Quantcast

Clipsal - Max 4 Mini Neutral link 100 A 500 V 6 hole with cover front wiring Black

Clipsal - Max 4 Mini Neutral link 100 A 500 V 6 hole with cover front wiring Black

Clipsal - Max 4 Mini Neutral link 100 A 500 V 6 hole with cover front wiring Black

Item Number: L6

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range

MAX9

Product brand

Clipsal

Range of product

Blue Point

Product or component type

neutral link

Physical

[In] rated current

100 A

[Ue] rated operational voltage

500 V

Connector type

screw terminals

REACh Regulation

Reference contains Substances of Very High Concern above the threshold

EU RoHS Directive

Compliant

Mercury free

Yes

China RoHS Regulation

Product out of China RoHS scope. Substance declaration for your information

RoHS exemption information

Yes

Others

Package 1 Bare Product Quantity

1

Cable cross section

16 mm²

Number of mounting holes

6

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Height

5.5 cm

Package 1 Width

2.7 cm

Package 1 Length

7 cm

Package 1 Weight

72 g

Unit Type of Package 2

BB1

Number of Units in Package 2

10

Package 2 Height

7 cm

Package 2 Width

13.5 cm

Package 2 Length

22.2 cm

Package 2 Weight

0.792 kg

Unit Type of Package 3

CAR

Number of Units in Package 3

100

Package 3 Height

26.5 cm

Package 3 Width

24.6 cm

Package 3 Length

40.2 cm

Package 3 Weight

8.194 kg
Show all specifications

Frequently Asked Questions

hide show

How to change a wrong USB Driver on DCCABKIT6 

Suppose the following happens when connecting the DCCABKIT6 cable between Laptop and DALIcontrol Duo Mode 3 Power Supply (DCDALCIP250-2).

In Device Manager find something like

1

The cable has likely been used with some other product that has recognised the FDTI chip and installed this LibUSB driver which is not recognised by the Simple Wizard which sees a different device ID

BEFORE GOING FURTHER REALISE THAT ONCE COMPLETE THE OTHER DEVICE WILL NO LONGER FIND ITS REQUIRED DRIVER.

Right click on this entry in the Device Manager and select Properties from the menu

2

And proceed to the Driver tab

 3

…and select <Update Driver>

 4

… and Select <Browse my computer for Drivers>

 5

Select <Let me pick from a list of available drivers on my computer>

With this next Dialog un-tick the Show compatible hardware

 6

In this case you should see Manufacturer FTDI and Select from the Model USB Serial Port which should start the install finishing with…

 7

From here you should now be able to connect.

It is important to note that when connecting to the DALIcontrol Duo Mode 3 Power Supply (DCDALCIP250-2) with the DCCABKIT6 programming cable and running DCBMWizard or SimpleWizard that the power supply be in mode 1. To achieve this on the DCDALCIP250-2 press and hold the <ON A> button and momentarily press the <TEST A> button. The Line A indicator will single pulse 5x to indicate the mode.

 

If there is a compatible driver installed you can try tick Show Compatible hardware, then try selecting one of the drivers below.

8

If there are no drivers to be found on the Computer in question it is then possible to download the software by going to the following on  your web browser https://support.arduino.cc/hc/en-us/articles/4411305694610-Install-or-update-FTDI-drivers and follow the instructions laid out.

Also go to https://ftdichip.com/drivers/  and follow up with https://ftdichip.com/document/installation-guides/


 

Video: How to Import MiCOM Data Models

Product Line
Easergy or MiCOM S1 Studio

Environment   
MiCOM configuration

Resolution
How to Import a Data Model. Review the video below and the step by step instructions that follow.

    • Open the Data Model Manager

      • a. Start > All Programs > Schneider Electric > MiCOM S1 Studio (Easergy Studio) > Data Model Manager
        b. Follow the screen shots below or the attached video:

      ImportSelect File
      Next
      Select which to import
      Click Import
      Import Finished
      Close
       

GeoSCADA Server with Embedded ViewX Client License Activation

The following two steps will enable your Geo SCADA server along with the accompanying ViewX Client that is embedded within the server for usage on the same host machine as the server. Please note that the embedded ViewX client within the server needs to be activated separately using the same license file.

