Quantcast

Star Delta Kit for Lc1D80

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

TeSys D

Range

TeSys

Product or component type

kit for star-delta

Product compatibility

LC1D80

Sustainable offer status

Green Premium product

Warranty

18 months

Physical

Range compatibility

TeSys D

Net weight

0.68 kg

REACh Regulation

Free of Substances of Very High Concern above the threshold

REACh free of SVHC

Yes

EU RoHS Directive

Compliant

Toxic heavy metal free

Yes

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

 Pro-active China RoHS declaration (out of China RoHS legal scope)

Environmental Disclosure

ENVPEP110807EN_V1

Others

Product name

TeSys D

Device short name

LA9D

Poles description

3P

Kit composition

  • set of power connection
  • time delay contact block LAD S2
  • screws and clamps for fixing contactors to the plate
    • Compatibility code

      LA9D

      Unit Type of Package 1

      PCE

      Number of Units in Package 1

      1

      Package 1 Weight

      616 g

      Package 1 Height

      6 cm

      Package 1 width

      14 cm

      Package 1 Length

      17.5 cm

      Unit Type of Package 2

      S03

      Number of Units in Package 2

      20

      Package 2 Weight

      12.864 kg

      Package 2 Height

      30 cm

      Package 2 width

      30 cm

      Package 2 Length

      40 cm

      WEEE

      The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
      Show all specifications

      Documents & downloads

      hide show
      Filter items
      • All

      • Product Brochures

      • Technical Data Catalogues

      • Product Environmental

      • Installation Instruction

      Frequently Asked Questions

      hide show

      Will the LAD** time delay auxiliary contact module fit the D2 series pre-Tesys contactors?

      Issue:
      Can new accessories be used on older style contactors

      Product Line:
      IEC contactors and starters

      Environment:
      Pre-Tesys Contactors

      Cause:
      Identifying product compatibility

      Resolution:
      Yes, all front mount D2 and Tesys series auxiliary modules are backward forward compatible.

      Will a single circuit auxiliary contact block, like a LADN10 or LADN01, fit onto the Tesys D09-D38 amp contactors?

      Issue:
      Identifying auxiliary contact blocks for Tesys D contactors

      Product Line:
      IEC contactors and starters

      Environment:
      Tesys D Auxiliary contact blocks

      Cause:
      single auxiliary contact block needed for use on a Tesys D line contactor

      Resolution:
      No, the single pole contact block will not fit . A LADN11,LADN20, LADN02 etc will fit. Anything with 2 auxiliary contacts in one block will fit.

      What is the difference between the pre-Tesys and Tesys D line contactors?

      Issue:
      What is the difference between the pre-Tesys and Tesys D line contactors?

      Product Line:
      IEC Telemecanique contactors

      Environment:
      Tesys D line contactors

      Cause:
      The pre-tesys D line contactors have been replaced by the new Tesys D line contactors
       
      Resolution:

       

      The pre-Tesys style of contactor included the auxiliary contact arrangement in the part number, for example the LC1D0911 is a 9 amp contactor with 1 normally open and one normally closed auxiliary contact, and the LC1D8010 is an 80 amp contactor with 1 normally open auxiliary contact and no normally closed auxiliary contacts. The current line of contactors do not include the auxiliary contacts in the part number, but automatically come with 1 normally open and 1 normally closed auxiliary contact; both the LC1D09 and LC1D80 would come with one of each.  

      Can the single pole LA1DN and LADN auxiliary contact module be mounted on the TeSys contactors?

      ISSUE
      In which contactors can the LA1DN and LADN auxiliary contacts be mounted?

      PRODUCT LINE
      Auxiliary contacts for the Tesys D line

      ENVIRONMENT
      Tesys D-Line and Tesys F

      RESOLUTION
      These contacts will only fit on the following contactors:
      Front mount only for LC1D40 through LC1D115 devices and LC1D40A - LC1D65A.
      Left side mount only to LC1F contactors