D40A-D65A Varistor 24-48V Ac/Dc Suppres

D40A-D65A Varistor 24-48V Ac/Dc Suppres

D40A-D65A Varistor 24-48V Ac/Dc Suppres

Item Number: LAD4V3E

Retail
$60.50
RRP (Inc. GST)

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

TeSys D

Range

TeSys

Product or component type

suppressor module

Product compatibility

  • 3P LC1D40A...D80A
  • 4P LC1DT60A...DT80A
    • Sustainable offer status

      Green Premium product

      Warranty

      18 months

      Physical

      Mounting mode

      by clips

      Net weight

      0.02 kg

      Ambient air temperature for operation

      -25-55 °C

      Ambient air temperature for storage

      -40-80 °C

      REACh free of SVHC

      Yes

      EU RoHS Directive

      Compliant

      Toxic heavy metal free

      Yes

      Mercury free

      Yes

      RoHS exemption information

      Yes

      China RoHS Regulation

       Pro-active China RoHS declaration (out of China RoHS legal scope)

      Environmental Disclosure

      ENVPEP111253EN

      Others

      Device short name

      LAD4

      Mounting location

      front

      Suppressor technology

      varistor (peak limiting)

      [Uc] control circuit voltage

    • 24...48 V DC
    • 24...48 V AC 50/60 Hz
      • Maximum peak voltage

        2 Uc

        Compatibility code

        LAD4

        Unit Type of Package 1

        PCE

        Number of Units in Package 1

        1

        Package 1 Weight

        19 g

        Package 1 Height

        2 cm

        Package 1 width

        5 cm

        Package 1 Length

        7 cm

        Unit Type of Package 2

        BB1

        Number of Units in Package 2

        10

        Package 2 Weight

        192 g

        Package 2 Height

        6.2 cm

        Package 2 width

        7.5 cm

        Package 2 Length

        12 cm

        Unit Type of Package 3

        S01

        Number of Units in Package 3

        100

        Package 3 Weight

        2.118 kg

        Package 3 Height

        15 cm

        Package 3 width

        15 cm

        Package 3 Length

        40 cm

        WEEE

        The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
        Show all specifications

        Documents & downloads

        hide show
        Filter items
        • All

        • Product Brochures

        • Technical Data Catalogues

        • Product Environmental

        • Installation Instruction

        • Declaration of Conformity

        Frequently Asked Questions

        hide show

        Where can I find installation instructions for the LAD703 remote reset module?

        Issue:
        Installation and connection instructions for LAD703F

        Product line:
        Tesys D

        Environment:
        Remote reset module LAD703B LAD703F LAD703J LAD703E LAD703M LAD703Q LAD703N

        Cause:
        Documentation

        Resolution:
        See the attached instructions to mount the LAD703 onto the LRD style overloads.
        Apply wiring to the C1 and C2 terminals. 
        When the appropriate voltage is applied, the overload will reset.

        Are the LAD703F coils rated for continuous duty?

        Issue:
        Can you continuously press the reset button?

        Product line:
        Tesys D IEC Contactors and Overload Accessories

        Environment:
        LAD703 remote stop or electrical reset
        LA7D03 remote tripping or electrical reset

        Cause:
        Customer was using competitor brand and it burns after 10 seconds

        Resolution:
        The time for which the coil of the remote tripping or electrical resetting device, LAD703 or LA7D03 can remain energized depends on the rest time in between energizing the coil. 
        Minimum pulse to energize is 200ms

        1 second pulse needs a 9 second rest time
        5 second pulse needs a 30 second rest time
        10 second pulse needs a 90 second rest time
        Maximum duration of energizing the coil is 20 seconds and would require a 300 second rest time. 
         

        What is the part number for a varistor coil surge suppressor for a LC1D09 to LC1D32 3 pole and LC1DT20 to LC1DT40 4 pole?

        Issue:
        Surge suppressor part number is needed

        Product Line:
        TeSys D line Contactors

        Environment:
        Products sold and used in the United States

        Cause:
        Need a varistor coil surge suppressor in their application

        Resolution:
        For 24 to 48 volts AC LAD4VE, for 50 to 127 volts AC LAD4VG, and for 110 to 250 volts AC LAD4VU.
        These will limit the transient to 2 times nominal voltage and increases drop out time 1.1 to 1.5 times normal.

