Quantcast

C-Bus Din Rail Mounted Analogue Output Unit, 4 Channel, 240V

C-Bus Din Rail Mounted Analogue Output Unit, 4 Channel, 240V

C-Bus Din Rail Mounted Analogue Output Unit, 4 Channel, 240V

Item Number: L5504AMP

Retail
$986.34
RRP (Inc. GST)

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Product brand

Clipsal

Sustainable offer status

Green Premium product

Physical

REACh Regulation

Free of Substances of Very High Concern above the threshold

REACh free of SVHC

Yes

EU RoHS Directive

Compliant

Toxic heavy metal free

Yes

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

 Pro-active China RoHS declaration (out of China RoHS legal scope)

Environmental Disclosure

ENVPEP111268EN

Circularity Profile

ENVEOLI111254EN

Others

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Weight

292 g

Package 1 Height

10 cm

Package 1 width

11.4 cm

Package 1 Length

16 cm

WEEE

The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Show all specifications

Documents & downloads

hide show
Filter items
  • All

  • Product Brochures

  • CAD Files and Packs

  • Technical Data Catalogues

  • Technical Leaflet

  • Installation Instruction

  • End of Life Manual

  • Specifications

  • Application Solutions

  • Corporate Marketing

  • Software - Release

  • Software - Archive

Frequently Asked Questions

hide show

Can C-Bus operate 0-10V light fittings

Yes, it requires a L5504AMP, and must be used in conjunction with a C-Bus system and can dim 0-10V or 1-10V ballasts.

Output Rating - Sinking: 15mA at Vout = 0V, 8mA at Vout = 10V, i.e. I = 15-(0.7*Vout)mA
Output Rating - Sourcing: 2.5mA (i.e. minimum of 4kΩ)

What is the current rating per channel for an L5504D2UP

The current rating per channel is 2.5A

Is part number L5504D2U suitable for dimming LED?

Yes. The L5504D2U is suitable for LED dimming.

Key Features

  • 4 channel Leading Edge/Trailing Edge
  • 12M DIN modules wide
  • 4 channels of 2.5A rating
  • Suitable for low voltage electronic transformers, incandescent lamps and low voltage lamps with iron core transformersl
  • automatic load sensing
  • software selectable network burden and C-Bus system clock
  • inbuilt 200mA C-Bus power supply
  • C-Bus Learn Enabled
  • for use with Leading Edge or Trailing Edge compatible low voltage transformers
  • 215 mm x 85 mm x 65 mm
for more information, please visit:https://www.clipsal.com/Trade/Products/ProductDetail?catno=L5504D2U

 

What are the C-BUS Relay part numbers?

You have several options for relays, Catalogue numbers and information below.

L5504RVF, L5504RVFP** - 4 Channel voltage free relay - 10amps per channel
L5508RVF, L5508RVFP** - 8 Channel voltage free relay - 10amps per channel
L5512RVF, L5512RVFP** - 12 Channel voltage free relay - 10amps per channel

L5504RVF20, L5504RVF20P** - 4 Channel voltage free relay - 20amps per channel

L5508RELVP - 8 Channel Extra Low Voltage Relay

5101R - Single and Two Channel 250v AC 10amp relay
5102RVF - Single and Two Channel 250v AC 10amp Voltage Free Relay

** Any part number that has a 'P' after the part number for Din Rail mount units does NOT include a C-Bus 200ma Power Supply..

What to do when C-Bus dimmer channel will not turn off ?

- Initially check that the programming is correct.

- If using LED lights, the LED may stay on when the channel is off, this is due to the leakage current being enough to power the LED, use of a 31LCDA may resolve this issue.

- If using Halogen and  the channel will not turn off, there may be damage to the electronics on this channel - Electricians only to perform this check, disconnect the Active's , Neutral and Earth from the unit, remove the cable for the load on that channel then with a multimeter check between the Neutral and that suspect channel output, if you see a low resistance the Triac has shorted.

- Advise not to use this channel and label as faulty, other channels on this dimmer should still be ok to use as per normal, alternatively you could return this unit for a quote on repair, note a repair may not be possible.

What are the C-Bus Channel Limitation for Current Measurement Unit?

There will be limitations on how many CMU channels that can be utilized, depending on the device being used. This is due to memory limitations of those devices, as to how much historical data can be retained.

Below is a list of the maximum CMU Channels that can be used. Each CMU has 4X Channels per unit.
Each CT Coil has a selection range of either 0-40 and 0-80 AMP Range - This is software selectable..
 
DescriptionCMU Channels
Schedule +28
Homegate20
CTC Colour20
PAC4
Wiser  4
B&W/Spectrum4

5504CMU Current Measurement Unit,
Some key features are:
  • Measures and reports over C-Bus a circuit’s instantaneous electrical power consumption
  • Current monitoring is performed via a split core CT (current transformer)
  • 4 channel unit (measure up to 4 electrical circuits per unit)
  • Display energy use on C-Bus 6.4 inch colour touch screen, Schedule Plus, HomeGate Software and Wiser Home Control
  • Raise C-Bus alerts and warning messages based on predefined thresholds
  • Control electrical devices based on predefined thresholds (load shed)
  • Can provide confirmation that electrical devices are operating as expected
  • DIN rail mounted, 4M wide


For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=5504CMU