TeSys SK Power Add on Block, 1 NO Power, 1 NO SignAlling

TeSys SK Power Add on Block, 1 NO Power, 1 NO SignAlling

TeSys SK Power Add on Block, 1 NO Power, 1 NO SignAlling

Item Number: LA1SK10

Retail
$94.24
RRP (Inc. GST)

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

TeSys SK

Product or component type

power add-on block

Sustainable offer status

Green Premium product

Warranty

18 months

Physical

[Ue] rated operational voltage

  • signalling circuit: 690 V AC <= 400 Hz
  • power circuit: 690 V AC 50/60 Hz
    • [Ie] rated operational current

    • 6 A at <= 440 V AC AC-3 for power circuit
    • 12 A (at <55 °C) AC AC-1 for power circuit
      • Standards

      • IEC 60947
      • VDE 0660
      • NF C 63-110
      • BS 5424
        • Product certifications

        • UL
        • CSA
          • Connections - terminals

          • connector 1 cable(s) 0.35-6 mm²flexible with cable end
          • connector 1 cable(s) 0.5-6 mm²flexible without cable end
          • connector 1 cable(s) 1.5-6 mm²solid
          • connector 2 cable(s) 0.35-1.5 mm²flexible with cable end
          • connector 2 cable(s) 0.35-2.5 mm²flexible without cable end
          • connector 2 cable(s) 1.5-4 mm²solid
            • Net weight

              0.022 kg

              IP degree of protection

              IP2x conforming to VDE 0106

              Ambient air temperature for operation

              -20-50 °C

              Ambient air temperature for storage

              -50-70 °C

              REACh free of SVHC

              Yes

              EU RoHS Directive

              Compliant

              Mercury free

              Yes

              RoHS exemption information

              Yes

              China RoHS Regulation

              Product out of China RoHS scope. Substance declaration for your information

              Environmental Disclosure

              ENVPEP111274EN

              Others

              Number of Units in Package 1

              1

              Number of Units in Package 2

              60

              Package 1 Height

              3.7 cm

              Package 1 Length

              5.5 cm

              Package 1 width

              4.3 cm

              Package 2 Height

              15 cm

              Package 2 Length

              40 cm

              Package 2 width

              15 cm

              Unit Type of Package 1

              PCE

              Unit Type of Package 2

              S01

              Device short name

              LA1SK

              Utilisation category

            • AC-1
            • AC-3
              • Poles description

                1P

                Pole contact composition

                1 NO

                Auxiliary contact composition

                1 NO

                [Ith] conventional free air thermal current

              • 12 A (at 55 °C) for power circuit
              • 10 A (at 55 °C) for signalling circuit
                • Irms rated making capacity

                • 66 A at 690 V AC conforming to IEC 60947
                • 66 A at 690 V AC conforming to NF C 63-110
                  • [Icw] rated short-time withstand current

                    50 A 55 °C for power circuit

                    Associated fuse rating

                    10 A gI for signalling circuit conforming to VDE 0660

                    [Ui] rated insulation voltage

                  • 690 V conforming to IEC 60947
                  • 690 V conforming to VDE 0110 group C
                  • 690 V conforming to BS 5424
                  • 690 V conforming to UL 508
                  • 690 V conforming to CSA C22.2 No 14
                    • Tightening torque

                      0.8 N.m - on connector - with screwdriver pozidriv No 1

                      Signalling circuit frequency

                      <= 400 Hz

                      Compatibility code

                      LA1SK

                      Protective treatment

                    • TC conforming to IEC 60068
                    • TC conforming to DIN 50015
                      • Operating altitude

                        2000 m without derating

                        Package 1 Weight

                        27 g

                        Package 2 Weight

                        1.845 kg

                        WEEE

                        The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                        Show all specifications

                        Frequently Asked Questions

                        hide show

                        Why will LA1SK11 adder deck not fit on CA2SK11 relay?

                        Issue:
                        Why will LA1SK11 adder deck not fit on CA2SK11 relay?

                        Product Line:
                        Tesys Relays

                        Environment:
                        All Products

                        Cause:
                        Product Features

                        Resolution:
                        No, LA1SK11 mounts only on the CA2SK20 relay.




                        CTA-ID : 2014524

                        Can the old D-line front mount attachments fit on the new CAD relays?

                        Issue: 
                        Can the old D-line attachments fit the new CAD relays
                         
                        Product Line:
                        IEC Contactors

                        Environment:
                        Tesys D contactors and relays
                         
                        Cause:
                        Using old accessories with new CAD relays

                        Resolution:
                         Yes, the old style front mount latch attachments, timing attachments, and auxiliary contacts will mount on the new Tesys D-line relays.

                        What is the replacement for a LA6DK10B

                         Part code is LAD6K10B

                        Why does my other equiptment trip when my contactor releases?

                        The colapsing coil voltage on DC is causing a Back EMF (electro magnetic field) issue. This is solved with either a varistor LA4SKE1E or a Diode LA4SKC1U on the LP1K09 contactor.

                        For further information please visit https://www.clipsal.com/Trade
                         

                        What is the replacement for LA1DN20 Contact Block?

                        The replacement for LA1DN20 Contact Block is LADN20


                        LADN20 
                        TeSys D - auxiliary contact block - 2 NO - screw-clamps terminals 
                        For more information see; https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=LADN20

                        Can the single pole LA1DN and LADN auxiliary contact module be mounted on the TeSys contactors?

                        ISSUE
                        In which contactors can the LA1DN and LADN auxiliary contacts be mounted?

                        PRODUCT LINE
                        Auxiliary contacts for the Tesys D line

                        ENVIRONMENT
                        Tesys D-Line and Tesys F

                        RESOLUTION
                        These contacts will only fit on the following contactors:
                        Front mount only for LC1D40 through LC1D115 devices and LC1D40A - LC1D65A.
                        Left side mount only to LC1F contactors
                        Show More