Latch Blk Lc1 D09-D65A 42V

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

  • TeSys D
  • TeSys D control relay
    • Range

      TeSys

      Product or component type

      mechanical latch block

      Product compatibility

    • LC1D09...D38
    • LC1DT20...DT40
    • TeSys D control relays
    • LC1D40A...D65A
    • LC1DT60A...DT80A
      • Sustainable offer status

        Green Premium product

        Warranty

        18 months

        Physical

        Mechanical durability

        500000 cycles

        Net weight

        0.07 kg

        Product certifications

      • UL
      • CSA
        • IP degree of protection

          IP2x conforming to VDE 0106

          Ambient air temperature for operation

          -25-55 °C

          Ambient air temperature for storage

          -40-80 °C

          REACh free of SVHC

          Yes

          EU RoHS Directive

          Compliant

          Toxic heavy metal free

          Yes

          Mercury free

          Yes

          RoHS exemption information

          Yes

          China RoHS Regulation

           Pro-active China RoHS declaration (out of China RoHS legal scope)

          Environmental Disclosure

          ENVPEP111213EN_V1

          Others

          [Uc] control circuit voltage

        • 24 V DC
        • 24 V AC 50/60 Hz
          • Mounting location

            front side

            Tripping control

          • manual
          • electrical
            • [Ui] rated insulation voltage

              690 V conforming to IEC 60947-5-1

              Power required in VA

              25 for AC circuit

              Power required in W

              30 W for DC circuit

              Maximum operating rate

              1200 cyc/h

              On-load factor

              10 %

              Protective treatment

              TH conforming to IEC 60068

              Unit Type of Package 1

              PCE

              Number of Units in Package 1

              1

              Package 1 Weight

              96 g

              Package 1 Height

              4.7 cm

              Package 1 width

              5.2 cm

              Package 1 Length

              6.5 cm

              Unit Type of Package 2

              S01

              Number of Units in Package 2

              32

              Package 2 Weight

              3.295 kg

              Package 2 Height

              15 cm

              Package 2 width

              15 cm

              Package 2 Length

              40 cm

              WEEE

              The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
              Show all specifications

              Documents & downloads

              hide show
              Filter items
              • All

              • Product Brochures

              • Technical Data Catalogues

              • Product Environmental

              • Installation Instruction

              Frequently Asked Questions

              hide show

              What is the replacement for a LA6DK10B

               Part code is LAD6K10B

              Is the LAD7B10 a UL and CSA Recognized Component?

              Issue:
              Is the LAD7B10 a UL or CSA recognized component?

              Product Line:
              IEC Overload Mounting Kit

              Environment:
              IEC Contactors

              Cause:
              Clarify CSA and UL listing for IEC components

              Resolution:
              As of 6/30/2016 this device has been UL component recongnized. This device has not been CSA recognized

              Key words LAD7B10, UL, CSA, separate mounting

              Case Subject:
              LAD7B10

              What is the Din rail terminal block to suit the LRD12?

              The LAD7B106 fits the LRD01 to LRD35 range.
               

              Will the LAD7B10 or the LAD7B106 work on the Pre-Tesys D line LR2D15*** overload relays?

              Issue:
              Separate mount block needed for older style overload relay

              Product Line:
              IEC contactors and starters

              Environment:
              North American Products

              Resolution:
              No. These are a different design and will not work with the pre - Tesys overload relays.


               

              What is the replacement for the CA3DK22BD?

              Issue:
              What is the replacement for the CA3DK22BD?

              Product Line:
              Relays and Timers

              Environment:
              Obsolete Products

              Cause:
              Legacy Replacement

              Resolution:
              The CA3DK is Obsolete. To electrically replace it, use a CAD32BD & a LAD6K10B
               

              What size cable does a LAD7B10 accept?

              Issue:
              Need to know the size cable accepted by the LAD7B10 block.

              Product Line:
              IEC Contactors and starters

              Environment:
              Products sold and used in the United States

              Cause:
              Identifying cabling requirements.

              Resolution:
              It takes either a 1 flexible cable without cable end size 14-8 AWG or 1 flex cable with cable end size 16-12AWG or 1 solid cable without cable end size 16-10 AWG.


               

              Can the old D-line front mount attachments fit on the new CAD relays?

              Issue: 
              Can the old D-line attachments fit the new CAD relays
               
              Product Line:
              IEC Contactors

              Environment:
              Tesys D contactors and relays
               
              Cause:
              Using old accessories with new CAD relays

              Resolution:
               Yes, the old style front mount latch attachments, timing attachments, and auxiliary contacts will mount on the new Tesys D-line relays.

              Will the LA7D1064 fit the new TeSys LRD overload relays?

              Issue:
              Identifying separate mount for newer style LRD overload relays

              Product Line:
              IEC contactors and starters

              Environment:
              Products sold and used in the United States

              Resolution:
              No, they are a different design and will not work with the Tesys overload relays, you will need the LAD7B10 or LAD7B10..

              Will a single circuit auxiliary contact block, like a LADN10 or LADN01, fit onto the Tesys D09-D38 amp contactors?

              Issue:
              Identifying auxiliary contact blocks for Tesys D contactors

              Product Line:
              IEC contactors and starters

              Environment:
              Products sold and used in the United States

              Cause:
              single auxiliary contact block needed for use on a Tesys D line contactor

              Resolution:
              No, the single pole contact block will not fit . A LADN11,LADN20, LADN02 etc will fit. Anything with 2 auxiliary contacts in one block will fit.
               

              What is the replacement AC coil for CAD32 and CAD50 relay?

              Issue:
              AC coil replacement for CAD32 and CAD50

              Product Line:
              Relays

              Environment:
              Tesys CAD Control Relays

              Cause:
              Product selection

              Resolution:
              Volt = coil part number
              12 = LXD1J7
              21 = LXD1Z7
              24 = LXD1B7
              32 = LXD1C7
              36 = LXD1CC7
              42 = LXD1D7
              48 = LXD1E7
              60 = LXD1EE7
              100 = LXD1K7
              110 = LXD1F7
              115 = LXD1FE7
              120 = LXD1G7
              127 = LXD1FC7
              200 = LXD1L7
              208 = LXD1LL7
              220/230 = LXD1M7
              230 595 21 LXD1P7
              230/240 = LXD1U7
              277 781 30 LXD1W7
              380/400 = LXD1Q7
              400 = LXD1V7
              415 = LXD1N7
              440 = LXD1R7
              480 = LXD1T7
              600 = LXD1X7