Specifications

Design

Product brand

Clipsal

Range of product

Blue Point

Product or component type

link bar

Physical

[In] rated current

100 A

[Ue] rated operational voltage

500 V

Connector type

screw terminals

EU RoHS Directive

Compliant

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

Product out of China RoHS scope. Substance declaration for your information

Others

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Weight

52 g

Package 1 Height

14 mm

Package 1 width

14 mm

Package 1 Length

62 mm
Show all specifications

Frequently Asked Questions

hide show

What is the difference in handle length on a LAL36400MB vs a LAL36400?

Issue:  
What is the difference between LA36400 and LA36400MB?  

Product Line:  
Molded Case Circuit Breakers  

Environment:  
Legacy LA, LAL, LH, LHL circuit breakers  

Resolution:  
The MB breaker has a shorter handle, so that it will not interfere with the door closing on a panel.  

Note:  
The MB suffix has a handle that is .325 inches shorter than the standard handle.  

How to program an ATV18 drive for 2 wire control and low speed as speed reference?

Issue:
ATV18 driveset up for 2 wire control and low speed as speed reference.

Product Line:
ATV18, Altivar 18.

Environment:
All.

Cause:
Programming and setup.

Resolution:
2 wire control for ATV18 drive will be between LI1 and +24V terminals.  A maintained dry contact or a jumper can act as a run command. 
Low speed can be used to control the drive locally. 
The low speed parameter can be programmed by hitting down arrow key on the drive until LSP is shown. 
Once LSP shows up press data and use the up and down arrow keys to adjust setting.  Once satisfied with speed press enter to save the setting. 

Video: How do you remove the bottom cover on the ATV61 and ATV71?

Issue:
Removal of bottom cover on ATV61 and ATV71.

Product Line:
Altivar ATV61 and ATV71 LHP units only or under 90KW

Environment:
All

Cause:
They can not get the the bottom cover off to check the power terminals.

Resolution:
1st Turn off all power make sure the drive is not powered up and the DC bus is discharged before starting.
You will need to turn the set screw counter clockwise on the control terminal pod.  Next use a flat head screw drive to pry the corners on each side the cover to see if you can work it loose.  Then pull  down cover to remove it.

This procedure is demonstrated in the video below:

Where can I find a copy of the ATV61 Installation Manual?

Issue:
Installation manual needed for an Altivar 61 Drive

Product line:
Altivar 61

Environment:
All models, all serial numbers

Cause
Installation manual is not shipped with the drive.

Resolution:
There are two Installation manuals for the ATV61 drives, Low HP (up to 100HP) and High HP (above 100HP).

The installation manual for the Altivar 61 drives up to and including 100 Horsepower can be found at this link: https://www.schneider-electric.us/en/download/document/1760643/
The installation manual for the Altivar 61 drives above 100 Horsepower can be found by following this link: https://www.schneider-electric.us/en/download/document/1760655/

How is an Altivar VFD set to always run a particular speed when no reference input is connected?

Issue:
Wants the Altivar VFD set to always run at a particular speed when no reference input is connected.

Product Line:
Altivar 12, 32, 312, 61, 71, 212, 320

Environment:
All models

Cause:
VFD does not run the motor without a speed reference.

Resolution:
If there is no external speed reference when the VFD gets a run command, then it will always run at the minimum speed programmed to the VFD.  Set the minimum speed parameter to the desired run speed.  Use parameter LSP for the Altivar12, 32, 312, 320, 61, 71 drives.  Use parameter LL for the Altivar 212 drive.  These can be adjusted while the motor is running.

What does the "pedestal" setting on ATV61 & ATV71 do and how do I program it?

Issue:
Meaning and configuration of "pedestal" option on ATV61/71.

Product Line:
Altivar 61, Altivar 71 series drives.

Environment:
All models, All serial numbers

Cause:
Clarification of this setting is needed by the customer.

Resolution:
The "Pedestal" setting is an option of the Reference Template parameter, and can be found under menu 1.5, Inputs / Outputs configuration.

With Reference Template set to Standard (factory default), the input frequency reference will adjust the motor speed between the LSP parameter and the HSP parameter. With Reference Template set to "Pedestal" the input frequency reference will adjust the motor speed between 0 Hz. and HSP parameter

Example: Low Speed = 30 Hz, High Speed = 60Hz. Input speed reference is 0-10V on AI1 terminal.

With Reference Template set to Standard, the motor will run at 30Hz when the input speed reference is 0V and will increase in speed as the input speed reference increases. If the 0-10V speed input is 5.0 volts (50%) then the speed of the motor will be 50% between LSP (30Hz.) and HSP (60Hz.) or 45Hz.

With Reference Template set to Pedestal, the motor will run at 30Hz. (50% of 0-60Hz) until the 0-10V speed reference reaches 5.0V (50% of 0-10V) and will then start to increase in speed as the speed reference rises above 50%.

Essentially, Reference Template determines whether the low end of the frequency reference is in relation to 0.0Hz, or in relation to the Low Speed Setting.