Quantcast

Terminal Block

Product Dimensions

Width icon

Width75 mm

Height icon

Height104 mm

Depth icon

Depth121 mm

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range

TeSys

Product or component type

terminal block

Product compatibility

  • LR2D35..
  • LR3D35..
  • LR3D33..
  • LRD33..
    • Sustainable offer status

      Green Premium product

      Warranty

      18 months

      Physical

      Quantity per set

      set of 1

      Connections - terminals

      screw terminals

      Height

      104 mm

      Width

      75 mm

      Depth

      121 mm

      Net weight

      0.37 kg

      REACh Regulation

      Free of Substances of Very High Concern above the threshold

      REACh free of SVHC

      Yes

      EU RoHS Directive

      Compliant

      Toxic heavy metal free

      Yes

      Mercury free

      Yes

      RoHS exemption information

      Yes

      China RoHS Regulation

       Pro-active China RoHS declaration (out of China RoHS legal scope)

      Environmental Disclosure

      ENVPEP110101EN

      Circularity Profile

      ENVEOLI1101001EN

      California proposition 65

      WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov

      Others

      Number of Units in Package 1

      1

      Number of Units in Package 2

      33

      Number of Units in Package 3

      132

      Package 1 width

      10.5 cm

      Package 2 Height

      30 cm

      Package 2 Length

      60 cm

      Package 2 width

      40 cm

      Package 3 Height

      80 cm

      Package 3 Length

      60 cm

      Package 1 Height

      9.5 cm

      Package 1 Length

      13.5 cm

      Package 3 width

      80 cm

      Unit Type of Package 1

      PCE

      Unit Type of Package 2

      S04

      Unit Type of Package 3

      P06

      Device short name

      LA7D

      Accessory / separate part category

      connection accessory

      Compatibility code

      LA7D

      Package 1 Weight

      251 g

      Package 2 Weight

      9.148 kg

      Package 3 Weight

      50.195 kg

      WEEE

      The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
      Show all specifications

      Frequently Asked Questions

      hide show

      What D-line overload relays use the LA7D3064 separate mounting kit?

      Issue
      LA7D3064 with LC1D compatibility

      Product Line
      Overload relay

      Environment
      Tesys and Pre Tesys D-line

      Cause
      Fit, compatibility, and product features 

      Resolution
      The LRD3***   LR3D3***, LR2D35** D-line overload relays.

      How to use LRD01…35 LRD33•• & LRD43•• and LRD33** as an indepentent relay?

      The LRD relays has a solid tag to be used with LC1D** contactors. If you are not using LC1D contactors then using the following accessories you can terminate cable directly.

      For LRD01…35 use the following part: LAD7B106
      For LRD33•• & LRD43•• (3) use the following part: LA7D3064

      Will the LA7D1064 fit the new TeSys LRD overload relays?

      Issue:
      Identifying separate mount for newer style LRD overload relays

      Product Line:
      IEC contactors and starters

      Environment:
      Products sold and used in the United States

      Resolution:
      No, they are a different design and will not work with the Tesys overload relays, you will need the LAD7B10 or LAD7B10..

      Are the LAD703F coils rated for continuous duty?

      Issue:
      Continuous duty on a LAD703F.

      Product line:
      Tesys D IEC Contactors and Overload Accessories

      Environment:
      LAD703 remote stop or electrical reset
      LA7D03 remote tripping or electrical reset

      Cause:
      Customer was using competitor brand and it burns after 10 seconds

      Resolution:
      The time for which the coil of the remote tripping or electrical resetting device, LAD703 or LA7D03 can remain energized depends on the rest time in between energizing the coil. 
      Minimum pulse to energize is 200ms

      1 second pulse needs a 9 second rest time
      5 second pulse needs a 30 second rest time
      10 second pulse needs a 90 second rest time
      Maximum duration of energizing the coil is 20 seconds and would require a 300 second rest time. 
       

      What is the difference between the LA7D305 and LAD7305, remote control reset mechanism by flexible cable?

      Issue:
       LA7D305 and LAD7305 Difference

      Product Line:
      IEC contactors and starters

      Environment:
      LRD Accessories

      Cause:
      Choosing the correct part number

      Resolution:
      LAD7305 is for use on LRD01 to LRD35 , LR3D01 to LR3D35, and LRD313 to LRD365.
      LA7D305 is for use on all other relays (except LRD01 to LRD35 and LR3D01 to LR3D35).

      What is needed to interlock two LC1D80 or two LC1D95 contactors for a reversing application?

      Issue:
      Mechanical and electrical interlock for LC1D80** and LC1D95**

      Product Line:
      Tesys D line Contactors

      Environment:
      Contactor Accessories

      Resolution:
      For LC1D80 or LC1D95 with AC coils
      LA9D4002 mechanical interlock with integral electrical interlocking
      LA9D50978 mechanical interlock without electrical interlocking
      LA9D8069 - 3 pole power connectors***

      For LC1D80 or LC1D95 with DC coils
      LA9D8002 mechanical interlock with integral electrical interlocking
      LA9D80978 mechanical interlock without electrical interlocking
      LA9D8069 - 3 pole power connectors***

      ***Connectors for 4 pole contactor set is LA9D8070.
      Show More