Auxiliary contact block TeSys LA1SK

TeSys SK Auxiliary Contact Block, 1 NO + 1 NC

Catalogue Number: LA1SK11
Auxiliary contact block TeSys LA1SK
Retail
$94.24
RRP (Inc. GST)

Specifications

hide show
Range of product
  • TeSys SK
  • TeSys SK control relay
    • Range
      TeSys
      Device short name
      LA1SK
      Product or component type
      auxiliary contact block
      Product compatibility
      LC1SK
      Auxiliary contacts operation
      instantaneous
      Pole contact composition
      1 NO + 1 NC
      Connections - terminals
    • screw clamp terminals 1 cable(s) 1.5-6 mm²solid
    • screw clamp terminals 2 cable(s) 1.5-4 mm²solid
    • screw clamp terminals 1 cable(s) 0.5-6 mm²flexible with cable end
    • screw clamp terminals 2 cable(s) 0.35-2.5 mm²flexible with cable end
    • screw clamp terminals 1 cable(s) 0.35-6 mm²flexible without cable end
    • screw clamp terminals 2 cable(s) 0.35-1.5 mm²flexible without cable end
      • Mounting location
        front side
        [Ui] rated insulation voltage
      • 690 V conforming to IEC 60947
      • 690 V conforming to BS 5424
      • 690 V conforming to VDE 0110 group C
      • 690 V conforming to CSA C22.2 No 14
        • [Ue] rated operational voltage
          690 V AC <= 400 Hz
          [Ith] conventional free air thermal current
          10 A (at 55 °C)
          Associated fuse rating
        • 10 A gL conforming to IEC 60947
        • 10 A gL conforming to VDE 0660
          • Tightening torque
            0.8 N.m - on screw clamp terminals
            Width
            27 mm
            Net weight
            0.022 kg
            Compatibility code
            LA1SK
            Standards
          • VDE 0660
          • BS 5424
          • IEC 60947
          • NF C 63-110
            • Product certifications
            • CSA
            • UL
              • IP degree of protection
                IP2x
                Protective treatment
                TC conforming to IEC 60068
                Ambient air temperature for operation
                -20-50 °C
                Ambient air temperature for storage
                -50-70 °C
                Operating altitude
                2000 m without
                Sustainable offer status
                Green Premium product
                EU RoHS Directive
                Compliant
                Mercury free
                Yes
                RoHS exemption information
                Yes
                China RoHS Regulation
                Product out of China RoHS scope. Substance declaration for your information
                Environmental Disclosure
                ENVPEP111274EN
                WEEE
                The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                Warranty
                18 months

                Frequently Asked Questions

                hide show

                Why will LA1SK11 adder deck not fit on CA2SK11 relay?

                Issue:
                Why will LA1SK11 adder deck not fit on CA2SK11 relay?

                Product Line:
                Tesys Relays

                Environment:
                All Products

                Cause:
                Product Features

                Resolution:
                No, LA1SK11 mounts only on the CA2SK20 relay.




                CTA-ID : 2014524

                Can the old D-line front mount attachments fit on the new CAD relays?

                Issue: 
                Can the old D-line attachments fit the new CAD relays
                 
                Product Line:
                IEC Contactors

                Environment:
                Tesys D contactors and relays
                 
                Cause:
                Using old accessories with new CAD relays

                Resolution:
                 Yes, the old style front mount latch attachments, timing attachments, and auxiliary contacts will mount on the new Tesys D-line relays.

                What is the part number for the replacement coil for the CA2SK11 relays?

                Issue:
                Customer needs a replacement coil for the CA2SK11 relay.

                Product Line:
                TeSys SK IEC Style Relays              

                Environment:
                IEC Style Industrial Control Relays

                Cause:
                Clarify if customer can order new coil or replace entire relay

                Resolution:
                Coil is not a replaceable part.
                 

                Why does my other equiptment trip when my contactor releases?

                The colapsing coil voltage on DC is causing a Back EMF (electro magnetic field) issue. This is solved with either a varistor LA4SKE1E or a Diode LA4SKC1U on the LP1K09 contactor.

                For further information please visit https://www.clipsal.com/Trade
                 

                What is the pin configuration for the BALS211?

                The BALS211 has round pins.
                 

                Can you buy a 20m 954 camper set

                You can purchase a 955RW, BALS211 + 56CR310 + flex

                What is the replacement for LA1EN11?

                LA1KN11  is the replacement code.

                NOTE: new commercial reference found might not be an exact match

                In regards to LAD5C11 LAD5C31 LAD5C12 LAD5C32 What is the maximum kW range that TeSys SoLink can be used with motor starter combination?

                TeSys SoLink is the connection module to connect GV2/GV3 motor circuit breakers to associated contactors and can be used with GV2 / GV3 breakers up to 30kW.
                For more information please visit the Link provided
                https://www.schneider-electric.com.au/australia/en/products-services/offer-updates/news-viewer.page?c_filepath=/templatedata/Content/News/data/en/local/automation_control/general_information/2014/10/20141024_tesys_solink_integration_system.xml

                In regards to LAD5C11 LAD5C31 LAD5C12 LAD5C32 SoLink What is the maximum number of motor starters that can be connected and controlled with each logic controller?

                Each TM3 I/O module is able to monitor and control up to 4 motor starters and up to 56 motor starters can be connected to logic controller.
                For more information aboput this range please Visit the Schneider website on the link provided
                https://www.schneider-electric.com.au/australia/en/products-services/offer-updates/news-viewer.page?c_filepath=/templatedata/Content/News/data/en/local/automation_control/general_information/2014/10/20141024_tesys_solink_integration_system.xml

                In regards to LAD5C11 LAD5C31 LAD5C12 LAD5C32 SoLink , Can TeSys SoLink be used with AC control supply?

                TeSys SoLink is suitable for 24VDC control supply; the TM3 I/O module provides the 24V DC control voltage to the motor starter.
                For more information on this range please visit the Schneider electric web site on the link provided
                https://www.schneider-electric.com.au/australia/en/products-services/offer-updates/news-viewer.page?c_filepath=/templatedata/Content/News/data/en/local/automation_control/general_information/2014/10/20141024_tesys_solink_integration_system.xml

                Can the single pole LA1DN and LADN auxiliary contact module be mounted on the TeSys contactors?

                ISSUE
                Can the single pole LA1DN and LADN auxiliary contact module be mounted on the TeSys contactors?
                PRODUCT LINE
                Auxiliary contacts for the Tesys D line
                ENVIRONMENT
                Tesys D-Line and Tesys F
                CAUSE
                Fit
                RESOLUTION
                These contacts will only fit on the following contactors:
                Front mount only for LC1D40 through LC1D115 devices and LC1D40A - LC1D65A.
                Left side mount only to LC1F contactors
                CTA-ID : 2002751

                What replaces the obsolete LU9BC11?

                Issue:
                The LU9BC11 terminal is obsolete – what replaces it?

                Product Line:
                All Schneider Electric products

                Environment:
                Products sold and used in the United States

                Cause:
                Need to replace the LU9BC11 block

                Resolution:
                This is half of the LUA1C11 auxiliary contact block, it is no longer sold in pieces the entire LUA1C11 block must be ordered.


                Keywords: U line starter, auxiliary contacts, LU9BC11, LUA1C11
                 
                 
                Show More