Step One – Server Activation:
 
  • Save the attached License File onto your computer (It is suggested that you save your license file in the same folder as the Geo SCADA installation)
  • Start the Geo SCADA server using the Service Manager or by right clicking the server icon in the bottom right of the screen and selecting Start Server.
GS Service Manager
  • Right click on the server icon and select ‘License Details’ from the pop-up menu to view the following window:
License Details
  • Click Change to browse to the license file that was provided by the TRSS licensing team and saved to your hard drive per previous instructions.
  • Select file and click open:
  • Double check that license features such as point size, web client and/or applicable drivers are listed in their respective fields.
Please note: the ‘0’ within the ViewX client field is a default setting that will not affect the enabling of the embedded ViewX client in the upcoming section. If server side floating ViewX clients have been purchased for Geo SCADA, this is where the purchased quantity will appear.

Step Two – Embedded ViewX Client Activation:

Important Note - Before proceeding with the following procedure, please ensure that the ViewX client is closed.
  • Click the Windows Start Menu, highlight EcoStruxure Geo SCADA and select Configure Connections.
  • The Geo SCADA ‘Client Dialog’ will appear - Click on the ‘Licenses’ button:
Configure Connections > Licenses
  • The following screen will appear:
Client Licensing
  • Click the browse button (… right of the license file field) and browse to the same file used to activate the server in the previous step.
  • Select file and click open.
  • Click on “Apply” and then click “Refresh”. The license should now show as valid.
  • Click on the OK button and close the ‘Client Licensing’ dialog.
  • (Re)start the ViewX client by clicking the ViewX icon on your desktop.
If at this point you are receiving an error message stating “insufficient licenses available for client” you want to make sure that your Geo SCADA Client Configurator has the “Use Client Licensing” option showing a checkmark.

Use Client Licensing
 
 

How to download the firmware files from se.com (global page)?

First, you need to find the product page! I.e 5500NAC2

 

  1. Type in the commercial reference in the search bar, and once the product you are looking for pop-up, click on the product bar.

 5500NAC2 1

 

  1. Once on the product page, scroll down, pass Main Documents > Specifications > Documents, and reach the Software and Firmware section at the bottom.

 5500NAC2 2

 

  1. Select “Firmware” for the latest version in the Document type section, or if you are looking for previous firmware files, you can see them under “Firmware – History and others”.

 5500NAC2 3

  1. You can download the firmware, release notes, and user manual separately OR as a whole in zip format.

Can the Phaseo DC power supplies be back fed to go from DC to AC?

Issue:
Looking for a transformer or power supply to convert DC to AC

Product Line:
Phaseo ABL8 Power Supply

Environment:
Phaseo Power Supply

Cause:
Will backfeeding an ABL8 DC power supply allow DC voltage to convert to AC?

Resolution:
No, these are not intended to be used in this manner.  A DC rectifier will need to be used

Video: Where is the wiring diagram located and what information does it contain and where is the date code located on ALL the molded case circuit breaker enclosures?

Issue:
Product Design Features

Product Line:
Circuit Breaker Enclosures

Resolution:
NOTE: This information will generally apply to ALL the Molded Case Circuit Breaker Enclosures(The F-frame, B-Frame, H-frame, the J-frame, the L-frame, the M-frame and P-Frame). But for the video a J250S was used.




The wiring diagram on the circuit breaker enclosures will be located on, one of the inside sidewalls of the enclosure. All the necessary information for the enclosure will be on the wiring diagram and will contain the following;
1) Catalog and series number of the enclosure
2) What type of Circuit breakers that can be used
3) Any accessory that can be used in the enclosure, like the solid neutral and equipment ground kit
4) The UL listed catalog number Prefixes for the breakers that can be used in the enclosure
5) Maximum wire sizes for the enclosure(NOTE: Sometimes the breaker can accept larger wire, BUT the enclosure wire bending space will be limited to what the wiring diagram shows)
6) The Wiring schematics
7) The Short Circuit Current Rating information for each breaker at each voltage level
8) The Date code. The date code will be an ink stamp, generally located on the inside back wall of the enclosure. The Date Code will be a 5 or 6 digit code and will read as follows; first two digits = year, the 2nd two digits = week of the year, the 5th digit = the day of the week and the last digit(if used) = the shift. For example, 183241 is year - 2018, week of year -32, day of week - 4 and shift - 1. (Aug. 9th, 2018)
Show More