA7D03 is used on all other LR*D overload relays other than LRD01 to LRD35 and LR3D01 to LR3D35.


       

      Is there a retrofit plate available for replacement of LC1D40-D65 contactors with the LC1D40A-65A contactors?

      Use a LAD7X3 retrofit plate.


      CTA-ID : 2053453

      In regards to LAD5C11 LAD5C31 LAD5C12 LAD5C32 What is the maximum kW range that TeSys SoLink can be used with motor starter combination?

      TeSys SoLink is the connection module to connect GV2/GV3 motor circuit breakers to associated contactors and can be used with GV2 / GV3 breakers up to 30kW.
      For more information please visit the Link provided
      https://www.schneider-electric.com.au/australia/en/products-services/offer-updates/news-viewer.page?c_filepath=/templatedata/Content/News/data/en/local/automation_control/general_information/2014/10/20141024_tesys_solink_integration_system.xml

      In regards to LAD5C11 LAD5C31 LAD5C12 LAD5C32 SoLink What is the maximum number of motor starters that can be connected and controlled with each logic controller?

      Each TM3 I/O module is able to monitor and control up to 4 motor starters and up to 56 motor starters can be connected to logic controller.
      For more information aboput this range please Visit the Schneider website on the link provided
      https://www.schneider-electric.com.au/australia/en/products-services/offer-updates/news-viewer.page?c_filepath=/templatedata/Content/News/data/en/local/automation_control/general_information/2014/10/20141024_tesys_solink_integration_system.xml

      In regards to LAD5C11 LAD5C31 LAD5C12 LAD5C32 SoLink , Can TeSys SoLink be used with AC control supply?

      TeSys SoLink is suitable for 24VDC control supply; the TM3 I/O module provides the 24V DC control voltage to the motor starter.
      For more information on this range please visit the Schneider electric web site on the link provided
      https://www.schneider-electric.com.au/australia/en/products-services/offer-updates/news-viewer.page?c_filepath=/templatedata/Content/News/data/en/local/automation_control/general_information/2014/10/20141024_tesys_solink_integration_system.xml

      ETSNZ - Can Tesys F range contactors be used in safety applications?

      According to IEC60947-4-1 appendix F, mirror contact is one of the means necessary to ensure safety for contactors
      (in the standard "...mirror contact should not be relied upon exclusively as a means to ensure safety..." ).

      TeSys F contactors do not include internal mirror contacts. So we, Schneider, do not actively promote TeSys F as a contactor for safety applications.
      However, TeSys F can be fitted with auxiliary contacts add-on blocks. For some of these blocks LADN01, LADN02, LADN04, LADN11, LADN22, LADN31 and LADN13, a NC auxiliary contact has been recognised by VDE as mirror contact. This allows to use TeSys F in safety applications.
      Attached are the VDE Certificates recognising the NC auxiliary contact with the blocks mentioned above as mirror contact.

      To sum up and give clear answers to TeSys F and safety applications ;
      1. If Tesys F contactor can be used for safety applications?

      Yes, it can be used if, this is mandatory, it is fitted with one the above mentioned add-on blocks. VDE Certificate recognising the auxiliary contact as mirror can be provided.


      2. When asked, can we answer that Tesys F have mirror contact, provided by auxiliary contact blocks?

      Yes for the above mentioned add-on blocks and with the VDE Certificate

      Can I use a LA9D6569 reversing kit with LC1D40AU7 contactors

      No, correct kit is a LAD9R3.

      What is the difference between the LA7D305 and LAD7305, remote control reset mechanism by flexible cable?

      Issue:
      Identifying differences between two similar part numbers.

      Product Line:
      IEC contactors and starters

      Environment:
      Products sold and used in the United States

      Cause:
      Choosing the correct part number

      Resolution:
      LAD7305 is for use on LRD01 to LRD35 , LR3D01 to LR3D35, and LRD313 to LRD365.
      LA7D305 is for use on all other relays (except LRD01 to LRD35 and LR3D01 to LR3D35).

       

      Need the spare part code for a DOL starter LE1D12, only need the arm behind push button

       The part code is LAD9091

      Is the LAD7B10 a UL and CSA Recognized Component?

      Issue:
      Is the LAD7B10 a UL or CSA recognized component?

      Product Line:
      IEC Overload Mounting Kit

      Environment:
      IEC Contactors

      Cause:
      Clarify CSA and UL listing for IEC components

      Resolution:
      As of 6/30/2016 this device has been UL component recongnized. This device has not been CSA recognized

      Key words LAD7B10, UL, CSA, separate mounting

      Case Subject:
      LAD7B10

      What is the 415v remote reset for the LRD14 overload?

