Specifications

hide show
Range of product
TeSys D
Range
  • TeSys
  • Linergy
    • Device short name
      LA9D
      Product or component type
      set of connections
      Poles description
      3P
      Electrical circuit type
      reversing contactor
      Range compatibility
      TeSys D
      Product compatibility
    • LC1D40A
    • LC1D50A
    • LC1D65A
    • LC1D80A
      • Net weight
        0.13 kg
        Compatibility code
        LA9D
        REACh Regulation
        Free of Substances of Very High Concern above the threshold
        REACh free of SVHC
        Yes
        EU RoHS Directive
        Compliant
        Toxic heavy metal free
        Yes
        Mercury free
        Yes
        RoHS exemption information
        Yes
        China RoHS Regulation
         Pro-active China RoHS declaration (out of China RoHS legal scope)
        WEEE
        The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
        Warranty
        18 months

        Documents & downloads

        hide show
        Filter items
        • All

        • Product Brochures

        • Technical Data Catalogues

        • End of Life Manual

        • Product Environmental

        • Installation Instruction

        Frequently Asked Questions

        hide show

        Can I use a LA9D6569 reversing kit with LC1D40AU7 contactors

        No, correct kit is a LAD9R3.

        What is the difference between LA9D11569 and LA9D115691?

        Issue:
        Identifying differences between two part numbers

        Product Line:
        IEC contactors and starters

        Environment:
        Products sold and used in the United States

        Cause:
        Selecting between two similar part numbers

        Resolution:
        LA9D11569 is a set of power connections. LA9D115691 is the bottom connector only as shown on page 16-9 of Digest 173 for the LC1D115 and LC1D150 contactor.


         

        Is the LR9D5369 overload still available

         Yes it is

        What is needed to interlock two LC1D80 or two LC1D95 contactors for a reversing application?

        Issue:
        Mechanical and electrical interlock for LC1D80** and LC1D95**

        Product Line:
        Tesys D line Contactors

        Environment:
        Contactor Accessories

        Resolution:
        For LC1D80 or LC1D95 with AC coils
        LA9D4002 mechanical interlock with integral electrical interlocking
        LA9D50978 mechanical interlock without electrical interlocking
        LA9D8069 - 3 pole power connectors***

        For LC1D80 or LC1D95 with DC coils
        LA9D8002 mechanical interlock with integral electrical interlocking
        LA9D80978 mechanical interlock without electrical interlocking
        LA9D8069 - 3 pole power connectors***

        ***Connectors for 4 pole contactor set is LA9D8070.

        Do the Everlink reversing contactors come with electrical interlocking?

        Issue:
        Looking for electrical interlock kit for the LC1D65A Everlnk contactors

        Product line:
        Tesys D LC1D40A, LC1D50A, LC1D65A

        Environment:
        Everlink, all voltage codes

        Cause:
        Old D2 version offered an electrical interlock kit

        Resolution:
        The current Everlink version does not offer an electrical interlock kit.  The customer can wire electrical interlocking using the normally closed contacts provided on the contactor.

        Does LC1D65AB7 3P (3 NO) TeSys Model D contactor have a normally opened and normally closed auxiliary contact?

        What is the overload for LC1D65AU7 Contactor, when rating is 20-25A ?

        17-25 Amps = LRD325
        23-32 Amps =LRD332

        What is the part number for 60A contactor with 240V/415V coil?

        What is the difference between a LC1D65A3U7 and LC1D65AU7?

        The difference between the LC1D65A3U7 and the LC1D65AU7 is that the Control connections are spring terminals for the LC1D65A3U7 and screw clamp terminals for the LC1D65AU7
        see data sheets for comparrisons...
        https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=lc1d65a3u7

        https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=lc1d65au7
        User-added image.................User-added image

        Can the LE1D and LE2D enclosed Tesys D-Line contactors be obtained with DC control coils?

        Issue:  
        Tesys D enclosed starter with a DC control 

        Product Line:
         Enclosed Tesys D line starters

        Environment:
        North American Products
         
        Cause:
        DC control circuit 
         
        Resolution:
        Yes but limited to 24 VDC.