hide show

What is the default Password for a Zelio Smart Relay?

The Zelio do not have a default password. A Firmware download will recover the Zelio but it will also clear the program.

Is cover available for part number 753R?

No.Cover is not available for this part.

Video: How to recover the system on the HMIGTU Series?

Issue:
Video: How to recover the system on the Magelis HMIGTU Series?
 
Product Line:
Magelis HMIG5U, HMIG5U2, HMIG3U, HMIG3X
 
Resolution:
The goal of this resolution is to provide the system recovery resource that can be used to backup and recover the Magelis HMIG3U, HMIG3X, HMIG5U and HMIG5U2. All the HMIGTU (except HMIG2U) series have their firmware stored on a System CFast or System SD Card.
 
1) Power off the HMIGTU.
2) Remove the System CFast or System SD card from the HMIGTU (this SD card slot is labeled "SYSTEM CARD" on the outer casing of the HMI).
3) Insert the CFast or System SD into a CFast (Type 1.0) or SD Card Reader on your office PC.
4) Launch the Backup Recovery Tool (BackupRecovery.exe).
5) In the "File Name" field, choose the recovery image file (.bin) for your type of HMIGTU.
6) Select the Drive Letter from the dropdown list to match that of your CFCard or SD Card that you inserted.
7) Click "Recovery" and then [Yes] when you are prompted to continue this process
8) The .bin image will be written to the CFast or SD card. Please wait and do not remove the CFast or SD Card during this time.
9) Once the process is done, a message will appear "Quit he application, and eject the disk from the PC."
10) Eject the Cfast or SD card from your PC
11) Insert it back into the HMIGTU's system slot (the one close to the screen-mount side)
12) Power on the HMIGTU as per normal.
 
 
Attached are:
Backup Recovery Tool - "BackupRecovery.exe"
Backup Recovery User Manual - "Backup Recovery User Manual.pdf"
 
 
You can also find an pre-made recovery image file that will reset the HMIG3U back to V6.2 SP3.1 state here:

 

How to recover historical data on an ION meter?

With ION Setup you can configure Data Logging of the ION7550, as per page 161 of the attached user guide.

The logging setting can be adjusted via three areas Memory, Revenue Log, and EnergyDemand Log.

It further explains on page 170 viewing log for various options.

If you haven't setup Data Logging already in ION Setup the above option may not work.

 

What are the encoder option cards for the ATV71 drive?

Issue:
Encoder option cards for the ATV71 drive.

Product Line:
Altivar 71, ATV71

Environment:
All

Cause:
Encoder feedback requirement

Resolution:
See attached for encoder card options and specifications.

What is the cover plate for the C2032VTB?

The cover plate is a standard 2 gang cover plate, C2032C-xx