link active 5hole

Max 4 Neutral Active Meter Links, 5 Hole

Catalogue Number: L5R
link active 5hole
Retail
$64.82
RRP (Inc. GST)

Specifications

hide show
Product brand
Clipsal
Range of product
Blue Point
Product or component type
active link
Cable cross section
16-16 mm²
[In] rated current
100 A
[Ue] rated operational voltage
500 V
Connector type
screw terminals
REACh Regulation
Free of Substances of Very High Concern above the threshold
EU RoHS Directive
Compliant
Mercury free
Yes
RoHS exemption information
Yes
China RoHS Regulation
Product out of China RoHS scope. Substance declaration for your information

Frequently Asked Questions

hide show

Why can't Vijeo Designer import my RSLogix L5K file? It says I am missing software.

When importing RSLogix L5K files in Vijeo Designer, ensure that the Microsoft .NET Framework 3.5 SP1 is installed.

Which Driver do I need to select to link my Vijeo Designer V6.2 variables to the RSLogic 5000 l5k file?

The driver to select is Allen-Bradley Ethernet/IP.

Then right-click on variables and link to the L5k file.

.

Does Vijeo Designer V6.2 supports linking to an L5K file from RSLogix5000 V28?

Vijeo Designer V6.2 SP4 Native Ethernet/IP driver can link to a L5K file created by RSLogix5000 V28.

Why do you not see the LFr parameter to control in keypad mode and has Altivar ATV16 with keypad VW3A16102?

Issue: Why do you not see the LFr parameter to control in keypad mode and has Altivar ATV16 with keypad VW3A16102?
 
Product Line: ATV16
 
Environment: All
 
Cause: No LFR parameter
 
Resolution: The LFr parameter does not appear if the keypad part number VW3A16102 (which is required) datecode is before 9422.


 

Is there a way to store the Lfr setting after power is recycled on the Altivar ATV16?

Issue:
Is there a way to store the Lfr setting after power is recycled on the Altivar ATV16?
 
Product Line:
ATV16
 
Environment:
All
 
Cause:
N/A
 
Resolution: 
You can run the drive in Terminal mode, jumper +10 to AIV and then adjust HSP parameter to control the speed. This will work similar to adjusting Lfr except the value will be stored after power is recycled which can not be done in LFR parameter which reverts back to zero when cycle power.


 

What version of Rockwell RSLogix5000 .L5K files are supported for Symbol Link in Vijeo XD v3.0?

Issue
What version of Rockwell RSLogix5000 .L5K files are supported for Symbol Link in Vijeo XD v3.0?

Product Line
Vijeo XD v3.0

Environment
Windows PC Configuration Software

Resolution
Rockwell RSLogix5000 .L5K symbol files that are supported in Vijeo XD v3.0 are:
version 13, 15, 16, 17, 18, 19, 20, and 21

Note:  FS, LS, OV, and ER of TIMER Predefined types are not supported.

How do you import the tags from the RSLogix5000 L5K file in Vijeo Designer using the Link Variables feature?

Issue
How do you import the tags from the RSLogix5000 L5K file in Vijeo Designer using the Link Variables feature?
 
Product Line
Vijeo Designer

Environment
Configuration software in Windows PC

Resolution
From RSLogix5000, you will need to re-save the project file as a L5K file format. By going to the File menu and select Save As..


From the SaveAs window, create a path and file name of where you want to save the file. Make sure you select L5K as the file type then select Save


In Vijeo Designer, create the Rockwell Ethernet IP native driver. In this example, I am using the CompactLogix PLC. But you need to select the controller you are using.



Input the IP address


<right-click> on the Variables node and select Link Variables.


From the Link Variables window, locate the path of the L5K file that you have saved. Select File of Type as Rockwell L5K Files and EQUIPMENT name of the EIP driver you have created then select OK.


From the New Variables from EQUIPMENT, select the tags you want to import into Vijeo Designer. Under the When adding variables: option, select how you want to save the tag names and select add.


Once the link variables are complete, you will see all of the variables you have imported in the variable editor window.

 

What is the maximum DC voltage per pole for TeSys F Range contactors.

The maximum DC voltage for TeSys F range contactors is 125 Volt per pole. This voltage is applicable for the specification of L/R <= 15ms in DC applications.

What is the maximum DC voltage per pole for TeSys D range contactors.

The maximum DC voltage for TeSys D range contactor is 75 Volt per pole. This voltage is applicable for the specification of L/R <= 15ms in DC applications.

What is the scaling unit for ATV600 motor current (LCR) parameter?

When reading the value of LCR parameter using Modbus the scaling unit varies as follows:  
  • 0,01 for all sizes below or equal to 15KW 
  • 0,1A between 18,5 to 160KW 
  • 1A over 160KW 

 

Why will the Altivar ATV16 not run when set up for local mode?

Issue: Why will the Altivar ATV16 not run when set up for local mode?
 
Product Line: ATV16
 
Environment: All
 
Cause: Not running in local
 
Resolution: Verify Fwd command and correct switch positions as well as verify reference frequency. Need to set LFr to the required setting.


 

What can cause an ULF motor underload fault on the ATS48 soft starter?

Issue:
What can cause an ULF motor underload fault on the ATS48 soft starter?

Product Line:
Altistart ATS48

Environment:
All

Cause:
The soft starter is programmed to for activation motor underload (ULL) in the Pr0 menu.
The motor underload threshold parameter (LUL) is set to 60% and the drive is running only 58% or lower motor torque viewed in the SUP menu parameter (Ltr).

Resolution:
Troubleshooting:
Check Motor underload threshold parameter (LUL) in menu PrO and compare it the motor torque parameter in the SUP menu.   If your LUL parameter is set lower then the Ltr in the SUP then the soft starter will trip on ULF fault.
Show More