link active 6hole

Max 4 Neutral Active Meter Links, 6 Hole Active Link

Catalogue Number: L6R
link active 6hole
Retail
$51.37
RRP (Inc. GST)

Specifications

hide show
Product brand
Clipsal
Range of product
Blue Point
Product or component type
active link
Cable cross section
16-16 mm²
[In] rated current
100 A
[Ue] rated operational voltage
500 V
Connector type
screw terminals
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Weight
72 g
Package 1 Height
55 mm
Package 1 width
70 mm
Package 1 Length
46 mm
EU RoHS Directive
Compliant
Mercury free
Yes
RoHS exemption information
Yes
China RoHS Regulation
Product out of China RoHS scope. Substance declaration for your information

Frequently Asked Questions

hide show

Why do you not see the LFr parameter to control in keypad mode and has Altivar ATV16 with keypad VW3A16102?

Issue: Why do you not see the LFr parameter to control in keypad mode and has Altivar ATV16 with keypad VW3A16102?
 
Product Line: ATV16
 
Environment: All
 
Cause: No LFR parameter
 
Resolution: The LFr parameter does not appear if the keypad part number VW3A16102 (which is required) datecode is before 9422.


 

Is there a way to store the Lfr setting after power is recycled on the Altivar ATV16?

Issue:
Is there a way to store the Lfr setting after power is recycled on the Altivar ATV16?
 
Product Line:
ATV16
 
Environment:
All
 
Cause:
N/A
 
Resolution: 
You can run the drive in Terminal mode, jumper +10 to AIV and then adjust HSP parameter to control the speed. This will work similar to adjusting Lfr except the value will be stored after power is recycled which can not be done in LFR parameter which reverts back to zero when cycle power.


 

What is the maximum DC voltage per pole for TeSys F Range contactors.

The maximum DC voltage for TeSys F range contactors is 125 Volt per pole. This voltage is applicable for the specification of L/R <= 15ms in DC applications.

What is the maximum DC voltage per pole for TeSys D range contactors.

The maximum DC voltage for TeSys D range contactor is 75 Volt per pole. This voltage is applicable for the specification of L/R <= 15ms in DC applications.

What is the scaling unit for ATV600 motor current (LCR) parameter?

When reading the value of LCR parameter using Modbus the scaling unit varies as follows:  
  • 0,01 for all sizes below or equal to 15KW 
  • 0,1A between 18,5 to 160KW 
  • 1A over 160KW 

 

Why will the Altivar ATV16 not run when set up for local mode?

Issue: Why will the Altivar ATV16 not run when set up for local mode?
 
Product Line: ATV16
 
Environment: All
 
Cause: Not running in local
 
Resolution: Verify Fwd command and correct switch positions as well as verify reference frequency. Need to set LFr to the required setting.


 

What can cause an ULF motor underload fault on the ATS48 soft starter?

Issue:
What can cause an ULF motor underload fault on the ATS48 soft starter?

Product Line:
Altistart ATS48

Environment:
All

Cause:
The soft starter is programmed to for activation motor underload (ULL) in the Pr0 menu.
The motor underload threshold parameter (LUL) is set to 60% and the drive is running only 58% or lower motor torque viewed in the SUP menu parameter (Ltr).

Resolution:
Troubleshooting:
Check Motor underload threshold parameter (LUL) in menu PrO and compare it the motor torque parameter in the SUP menu.   If your LUL parameter is set lower then the Ltr in the SUP then the soft starter will trip on ULF fault.

How do you set up the Altivar 28 drive so the start / stop / speed are controlled by the remote keypad?

Issue:
How do you set up the Altivar 28 drive so the start / stop / speed are controlled by the remote keypad?

Product Line:
Altivar 28

Environment:
All

Cause:
N/A

Resolution:
Go to the I/O ( input / output ) menu and set LCC ( local control) to Yes which no allows acces to LFR ( local frequency) parameter for local speed adjustment.  
To change the reference setting you will need to go to the SET menu and change parameter LFR each time desire to change the speed the drive is commanded to run at..

What are the specifications on R1 and R2 Relays for ATV61 or ATV71 Drives?

Issue:
what are the specifications on R1 and R2 Relays for ATV61 or ATV71 Drives?

Product Line:
ATV71, ATV61, Altivar 61, Altivar 71

Environment:
All

Cause:
NA

Resolution:
R1A  N/O contact
R1B  N/C contact
R1C  Common point C/O contact of programmable relay R1
R2A  N/O contact
R2C  Common Point C/O contact of programmable relay R2

• Minimum switching capacity: 3 mA for 24 Vdc
• Maximum switching capacity on resistive load:
5 A for 250 Vac or 30 Vdc
• Maximum switching current on inductive load (cos ϕ = 0.4 L/R = 7 ms):
2 A for 250 Vac or 30 Vdc
• Reaction time: 7 ms ± 0.5 ms
• Service life: 100,000 operations at max. switching power

How is the ATV312 default display changed to show a different monitored parameter?

Issue:
How is the ATV312 default display changed to show a different monitored parameter?

Product Line:
ATV312  ATV31

Environment:
All

Cause:
Preference is to normally display a parameter such as motor current or motor torque, not the factory default of output frequency.

Resolution:
Go to SUP menu and display the parameter to be used as a default display ( e.g. LCr or Otr ).  Press ENT once to show the current value of that parameter.  Then press and hold ENT for about 2 seconds and the display will flash, indicating the process is complete.

How do you display motor current on the ATV312 drives?

Issue:
Display motor current on the ATV312 drives

Product Line:
Altivar ATV312

Environment:
All

Cause:
Needs to display motor current on the main display.

Resolution:
Programming
SUP menu
Enter
Arrow down to LCR enter
now the drive will display motor current. 
If you want the drive to always show motor current hit Enter again.

Why does the motor rated current value for ATS22 in Somove not show correct value?

Issue:
Using ATS22 with SoMove: Does not show the accurate "Motor Rated Current." and changed the In setting and it reverts back to the original setting in SoMove.

Product Line:
ATS22

Environment:
SoMove

Cause:
Not showing the correct values on the SoMove printout

Resolution:
This is result of the Altistart DTM library being out of date.  Please download and update the catalog withing SOmove.  
The customer needs to update their DTM library to V12.0 minimum.
Show More