         

        What is the replacement AC coil for CAD32 and CAD50 relay?

        Issue:
        AC coil replacement for CAD32 and CAD50

        Product Line:
        Relays

        Environment:
        Tesys CAD Control Relays

        Cause:
        Product selection

        Resolution:
        Volt = coil part number
        12 = LXD1J7
        21 = LXD1Z7
        24 = LXD1B7
        32 = LXD1C7
        36 = LXD1CC7
        42 = LXD1D7
        48 = LXD1E7
        60 = LXD1EE7
        100 = LXD1K7
        110 = LXD1F7
        115 = LXD1FE7
        120 = LXD1G7
        127 = LXD1FC7
        200 = LXD1L7
        208 = LXD1LL7
        220/230 = LXD1M7
        230 595 21 LXD1P7
        230/240 = LXD1U7
        277 781 30 LXD1W7
        380/400 = LXD1Q7
        400 = LXD1V7
        415 = LXD1N7
        440 = LXD1R7
        480 = LXD1T7
        600 = LXD1X7
        690 = LXD1Y7

         

        In regards to LAD5C11 LAD5C31 LAD5C12 LAD5C32 What is the maximum kW range that TeSys SoLink can be used with motor starter combination?

        TeSys SoLink is the connection module to connect GV2/GV3 motor circuit breakers to associated contactors and can be used with GV2 / GV3 breakers up to 30kW.
        For more information please visit the Link provided
        https://www.schneider-electric.com.au/australia/en/products-services/offer-updates/news-viewer.page?c_filepath=/templatedata/Content/News/data/en/local/automation_control/general_information/2014/10/20141024_tesys_solink_integration_system.xml

        In regards to LAD5C11 LAD5C31 LAD5C12 LAD5C32 SoLink What is the maximum number of motor starters that can be connected and controlled with each logic controller?

        Each TM3 I/O module is able to monitor and control up to 4 motor starters and up to 56 motor starters can be connected to logic controller.
        For more information aboput this range please Visit the Schneider website on the link provided
        https://www.schneider-electric.com.au/australia/en/products-services/offer-updates/news-viewer.page?c_filepath=/templatedata/Content/News/data/en/local/automation_control/general_information/2014/10/20141024_tesys_solink_integration_system.xml

        In regards to LAD5C11 LAD5C31 LAD5C12 LAD5C32 SoLink , Can TeSys SoLink be used with AC control supply?

        TeSys SoLink is suitable for 24VDC control supply; the TM3 I/O module provides the 24V DC control voltage to the motor starter.
        For more information on this range please visit the Schneider electric web site on the link provided
        https://www.schneider-electric.com.au/australia/en/products-services/offer-updates/news-viewer.page?c_filepath=/templatedata/Content/News/data/en/local/automation_control/general_information/2014/10/20141024_tesys_solink_integration_system.xml

        Will a LAD4RCE or LA4DRCU also fit a LC2D09 thru LC2D38 reversing contactors?

        Issue:
        Identifying accessories for reversing contactors

        Product Line:
        IEC contactors and starters

        Environment:
        Products sold and used in the United States

        Cause:
        Accessories used on non-reversing contactors are also needed for reversing application

        Resolution:
        Yes, the LC2D contactors are provided standard with one on the left contactor. One may be added to the right contactor.


        CTA-ID : 2022733

        Can I use a LA9D6569 reversing kit with LC1D40AU7 contactors

        No, correct kit is a LAD9R3.

        What suppressor do I need for a LC1DT40 contactor 110Vac

        You need to use a LAD4RCU - RC circuit suppressor 110-240Vac.

        Are the LAD4 RC suppressors CE marked?

        Product Line:  
        Tesys D line Contactors and Accessories

        Resolution:
        Yes these are CE marked.
         

        What do the LA4D timing modules require for mounting on LC1D40A through LC1D65A contactors?

        Product Line:
         
        Tesys D line Contactors and Accessories

        Resolution:
         
        Mounting this module to TeSys LC1D40A through LC1D65A contactor requires the use of the LAD4BB3 wiring adaptor. This adaptor can be fitted only to contactors with no coil suppressor.
         
        Show More