Set of 6 Shrouds

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

TeSys D

Range

TeSys

Product or component type

protective cover for connector

Product compatibility

  • LC1D150
  • LC1D115
    • Warranty

      18 months

      Physical

      Net weight

      0.25 kg

      REACh free of SVHC

      Yes

      EU RoHS Directive

      Compliant

      Toxic heavy metal free

      Yes

      Mercury free

      Yes

      RoHS exemption information

      Yes

      China RoHS Regulation

       Pro-active China RoHS declaration (out of China RoHS legal scope)

      Others

      Device short name

      LA9D

      Accessory / separate part category

      installation accessory

      Poles description

      3P

      Compatibility code

      LA9D

      Unit Type of Package 1

      PCE

      Number of Units in Package 1

      1

      Package 1 Weight

      260 g

      Package 1 Height

      7 cm

      Package 1 width

      8.2 cm

      Package 1 Length

      15.8 cm

      Unit Type of Package 2

      S03

      Number of Units in Package 2

      21

      Package 2 Weight

      5.94 kg

      Package 2 Height

      30 cm

      Package 2 width

      30 cm

      Package 2 Length

      40 cm

      WEEE

      The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
      Show all specifications

      Documents & downloads

      hide show
      Filter items
      • All

      • Product Brochures

      • Technical Data Catalogues

      • Installation Instruction

      Frequently Asked Questions

      hide show

      What is the part code for terminal shrouds to fit LC1D115 or LC1D150

      The part code is LA9D115703 for 3 pole
      The part code for 4 pole is LA9D115704

      What is the difference between LA9D11569 and LA9D115691?

      Issue:
      Identifying differences between two part numbers

      Product Line:
      IEC contactors and starters

      Environment:
      Products sold and used in the United States

      Cause:
      Selecting between two similar part numbers

      Resolution:
      LA9D11569 is a set of power connections. LA9D115691 is the bottom connector only as shown on page 16-9 of Digest 173 for the LC1D115 and LC1D150 contactor.


       

      What code is a mechanical interlock for the 4pole LC1D1150046 contactor?

      LA9D11502 will fit the 4p LC1D115 and LC1D150 contactors

      Are replacement contacts available for LC1D115?

      Issue:
      Replacement contacts needed for 115 amp D line contactor

      Product Line:
      IEC contactors and starters

      Environment:
      Products sold and used in the United States

      Cause:
      Identifying part number to order replacement contact kit

      Resolution:
      Yes, order LA5D1158031 for 3 pole kit or LA5D115804 for 4 pole kit.


      CTA-ID : 11125

      What is the terminal shroud part number for a LC1D1156**

      The part code is LA9D115703

      What is the mechanical interlock for the LC1D115 contactor?

      Issue:
      Interlock needed for a pair of LC1D115 contactors

      Product Line:
      NEMA combination starters

      Environment:
      Products sold and used in the United States

      Cause:
      Application requires mechanical interlocking

      Resolution:
      LA9D11502. It includes the electrical interlocks.

       

      What is part number for terminal shrouds for LC1D1506U7?

      The part number for terminal shrouds for LC1D1506 and LC1D1156 contactors is LA9D115703
      User-added image

      LA9D115703

      Shrouds - for 3 poles TeSys model D

      For furher information see:
      https://www.schneider-electric.com.au/en/product/LA9D115703/shrouds---for-3-poles-tesys-model-d

       

      Are the D-Line contactors rated to break DC voltages?

      Issue: 
      Can the TeSys D line be used to control DC loads? 

      Product Line:
      Tesys D contactors

      Environment:
      Products sold and used in the United States
       
      Cause:
       DC power circuit
       
      Resolution:
       
      Yes, 75 VDC (125 VDC for D115 & D150) per pole which means that through a four pole device breaking 300 VDC is possible by wiring all four power poles in series. However, be aware that the device current ratings will differ according to the number of poles in series and the type of application.

      Devices are suitable but not UL Listed for DC applications.

      More information on their DC ratings can be found in the current TeSys Motor Control and Protection Compentns catalog: https://www.schneider-electric.us/en/download/document/MKTED210011EN/


       

      What are the coil voltage codes for the LC1D115 / LC2D115 and LC1D150 / LC2D150 TeSys contactor?

      Issue:
      LC1D115 / LC2D115 and LC1D150 / LC2D150

      Product Line:
      Tesys D line Contactors

      Environment:
      North America

      Resolution:
      The following list the more common voltage suffix codes for these product lines.  For a more comprehensive list and to determine compatibility with a given product, refer to the catalog below.

      Note 1: LC1D150 contactors are only available with *7 coil codes.
      Note 2: Coil Code ending number represents frequency rating as follows:
      5 = 50 Hertz
      6 = 60 Hertz
      7 = 50/60 Hertz

      AC Volts ___Code                DC Volts ___Code
      24 ___ B5 or B6 or B7          12 ___ Not Avail.        
      42 ___ D5 or D7                   24 ___ BD
      48 ___ E5 or E6 or E7          36 ___ CD
      110 ___ F5 or F6 or F7         48 ___ ED
      115 ___ FE5 or FE7             60 ___ ND
      120 ___ G6 or G7                72 ___ SD
      127 ___ FC5 or FC7            110 ___ FD
      208 ___ L6 or LE7               125 ___ GD
      220 ___ M5 or M6 or M7       220 ___ MD
      230 ___ P5 or P7                 250 ___ UD
      240 ___ U5 or U6 or U7        440 ___ RD
      277 ___ W6 or UE7                
      380 ___ Q5 or Q6 or Q7                
      400 ___ V5 or V7                
      415 ___ N5 or N7                
      440 ___ R5 or R6 or R7                
      480 ___ T6 or T7                
      500 ___ S5 or S7                


       

      Is 240 volt replacement control coil available for LC1D11500?

      Issue:
      Identifying replacement coil part number

      Product Line:
      IEC contactors and starters

      Environment:
      Products sold and used in the United States

      Cause:
      Replacement control coil needed for older style Tesys Contactor

      Resolution:
      Yes, order LX1D8U5 for 50 hertz, LX1D8U6 for 60 hertz or LX1D8U7 for 50/60 hertz. Average coil consumption is 300 VA inrush 22 VA sealed for 50 hertz, 300 VA inrush 22 VA sealed for 60 hertz and 280 to 350 VA inrush 2 to 18 VA sealed for 50/60 hertz.


      CTA-ID : 11321

      What is the part number for Side mount auxiliary 2NC and terminal shroud for LC1D1506 contactor?

      The part number for Side mount auxiliary 2NC and terminal shroud for LC1D1506 contactor are LAD8N02 and LA9D115703.
      LAD8N02                                                                                                                                    LA9D115703
       TeSys D - auxiliary contact block - 2 NC - screw clamp terminals                              shrouds - for 3 poles TeSys model D

      For more information see:

      https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=LAD8N02
      https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=LA9D115703

                                                                                                                                                                                                                                                                                                                                                                                                             

                                                  

      Will the LAD** time delay auxiliary contact module fit the D2 series pre-Tesys contactors?

      Issue:
      Can new accessories be used on older style contactors

      Product Line:
      IEC contactors and starters

      Environment:
      Products sold and used in the United States

      Cause:
      Identifying product compatibility

      Resolution:
      Yes, all front mount D2 and Tesys series auxiliary modules are backward forward compatible.


       
      Show More