      The part number for the415VAC or DC remote reset for the LRD01...35 and the LRD313....365 is LAD703N
      See data sheet for more information......https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=LAD703N...User-added image
       

      What size cable does a LAD7B10 accept?

      Issue:
      Need to know the size cable accepted by the LAD7B10 block.

      Product Line:
      IEC Contactors and starters

      Environment:
      Products sold and used in the United States

      Cause:
      Identifying cabling requirements.

      Resolution:
      It takes either a 1 flexible cable without cable end size 14-8 AWG or 1 flex cable with cable end size 16-12AWG or 1 solid cable without cable end size 16-10 AWG.


       

      Will a single circuit auxiliary contact block, like a LADN10 or LADN01, fit onto the Tesys D09-D38 amp contactors?

      Issue:
      Identifying auxiliary contact blocks for Tesys D contactors

      Product Line:
      IEC contactors and starters

      Environment:
      Products sold and used in the United States

      Cause:
      single auxiliary contact block needed for use on a Tesys D line contactor

      Resolution:
      No, the single pole contact block will not fit . A LADN11,LADN20, LADN02 etc will fit. Anything with 2 auxiliary contacts in one block will fit.
       

      ATS48 C41Q Quelle est la reference de la peinture utilisee pour le caisson Gris RAL ???

      Goals and Symptoms

      ATS48 C41Q Quelle est la référence de la peinture utilisée pour le caisson
      Gris RAL ???

      Causes and Fixes

      Il s'agit de peinture RAL7030

      What are the part numbers for the ATS22 Protection Shrouds for the Power Terminals?

      Issue:
      What are the part numbers for the ATS22 Protection Shrouds for the Power Terminals?

      Product Line:
      ATS22 Altistart 22

      Environment:
      All

      Cause:
      Need replacement parts

      Resolution:
      Set of 6 power terminal protection shrouds
      ATS22C11S6,S6U ..C17S6,S6U      LA9F702
      ATS22C21S6,S6U ..C59S6,S6U      LA9F703

      What terminal protection shrouds fit the LR9F7*75, LR9F7*79, and LR9F7*81 overload relays?

      Issue:
      What terminal protection shrouds fit the LR9F7*75, LR9F7*79, and LR9F7*81 overload relays?

      Product Line:
      TeSys F-Line Contactors

      Environment:
      All Product Lines

      Cause:
      Can not find it in the Digest

      Resolution:
      The LA9F703 protection shrouds fit the LR9F7*75, LR9F7*79, and LR9F7*81 overload relays

      Will the LAD7B10 or the LAD7B106 work on the Pre-Tesys D line LR2D15*** overload relays?

      Issue:
      Separate mount block needed for older style overload relay

      Product Line:
      IEC contactors and starters

      Environment:
      North American Products

      Resolution:
      No. These are a different design and will not work with the pre - Tesys overload relays.


       

      Will the LA7D1064 fit the new TeSys LRD overload relays?

      Issue:
      Identifying separate mount for newer style LRD overload relays

      Product Line:
      IEC contactors and starters

      Environment:
      Products sold and used in the United States

      Resolution:
      No, they are a different design and will not work with the Tesys overload relays, you will need the LAD7B10 or LAD7B10..

      What the DC current contact ratings for the CAD50, CAD32, CAD503, CAD323, CAD506, and CAD326 relay?

      Issue:
      Checking on the DC current contact ratings for the CAD50, CAD32, CAD503,  CAD323,  CAD506, and  CAD326 relay.

      Product Line:
      CAD Industrial Relays

      Environment:
      Relays and Timers

      Resolution:
      Inductive:
      125V DC - 0.55 Amps make and break, 2.5 Amps cont.
      250V DC - 0.27 Amps make and break, 2.5 amps cont.
      600V DC - 0.10 Amps make and break, 2.5 Amps cont.

       

      What's the difference between ATS22..S6U and ATS22...S6 Softstart models?

      Issue:
      What's the difference between an ATS22..S6U and  ATS22..S6 soft start models?

      Product Line:
      Altistart 22 ATS22

      Environment:
      All models, All series

      Cause: 
      Altistart has difference voltage suffix S6U and S6.  

      Resolution:
      The ATS22..S6 model requires 220vac control power and has 24vdc logic inputs.





      The ATS22..S6U model requires 110vac control power and has 110vac logic inputs.