link neutral 5hole less cov

Max 4 Neutral Active Meter Links, 5 Hole, Link Less Cover

Catalogue Number: L5A
link neutral 5hole less cov
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Product brand
Clipsal
Range of product
Blue Point
Product or component type
neutral link
[In] rated current
100 A
[Ue] rated operational voltage
500 V
Connector type
screw terminals
Number of poles
1
REACh Regulation
Free of Substances of Very High Concern above the threshold
EU RoHS Directive
Compliant
Mercury free
Yes
RoHS exemption information
Yes
China RoHS Regulation
Product out of China RoHS scope. Substance declaration for your information

Frequently Asked Questions

hide show

How many mounting inches are needed for an I-LINE Powerpact L frame?

Product Line:
Circuit Breakers

Environment:
Powerpact L, I-line version

Resolution:
The I-line version of the Powerpact L Circuit Breaker requires 6 inches of bus. This is sometimes referred to as the "mounting inch requirement".

Is there going to be a 45A cooker switch in 40M? Been asked for 75A

There is not a specific 45A mech - it comes assembled as a complete switch plate in Iconic range.

PDL647 - double pole 45A rated - is this 45A per pole, or 45A combined?

45A per pole

What is the 85A Overload to suit LC1D115* Contactor

85A Overload code for LC1D115* Contactor = LRD4365 

Which maximum current can the tap off units withstand?

For tap off unit reference n°04151 => In: 35A (6²) et 45A (10²) at 40°C
For tap off unit reference N°04152 => In: 55A (16²) at 40°C

 The current is limited by the cage terminal not by the cable cross section.


Legacy KB System (APS) Data: RESL196279 V2.0, Originally authored by SeOs on 12/31/2008, Last Edited by GwPo on 06/25/2010
Related ranges: Prisma Plus

What is the part code for a Slimline 45A range switch for induction hob

There is no 45A inductive rated switch within the Slimline Range

Is there a 35A double pole mechanism?

No. We have 30M35 which is 1 pole, 35A mech.

Why can't Vijeo Designer import my RSLogix L5K file? It says I am missing software.

When importing RSLogix L5K files in Vijeo Designer, ensure that the Microsoft .NET Framework 3.5 SP1 is installed.

Do our LC1D09 to 65A contactors come with NO & NC aux contacts

 Yes they come with both and they are rated at 10A 

What is the AC3 rating of a PDL 56SW363/2

The AC3 rating is 18.5kw, 35A

Do you have a 35A mech that says hot plate?

Yes, we do have a 35A mech that says hot plate. 

The part number is 30M35-HPLATE.

For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=30M35-HPLATE.

What are the red safety covers for the TeSys D LC1D contactors?

Issue:
What is the  red safety covers for D line contactor.

Product Line:
D-Line IEC contactors 

Environment:
IEC Contactors  sold and used in the United States

Cause:
Requirement for safety covers in specific situations

Resolution:
LAD9ET1S for 9A to 65A contactors.
LAD9ET3S for 80A to 95A contactors.
LAD9ET4S for 110A to 150A contactors.
There are also auxillary contacts available for front mount with a ref cover, model LADN22S, 2NO + 2NC
Show More