link bar only 5hole neutral

Max 4 Neutral Active Meter Links, 5 Hole Bar Only

Catalogue Number: L5P
link bar only 5hole neutral
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Product brand
Clipsal
Range of product
Blue Point
Product or component type
link bar
[In] rated current
100 A
[Ue] rated operational voltage
500 V
Connector type
screw terminals
REACh Regulation
Free of Substances of Very High Concern above the threshold
EU RoHS Directive
Compliant
Mercury free
Yes
RoHS exemption information
Yes
China RoHS Regulation
Product out of China RoHS scope. Substance declaration for your information

Frequently Asked Questions

hide show

Do we do the Lup adaptor ?

no it is now discontinued
LUP_ADAPTOR

How to Write Workbench I5P File into SCADAPack E-Series RTU?

How to Write Workbench I5P File into SCADAPack E-Series RTU?

The I5P file is a package containing the files needed to load the project. The I5P file is located in the project folder.
Please follow below steps to write I5P application file to the RTU:


1- You will find the I5P file in a subfolder has the same name on your Workbench project, If you didn’t find the I5P file in the project, build the project from the project level or the solution level to generate the network configuration files.



2- Make sure the Device is connected then and the logic is Cleared before you go to IEC 61131-3 and select Write Application



3-Browse your local disk to get I5P location then Click Open          



4- A confirmation message like below will pop-up



6- Refresh IEC-61131-3 for the Application Status page

Why can't Vijeo Designer import my RSLogix L5K file? It says I am missing software.

When importing RSLogix L5K files in Vijeo Designer, ensure that the Microsoft .NET Framework 3.5 SP1 is installed.

Part number for a C clip to suit prestige range?

The part name is 154/2

Which Driver do I need to select to link my Vijeo Designer V6.2 variables to the RSLogic 5000 l5k file?

The driver to select is Allen-Bradley Ethernet/IP.

Then right-click on variables and link to the L5k file.

.

Does Vijeo Designer V6.2 supports linking to an L5K file from RSLogix5000 V28?

Vijeo Designer V6.2 SP4 Native Ethernet/IP driver can link to a L5K file created by RSLogix5000 V28.

What is the difference in handle length on a LAL36400MB vs a LAL36400?

Issue:  
What is the difference between LA36400 and LA36400MB?  

Product Line:  
Molded Case Circuit Breakers  

Environment:  
Legacy LA, LAL, LH, LHL circuit breakers  

Resolution:  
The MB breaker has a shorter handle, so that it will not interfere with the door closing on a panel.  

Note:  
The MB suffix has a handle that is .325 inches shorter than the standard handle.  

What version of Rockwell RSLogix5000 .L5K files are supported for Symbol Link in Vijeo XD v3.0?

Issue
What version of Rockwell RSLogix5000 .L5K files are supported for Symbol Link in Vijeo XD v3.0?

Product Line
Vijeo XD v3.0

Environment
Windows PC Configuration Software

Resolution
Rockwell RSLogix5000 .L5K symbol files that are supported in Vijeo XD v3.0 are:
version 13, 15, 16, 17, 18, 19, 20, and 21

Note:  FS, LS, OV, and ER of TIMER Predefined types are not supported.

How do you import the tags from the RSLogix5000 L5K file in Vijeo Designer using the Link Variables feature?

Issue
How do you import the tags from the RSLogix5000 L5K file in Vijeo Designer using the Link Variables feature?
 
Product Line
Vijeo Designer

Environment
Configuration software in Windows PC

Resolution
From RSLogix5000, you will need to re-save the project file as a L5K file format. By going to the File menu and select Save As..


From the SaveAs window, create a path and file name of where you want to save the file. Make sure you select L5K as the file type then select Save


In Vijeo Designer, create the Rockwell Ethernet IP native driver. In this example, I am using the CompactLogix PLC. But you need to select the controller you are using.



Input the IP address


<right-click> on the Variables node and select Link Variables.


From the Link Variables window, locate the path of the L5K file that you have saved. Select File of Type as Rockwell L5K Files and EQUIPMENT name of the EIP driver you have created then select OK.


From the New Variables from EQUIPMENT, select the tags you want to import into Vijeo Designer. Under the When adding variables: option, select how you want to save the tag names and select add.


Once the link variables are complete, you will see all of the variables you have imported in the variable editor window.

 

Do you have a 45 pole plastic enclosure that is flush mount?

Yes, there is a 45 pole plastic flush mount board. The part number is 4FCC45-WE.

Some of the key features are:
  • Supplied with neutral and earth bars
  • 15 module Jetstrea m
  • No isolating switch
  • Ample wiring entries
For further information please view the attached document or visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=4FCC45
 

 

Where can I find a copy of the ATV61 installation manual?

Issue:
 Installation manual needed for an Altivar 61 drive.

Product line:
Altivar 61

Environment:
All models, all serial numbers

Cause
Installation manual is not shipped with the drive.

Resolution:
There are two Installation manuals for the ATV61 drives, Low HP (up to 100HP) and High HP (above 100HP).

The installation manual for the Altivar 61 drives up to and including 100 Horsepower can be found at this link: https://www.schneider-electric.us/en/download/document/1760643/

The installation manual for the Altivar 61 drives above 100 Horsepower can be found by following this link: https://www.schneider-electric.us/en/download/document/1760655/

How to program an ATV18 drive for 2 wire control and low speed as speed reference?

Issue:
How to program an ATV18 drive for 2 wire control and low speed as speed reference?

Product Line:
ATV18, Altivar 18.

Environment:
All.

Cause:
Programming and setup.

Resolution:
2 wire control for ATV18 drive will be between LI1 and +24V terminals.  A maintained dry contact or a jumper can act as a run command. 
Low speed can be used to control the drive locally. 
The low speed parameter can be programmed by hitting down arrow key on the drive until LSP is shown. 
Once LSP shows up press data and use the up and down arrow keys to adjust setting.  Once satisfied with speed press enter to save the setting. 

Show More